Attachment C - Bushfire attack level report
AUSTRALIAN STANDARD 3959:2018
CONSTRUCTION OF BUILDINGS IN BUSHFIRE-PRONE
AREAS
BUSHFIRE ATTACK LEVEL REPORT v1
LOT 17 ON RP903874
268 KINMOND CREEK ROAD,
COOTHARABA
FOR
THE SHED HOUSE
JANUARY 2021
The proposed dwelling is exposed to BAL FZ under AS 3959:2018
PO Box 9566 Pacific Paradise QLD 4564
ABN 60 625 108 625
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 24 pages
Page 2
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
DOCUMENT CONTROL
Document: Bushfire Attack Level Report
Client: The Shed House
Project Number: J000756
Site: Lot 17 on RP903874 – 268 Kinmond Creek Road, Cootharaba
File Ref: C:\ CLIENTS\THE SHED HOUSE\268 Kinmond Creek Rd, Cootharaba\04
REPORTING\BUSHFIRE ATTACK LEVEL REPORT v1 – 268 Kinmond Creek Rd,
Cootharaba.docx
Version Date Distribution Author/s Approved
1 14/01/2021 The Shed House N. Willis (B. Sc., Dip. Joshua Lee (B. Sc.
CLM., mAABR) – AES) – Director
Principal Ecologist;
Joshua Lee (B. Sc. AES)
– Director
DISCLAIMER
To the extent permitted by law, North Coast Environmental Services (including its employees, partners and consultants)
excludes all liability to any person for any consequences, including but not limited to all losses, damages, costs,
expenses, and any other compensation, arising directly or indirectly, from using this publication (in part or whole) and
any information or material contained in it.
© 2021 i
Page 3
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
TABLE OF CONTENTS
1.0 INTRODUCTION 1
2.0 LEGISLATIVE TRIGGER 1
2.1 NOOSA COUNCIL BUSHFIRE HAZARD OVERLAY MAP 1
3.0 THE BUILDING APPLICATION 2
4.0 SITE DESCRIPTION 2
4.1 GENERAL 2
4.2 VEGETATION TYPES AND SLOPE 3
5.0 AS 3959:2018 BAL ASSESSMENT 6
5.1 METHODOLOGY 6
5.2 RESULTS 7
5.3 VEGETATION MANAGEMENT 7
6.0 CONCLUSION 9
7.0 REFERENCES 10
APPENDIX 1 – BUILDING PLANS 11
APPENDIX 2 - FLAMESOL OUTPUTS 12
© 2021 ii
Page 4
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
1.0 INTRODUCTION
North Coast Environmental Services have been engaged to provide a Bushfire Attack Level
Report in accordance with Australian Standard 3959 (2018) Construction of buildings in bushfire-
prone areas. The Bushfire Attack Level (BAL) assessment was requested to assess the National
Construction Code construction requirements for a proposed new dwelling within Lot 17 on
RP903874, located at 268 Kinmond Creek Road, Cootharaba (herein referred as ‘the site’).
2.0 LEGISLATIVE TRIGGER
The National Construction Code 2019 (Amendment 1) dated July 2020, Performance
Requirement P2.7.5 Buildings in bushfire prone areas states:
A Class 1 building or a Class 10a building or deck associated with a Class 1 building that is
constructed in a designated bushfire prone area must, to the degree necessary, be designed and
constructed to reduce the risk of ignition from a bushfire, appropriate to the —
(a) potential for ignition caused by burning embers, radiant heat or flame generated by a bushfire;
and
(b) intensity of the bushfire attack on the building.
Under NCC 2019 Amendment 1 July 2020, Section 3.10.5.0 Application states:
(a) Subject to (b), Performance Requirement P2.7.5 is satisfied for:
• A Class 1 building; or
• A Class 10a building or deck associated with a Class 1 building
located in a designated bushfire prone area if it is constructed in accordance with –
• AS3959; or
• NASH Standard – Steel Framed Construction in Bushfire Areas.
(b) The requirements of (a) do not apply when, in accordance with AS 3959, the classified
vegetation is Group F rainforest (excluding wet sclerophyll forest types), mangrove communities
and grasslands under 300 mm high.
