Council archive · source document
SUPERSEDED Compiled Approved Plans - 51983.3225.23 (As Published)
Plans and drawings: the text below has words only, no drawings.
NOOSA COUNCIL
APPROVED PLAN
51983.3225.22 19 MAY 2025
[OCR of page images]
LEGEND NOTE NOTES NOTE:
COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.
Parwn>
4
q
BOUNDARY
DP coy | | = |COL) |L ~1fpee=
(EXTG,| TEXTS] | —|— ETB
(DEDICATED LOT
EXCLUSIVE USE AREA)
ADJOINING
VILLA
ROADWAY
ay
BOUNDARY,
|
i
BOUNDARY
2. ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
cor) - .
NOTE: DEMOLITION NOTES
ROOM DIMENSIONS DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
SHOWN ARE TO DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING STAIRS AND HANDRAIL.
ADJOINING FINISHED WALL FACES. DEMOLISH EXISTING CONCRETE GROUND SLAB.
| DEMOLISH EXISTING SCREEN STRUCTURES.
VILLA o— —- —_ DEMOLISH EXISTING BRACING FRAMES. NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
BOUNDARY ADJOINING STRUCTURAL ENGINEER TO SUIT NEW WORKS,
— — © - - 7. DEMOLISH EXISTING GROUND PAVERS TO
VILLA EXTENT SHOWN.
| 8. DEMOLISH EXISTING JOINERY BENCH.
p) N 9. REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).
10. REMOVE EXISTING HOT WATER SYSTEM AND
RETAIN FOR REINSTATEMENT.
. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
12. DEMOLISH EXISTING SANITARY FIXTURES
INCLUDING TOILETS, SHOWERS AND BASINS.
13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
\ (CLIENT TO CONFIRM).
wu 14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
| epoe72200mm = +g-l9 SUFFICIENT RECTIFICATION WITH STRUCTURAL
| 5 CONCRETE th"); — — | ENGINEER TO SUIT NEW WORKS.
[ZLNOTEA 6 15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
= MOUNTING BRACKETS
16. DEMOLISH EXISTING TELEVISION.
I] | 17. DEMOLISH EXISTING DOWNPIPE.
tL | 18. DEMOLISH EXISTING DECKING TO EXTENT
|i 4 | SHOWN.
— 19. DEMOLISH EXISTING DECK BALUSTRADE.
64 (ExTG)) 20, DEMOLISH EXISTING BEDROOM JOINERY.
_ _(EXTG) 21, DEMOLISH EXISTING FLOOR TILES TO EXTENT
7 SHOWN.
| ADJOINING 22, DEMOLISH EXISTING CARPET FLOORING TO
| SHARED EXTENT SHOWN.
_— —— _—_ bb 23, DEMOLISH EXISTING ROOF SHEETING.
ADJOINING BOUNDARY | ROADWAY 24. DEMOLISH EXISTING EAVES GUTTERS.
DECK OUTLINE OVER _ 25, DEMOLISH EXISTING CEILING FITTINGS AND
SHARED e SS OUNDARY = © FIXTURES.
(DEDICATED LOT 26. DEMOLISH EXISTING CEILING LINING.
ROADWAY EXCLUSIVE USE AREA) . /
. NOTE:
PLANS REPRESENT GENERAL DESIGN
NOOSA COUNCIL eo) DEMOLITION INTENT ONLY. BUILDING SCOPE TO
APPROVED PLAN (ot \ DEMOLITION FLOOR PLAN - GROUND \ ALLOW FOR FULL DEMOLITION AND REBUILD.
$1983.3225.22 19 MAY 2025 | \~_F-sexe ra FULL DEMOLITION SCOPE REQUIRED TO SUIT
PROPOSED WORKS TO BE CONFIRMED ON SITE.
NOTES: AMENDMENTS PROJECT “DRAWINGCREATED - [email protected]. THS OnAninG SHOH's DESIG NTENT ONLY AL DENSON np. | EY_OATE__DESORPTON ey FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 4:100
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A |17.08.2023] ISSUE FOR BUILDING APPROVAL cB
PROJECT NO. REVISION
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © 28.01.2025) PROJECT SCOPE ADJUSTMENTS GB 22048 c RUG Es [lt NES
4, DONO SOA PS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 a Re et eee
COPYRIGHT: [ AUTHOR: 6B DRAWING PWG, No. ae
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY | ORIGINAL SHEET SIZE A 420a97mm) DEMOLITION FLOOR PLAN - GROUND A051 (07) 3298 6938
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Compiled Approved Plans - 51983.3225.23 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.