EXISTING SERVICES CODE

Table 14-54 Existing Services


SPECIFIC OUTCOMES                             PROBABLE SOLUTIONS                                               ASSESSMENT

Setbacks and easements

O1 Development near a sewer, water main,      S1.1 The footing of any structure or building is located clear   S1.1 Complies
                                                                                                               All buildings and structures are located
stormwater drain, overland flow path or       of the zone of influence but no closer than 1.5m (measured
                                                                                                               further than 1.5m from any easement on
associated structure does not—                horizontally) from infrastructure including sewers, water
                                                                                                               site, existing or proposed.
    a) adversely affect the function of the   mains and stormwater structures; AND

        service;                              S1.2 No building or structure overhangs the zone of              S1.2 Complies

    b) place an additional load on the        influence; AND                                                   S1.3 –S1.5 Complies
                                                                                                               Where levels are required to be altered and
        service; and                          S1.3 Finished surface levels maintain a minimum of 600mm
                                                                                                               existing services are required to be
    c) unduly increase future maintenance     of cover, but no greater than 3m of cover to the
                                                                                                               relocated, they will be done in accordance
        costs.                                underground infrastructure; AND
                                                                                                               with PSP6 –Engineering Design Standards
                                              S1.4 If the existing surface level is altered, surface level     — Water and Sewerage and Section 4 of

                                              services including manholes and inspection points are            PSP5 –Engineering Design Standards –
                                                                                                               Roads, Drainage and Earthworks
                                              altered to match the new surface level; AND

                                              S1.5 Alterations are constructed in accordance with PSP6 –
Log in to download the original file

Appendix E - Local Code Response.pdf · 3.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.