In accordance with the definition in the NCC, a designated bushfire prone area in Queensland
means:
• land which has been designated under a power of legislation as being subject, or likely to
be subject, to bushfires.
2.1 Noosa Council Bushfire Hazard Overlay Map
The Bushfire Hazard Overlay Map of the Noosa Plan 2020 identifies that the site is affected by a
High Bushfire Hazard Area and Potential Impact Buffer (refer to Plate 1). The proposed new
dwelling is to be located within the High Bushfire Hazard Area.
© 2021 1
Page 5
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
Plate 1 – Bushfire Hazard Overlay (Noosa Plan 2020)
3.0 THE BUILDING APPLICATION
The applicant seeks certification approval to construct a new primary dwelling within the site.
Building plans are attached as Appendix 1 to this report.
4.0 SITE DESCRIPTION
4.1 General
Lot & Plan: Lot 17 on RP903874
Street Address: 268 Kinmond Creek Road, Cootharaba
Site Area: 39,834m2
Land use: Rural Zone
Dominant site slope: 11º south aspect
QFES Forest Fire Danger Index (FFDI): 47 (Redi Map – refer Plate 2)
Plate 2 – Redi Map (QFES FFDI 2021)
© 2021 2
Page 6
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
4.2 Vegetation Types and slope
The observed relevant AS 3959:2018 vegetation types adjacent to the build site and their
underlying effective slopes for the proposed works are described in Table 1.
Table 1 – Vegetation Types and Slope surrounding the location of works
Direction North South East West
Vegetation Type A - Forest Type A - Forest Type A - Forest Type A - Forest
Type
Vegetation Canopy – Canopy – Canopy – Canopy –
Description Eucalyptus Eucalyptus Eucalyptus Eucalyptus cloeziana
cloeziana (Gympie cloeziana (Gympie cloeziana (Gympie (Gympie messmate),
messmate), messmate), messmate), Lophostemon
Lophostemon Eucalyptus grandis Lophostemon confertus
confertus (flooded gum), confertus (Brushbox),E.
(Brushbox),E. Lophostemon (Brushbox),E. microcorys
microcorys confertus microcorys (tallowwood)
(tallowwood) (Brushbox) (tallowwood) Corymbia intermedia
Corymbia Corymbia (pink bloodwood).
intermedia (pink intermedia (pink
bloodwood). bloodwood).
Mid-canopy –
Mid-canopy – Mid-canopy – Mid-canopy –
Backhousia
Backhousia Backhousia Backhousia
myrtifolia (plum
myrtifolia (plum myrtifolia (plum myrtifolia (plum
myrtle), Syzygium
myrtle), Syzygium myrtle), Syzygium myrtle), Syzygium
australe (lilly pilly).
australe (lilly pilly). australe (lilly pilly). australe (lilly pilly).
Understorey –
Understorey – Understorey – Understorey –
Lomandra hystrix
Lomandra hystrix Lomandra hystrix Lomandra hystrix
(Spiky matrush),
(Spiky matrush), (Spiky matrush), (Spiky matrush),
Cordyline rubra (Lion
Cordyline rubra Cordyline rubra Cordyline rubra
palm) Eupomatia
(Lion palm) (Lion palm) (Lion palm)
laurina (bolwarra),
Eupomatia laurina Eupomatia laurina Eupomatia laurina
Adiantum hispidulum
(bolwarra), (bolwarra), (bolwarra),
(maidenhair fern)
Adiantum Adiantum Adiantum
and Smilax australis
hispidulum hispidulum hispidulum
(barbed wire vine)
(maidenhair fern) (maidenhair fern) (maidenhair fern)
and Smilax australis and Smilax and Smilax
(barbed wire vine) australis (barbed australis (barbed
wire vine) wire vine)
QFES 2019 8.1 Wet Eucalypt 8.1 Wet Eucalypt 8.1 Wet Eucalypt 8.1 Wet Eucalypt tall
Vegetation tall open forest tall open forest tall open forest open forest
Hazard
Combined Surface Combined Surface Combined Surface Combined Surface
Class and
fuels 31 t/ha fuels 31 t/ha fuels 31 t/ha fuels 31 t/ha
fuels loads
Total Fuels 35 t/ha Total Fuels 35 t/ha Total Fuels 35 t/ha Total Fuels 35 t/ha
Underlying Upslope 1⁰ Downslope 12⁰ Downslope 10⁰ Upslope 1⁰
Effective
Slope
Plate 3 depicts the site location and the surrounding vegetated conditions.
