SPECIFIC OUTCOMES PROBABLE SOLUTIONS ASSESSMENT
by— measured from the outer walls of the building ; or
i. causing ponding on the site or b) the design consists of a suspended floor
nearby land; construction; AND
S17.4 Complies
ii. increasing flooding, which S17.4 Car parking and manoeuvring areas are constructed
adversely affects the safety or at a level that permits the parking area to drain from the site
use of any land upstream and by gravity means, without the need for mechanical
S17.5- S17.6 Not Applicable
downstream; and pumping; AND
iii. adversely affecting the flow of S17.5 Basements for residential uses have flood immunity No basements proposed.
water in any overland flow above the Q100 where alternative means to mechanical
path. pumping are used to achieve such immunity; or
S17.6 Basements for non-residential uses have flood
immunity above the Q100 that may be achieved by means
of mechanical pumping where the mechanical feature is
installed with adequate holding tanks and an alternative
back up power source.
Sloping sites Not Applicable