© 2021 3
Page 7
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
Approximate location
of proposed dwelling
Plate 3 – Property Conditions (Source: NearMap)
Plates 4 and 5 depict typical conditions in the observed Type A Forest about the build site.
Plate 4 – VHC 8.1 - Type A Forest
© 2021 4
Page 8
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
Plate 5 – VHC 8.1 - Type A Forest
Plate 6 depicts topographic conditions within and adjacent to the site.
Plate 6 – Topography (Source: Noosa Council Interactive Mapping)
© 2021 5
Page 9
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
5.0 AS 3959:2018 BAL ASSESSMENT
AS 3959:2018 provides minimum construction requirements for assessable building works in
Designated Bushfire Prone Areas. Dwellings (and renovated parts of existing dwellings) in
Designated Bushfire Prone Areas must be built to the BAL construction standard relevant to the
dwelling as identified by AS 3959:2018.
5.1 Methodology
The BAL identified herein has been determined by using the normative procedure described in
Appendix B (Method 2) of AS 3959:2018. Table 2 describes the general steps used under AS
3959:2018 to determine the BAL.
Table 2 – Methodology
Step Clause Procedure
1 2.2.2 Determine the relevant fire danger index.
2 2.2.3 Determine the classified vegetation type(s)
3 2.2.4 Determine the distance of the site from the classified vegetation type(s)
4 2.2.5 Determine the effective slope(s) under the classified vegetation type(s)
5 2.2.6 Determine the BAL from the appropriate table (Flamesol model used).
6 2.2.7 Determine the appropriate construction requirements.
Quantitative modelling of the potential bushfire conditions that may be experienced within the
Type A Forest vegetation located surrounding the location of the proposed dwelling has been
undertaken to identify the BAL acting on the works. The FLAMESOL Minimum Distance calculator
has been used to ascertain the BAL dimensions and comprises an AS 3959:2018 Method 2
(Appendix B) based calculator. The following input data was used to determine the BAL based
on the conditions observed during the site inspection in January 2021 and the plans presented
for assessment (refer to Table 3).
Table 3 – Input Data
Input Parameter Input Data
Fire Danger Index 47 (QFES 2019)
Type A Forest – all directions
AS 3959 Vegetation Type
QFES Vegetation Hazard Classes and Fuel VHC 8.1 Wet Eucalypt tall open forest (combined
Loads surface fuels 31 t/ha and 35 t/ha total fuels)
North – 10m
Distance of classified vegetation from
South – 10m
building
East – 10m
Note- The Noosa Plan allows 10m exempt West – 10m
clearing for building works on Category 3
Lots
North – 1º Upslope
Effective slope(s) under the classified
South – 12º Downslope
vegetation type
East – 10º Downslope
West – 1º Upslope
Flame Width 100m - North, East & West, 45m – South (based on
post development (i.e. 10m exempt clearing about
© 2021 6
Page 10
Bushfire Attack Level Report v1 NCES REF: J000756
Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba
Input Parameter Input Data
building) north south width of Type A Forest positioned
forward of Type F Rainforest
5.2 Results
The Flamesol Minimum Distance outputs are summarized in Table 4 with the full transcripts
presented in Appendix 2.
Table 4 – BAL Minimum Distances
BAL Setback Distance Required from Edge of Assessable Vegetation (m)
Construction
Standard North 1º South 12º East 10º West 1º
BAL Flame <13.3m <21m <20m <13.3m
Zone
13.3 - <17.9m 21 – 26.1m 20 - <26.5m 13.3 - <17.9m
BAL 40
BAL 29 17.9 - <25.9m 26.1 – 33.6m 26.5 - <37.3m 17.9 - <25.9m
BAL 19 25.9 – <36.1m 33.6 – 42.2m 37.3 - <50.4m 25.9 – <36.1m
BAL 12.5 36.1 – 100m 42.2 - 100m 50.4 – 100m 36.1 – 100m
The proposed dwelling, in the absence of further vegetation clearing approval, is assumed to be
seperated by a maximum of 10m to Type A Open Forest classified vegetation in all directions.
10m exempt clearing is afforded to dwellings on Category 3 Lots (>2ha not in protected vegetation
overlay area) and Category 4 Lots (>2ha and <10ha in protected vegetation overlay area) under
the defintion of Exempt Clearing (Clause (g)) in the Noosa Plan 2020. The Lot is assumed to be
a Category 3 lot. Therefore, in accordance with Table 4 the dwelling is exposed to BAL FZ.
An application for additional vegetation clearing can be made to NSC to increase the separation
distance hence lower the resultant BAL acting on the building. The extent of proposed vegetation
clearing should be identified on the proposed building plans. Generally, NSC is amenable to
approving vegetation clearing to secure no less than BAL 29.
5.3 Vegetation Management
The vegetation between the dwelling and the adjacent edge of the hazardous vegetation must be
maintained as low threat vegetation in order for the BAL ratings to be valid and to maintain these
BAL ratings into the future.
Vegetation conditions within the setbacks attributable to each BAL must comprise low threat
vegetation as per the definition prescribed in the Standard in order for the BAL construction
standards to be effective as intended. Clause 2.2.3.2 (f) of the Standard defines Low threat
vegetation as:
© 2021 7
Page 11
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba © 2021 8
Page 12
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba 6.0 CONCLUSION The dwelling proposed to be constructed at 268 Kinmond Creek Road, Cootharaba, has been assessed as being exposed to BAL FZ. BAL FZ is primarily concerned with protection from flame contact together with ember attack and radiant heat of more than 40 kW/m2. Construction in BAL FZ may require reliance on measures other than construction. The requirements for construction of a building in BAL FZ may be regulated by the building authorities having jurisdiction in the States and Territories of Australia. A building assessed as being BAL FZ shall comply with Section 3 and Clauses 9.2 to 9.8 of AS3959:2018 and have a minimum setback of 10m from the edge of the classified vegetation. There are a number of Standards that specify requirements for construction; however, where AS3959 2018 does not provide construction requirements for a particular element, the other Standards apply. Any element of construction or system that satisfies the test criteria of AS 1530.8.2 may be used in lieu of the applicable requirements contained in Clauses 9.2 to 9.8 of AS 3959 2018. An application for additional vegetation clearing can be made to NSC to increase the separation distance hence lower the resultant BAL acting on the building. The extent of proposed vegetation clearing should be identified on the proposed building plans. Generally, NSC is amenable to approving vegetation clearing to secure no less than BAL 29. Table 4 should be used to determine necessary separation distances in each direction to achieve lower BAL ratings. In accordance with AS3959, the most severe BAL assigned to an elevation is to be assigned to the entire dwelling. All queries regarding building materials should be discussed with the architect and/or building designer and confirmed to be compliant with the requirements of the AS 3959:2018 by a registered building certifier. © 2021 9
Page 13
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba 7.0 REFERENCES Standards Australia Committee FP-020, 2018. AS 3959:2018 Construction of buildings in bushfire-prone areas. Standards Australia, Sydney NSW. Leonard, J., Newnham, G., Opie, K., and Blanchi, R. (2014). A new methodology for state-wide mapping of bushfire prone areas in Queensland. CSIRO, Australia. Leonard, J., Opie, K. (2017). Estimating the Potential Bushfire Hazard of Vegetation Patches and Corridors. CSIRO, Australia. Queensland Fire and Emergency Services. (2019). Bushfire Resilient Communities - Technical Reference Guide for the State Planning Policy - State Interest Guideline - Natural Hazards, Risk and Resilience 2- Bushfire. Southeast Queensland Fire and Biodiversity Consortium – Operational Manual. The State of Queensland, Department of State Development, Manufacturing, Infrastructure and Planning (2019). Natural hazards, risk and resilience - Bushfire State Planning Policy – state interest guidance material. © 2021 10
Page 14
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba APPENDIX 1 – BUILDING PLANS © 2021 11
Page 15
SITE PLAN
LOT PLAN : 17RP903874
ADDRESS : 268 KINMOND CREEK RD, COOTHARABA QLD 4565
AREA : 39,834m2
ZONING : RURAL ZONE
PROPOSED WORKS
CONSTRUCTION OF A PRIMARY DWELLING
GFA : 90m2
43.3 m
DRAWING LIST - BUILDING APPROVAL
Number Sheet Name Rev Date 108.9 m
101 SITE PLAN B 05.01.2021
102 FLOOR PLAN B 05.01.2021
103 ROOF PLAN B 05.01.2021 PROPOSED
104 ELEVATIONS B 05.01.2021 DWELLING
105 SECTIONS B 05.01.2021
106 SCHEDULES & LEGEND B 05.01.2021
107 BATHROOM FLOOR PLAN B 05.01.2021
108 KITCHEN FLOOR PLAN B 05.01.2021
REVISIONS:
NR: DATE: NAME:
A 27.11.2020 CONCEPT DESIGN
B 05.01.2021 DESIGN DEVELOPMENT
268 Kinmond Creek Rd, Cootharaba
101 SITE PLAN Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale 1 : 1000 @ A3 B 05.01.2021 DESIGN DEVELOPMENT of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
N Telephone : 1800 270 750
DESIGN DEVELOPMENT Email : [email protected]
Page 16
FLOOR PLANA B9465 C D E 7215 F G
90 4500 90 4695 1 90 7215
LIVING KITCHEN 105 DECK
4590 90 1903 90 1000 90 5741 94 900 90 2003 90
DECK ROBE HALLWAY ROBE
W02 OUTLINE OF ROOF OVER
1
90
90
DW FR
3605
KITCHEN / DINING
2
19 m²
105
DECK
DECK
4050
4140
3960
3960
29 m²
W01 X01
LIVING
18 m² FP
D01 X02
2
600 90
90
90
X04 ROBE
ROBE
D07
990
990
D03
D02 D08
D04 D05 D06 3
90
90
LAUNDRY
BEDROOM 3 LAUNDRY BEDROOM 1
810
11 m² 1 m² WM 11 m²
DECK
90
4135
BEDROOM
10 m²
3445
W03
2965
X03
BATHROOM
BEDROOM 2 BATHRM
9 m²
2065
6 m²
4
90
90
90
W07 W06 W05 W04
AWNING
4590 90 2993 90 2985 90 900 90 1680 90 2993 90
BEDROOM 3 BEDROOM 2 LAUNDRY BEDROOM 1
4590 90 2993 90 2985 90 2670 90 2993 90
2400 12090
268 Kinmond Creek Rd, Cootharaba
102 FLOOR PLAN Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale 1 : 50 @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
N
Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 17
ROOF PLAN A B C D E F G
1
22°
2
3
22°
4
268 Kinmond Creek Rd, Cootharaba
103 ROOF PLAN Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale 1 : 50 @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
N
Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 18
ELEVATIONS
4 3 2 1 G F E D C B A
ROOF ROOF
2700 2700
W03
X01
X02 W02
GF GF
0 0
1 SOUTH ELEVATION 2 EAST ELEVATION
104 1 : 100 104 1 : 100
1 2 3 4 A B C D E F G
ROOF ROOF
2700 TIMBER BEAM 2700
W01 W05 W04
X04 W07 W06
2700
X03
GF GF
0 0
3 NORTH ELEVATION 4 WEST ELEVATION
104 1 : 100 104 1 : 100
REFER TO ENERGY EFFICIENCY REPORT FOR MINIMUM WALL,
ROOF AND CEILING INSULATION REQUIREMENTS
268 Kinmond Creek Rd, Cootharaba
104 ELEVATIONS Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale 1 : 100 @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 19
SECTIONS
4 3 2 1 G F E D C B A
2 1
105 105
ROOF ROOF
2700 KITCHEN / DINING 2700
4257
KITCHEN / DINING LIVING
BEDROOM 2
2700
2400
GF GF
0 0
1 CROSS SECTION 2 LONGITUDINAL SECTION
105 1 : 100 105 1 : 100
268 Kinmond Creek Rd, Cootharaba
105 SECTIONS Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale 1 : 100 @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 20
SCHEDULES
DAYLIGHT & VENTILATION SCHEDULE
Room Area Total glazed area Total ventilation opening
BEDROOM 2 9 m²
BEDROOM 3 11 m²
BEDROOM 1 11 m²
LIVING 18 m²
KITCHEN / DINING 19 m²
INTERNAL DOOR SCHEDULE WINDOW SCHEDULE
Mark Height Width Door Type Mark Height Width Sill Height Window Type
D01 2100 1000 Cavity slider W01 1200 3210 900 Four-panel sliding window aluminium & glass FSSF2132
D02 2100 1800 Two-panel sliding wardrobe door W02 600 1810 900 Sliding window aluminium & glass FS0618
D03 2100 820 Honeycomb flush panel swing door W03 1200 3210 900 Four-panel sliding window aluminium & glass FSSF2132
D04 2100 820 Honeycomb flush panel swing door W04 1200 1810 900 Sliding window aluminium & glass FS1218
D05 2100 820 Honeycomb flush panel swing door W05 600 1210 900 Sliding window aluminium & glass FS0612
D06 2100 1600 Two-panel sliding wardrobe door W06 1200 1810 900 Sliding window aluminium & glass FS1218
D07 2100 820 Honeycomb flush panel swing door W07 1200 1810 900 Sliding window aluminium & glass FS1218
D08 2100 1900 Two-panel sliding wardrobe door ALL EXTERNAL DORS AND OPENING WINDOWS TO BE FITTED WITH INSECT SCREENING
EXTERNAL DOOR SCHEDULE
Mark Height Width Door Type
X01 2100 3200 Four-leaf bifold window aluminium & glass 2132
X02 2100 910 Swing door with glass panel
X03 2100 1800 Two-panel glass sliding door aluminium & glass FS2118
X04 2100 1800 Two-panel glass sliding door aluminium & glass FS2118
268 Kinmond Creek Rd, Cootharaba
106 SCHEDULES & LEGEND Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 21
KITCHEN
E F
2658
900 90 1680
3
90
900
90
LEGEND
CODE DESCRIPTION
CAB CABINET
DR DRYER SPACE
900
FFL FINISHED FLOOR LEVEL
2965
FW FLOOR WASTE
LD LINEAR DRAIN
LS LAUNDRY SINK
TRH OHC OVERHEAD CUPBOARDS
SHW SHOWER
15
TIL FLOOR TILES
WC TRH TOILET ROLL HOLDER
TWL TOWEL RAIL
BATHRM WB WASH BASIN
WC WALL-HUNG WATER-SAVING
6 m² TOILET
FW
WM WASHING MACHINE SPACE
1150
SHW
WB
4
500 1256
TWL 15 LD 900
268 Kinmond Creek Rd, Cootharaba
107 BATHROOM FLOOR PLAN Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale As indicated @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
N Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 22
LAUNDRY & BATHROOM
B C D
4695
90 600 600 600 600 600 695 1000
1
OHC FR
DW
CKT OVN KS
LEGEND
CODE DESCRIPTION
CAB CABINET
CKT COOKTOP & RANGE HOOD
DRW DRAWERS
DW DISHWASHER SPACE
FFL FINISHED FLOOR LEVEL
FR FRIDGE
KS KITCHEN SINK
MW MICROWAVE
OHC OVERHEAD CUPBOARDS
OVN UNDER-BENCH OVEN
SHL SHELF/SHELVES
SPL SPLASHBACK
ST STORAGE SPACE
TIL FLOOR TILES
268 Kinmond Creek Rd, Cootharaba
108 KITCHEN FLOOR PLAN Revision Date Description Do not scale off this drawing. All dimensions to be verified on site.
This design and drawing and the copyright thereof are the property
Scale As indicated @ A3 A 27.11.2020 CONCEPT DESIGN of The Shed House and must not be used or copied without the
written authority of The Shed House. QBCC licence 1514 0876.
N Telephone : 1800 270 750
CONCEPT DESIGN Email : [email protected]
Page 23
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba APPENDIX 2 - FLAMESOL OUTPUTS © 2021 12
Page 24
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba © 2021 13
Page 25
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba © 2021 14