response plans
Attached to the e-mail Response to RFI - MCU21/0145 - 170-174 Eumundi Noosa Road Noosaville.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn NOTE:
· ALL WALLS OTHER THAN REINFORCED BLOCKWORK ARE TO BE A DESIGN AND CONSTRUCT ITEM.
· WHERE AN ITEM OF THE WORKS (EG RETAINING WALL, TRUSS, SHORING, PILES, WATER QUALITY DEVICE)
IS NOMINATED AS 'DESIGN AND CONSTRUCT' OR AS A PROPRIETARY ITEM, THE PRODUCT IS TO BE
DESIGNED AS A SYSTEM AND CONSTRUCTED BY THE CONTRACTOR AS PART OF ITS CONTRACT ACTIVITIES,
WITH CERTIFICATION (DESIGN & CONSTRUCTION) BY A REGISTERED PROFESSIONAL ENGINEER OF
QUEENSLAND. THE DESIGNER IS TO MAKE ALLOWANCE FOR ALL LOADS, FIXINGS AND PENETRATIONS
THAT ARE SHOWN ON THE PROJECT DRAWINGS OR THAT CAN BE REASONABLY ANTICIPATED.
· ALTERNATIVES TO ANY NOMINATED SYSTEM WILL BE CONSIDERED BUT MUST BE AGREED IN WRITING BY
THE SUPERINTENDENT AS BEING EQUIVALENT IN BOTH PERFORMANCE AND AESTHETICS.
· ALL INFORMATION RELATING TO THE SYSTEM AND THE INVESTIGATION UNDERTAKEN MUST BE
SUBMITTED TO SUPERINTENDENT PRIOR TO THE COMMENCEMENT OF THE CONSTRUCTION, INCLUDING
DESIGN CERTIFICATION. THE INVESTIGATION AND DESIGN OF THE SYSTEM SHALL BE COMPLETED TO
INCLUDE BUT NOT LIMITED TO AS4678, TEMPORARY SHORING OR SUPPORTS, FOOTINGS, BACKFILL,
PENETRATIONS, AND ANY FIXINGS SUCH AS FENCES AND HANDRAILS.
· WHERE AVAILABLE GEOTECHNICAL INFORMATION IS DEFICIENT, THE DESIGNER SHALL COMPLETE THEIR
OWN GEOTECHNICAL INVESTIGATION OF THE GROUND CONDITIONS OF THE SITE INCLUDING WATER
TABLE LEVEL AND SURCHARGE / LIVE LOADS APPLICABLE.
NOTE
· CUT: -96.5M3
· FILL: 679M3
· BALANCE: 582.5M3 (IMPORT)
· RETAINING WALL: UP TO 2M
20.00
UP
FFL 20.300m
E
20.00
E
E
E
E
WM
WM
E
E
E
EE
EE
0
20.0 EE
EE
EE
EE
EE
EE
EE
H
EE
E
EE
E
E EE
E
EE
E
E EE
WM
EE
THIS DRAWING IS BEST
EE VIEWED IN COLOUR AND
EE
ON AN ELECTRONIC DEVICE
EE
PROJECT NORTH
EE
EE
EE
EE
J:\2021\21308\05_DRAWINGS\DRG\SK-C1000.DWG
DIMENSIONS IN METRES EXCEPT WHERE A1 UNREDUCED
SHOWN OTHERWISE. CULVERT AND PIPE
SIZES IN MILLIMETRES A3 REDUCED
SCALES UNREDUCED / REDUCED
0 2.0 4.0 6.0 8.0 10.0 m
1 : 200 / 1 : 400
PLAN STATUS
SCALE 1:200
PRELIMINARY
DWN DES CHK APP CLIENT PROJECT SUBJECT PROJECT No.
SCAN QR CODE TO
REV DATE DESCRIPTION
ASSOCIATED CONSULTANTS APPROVED CHECKED
I2C ARCHITECTS PTY LTD NOOSAVILLE TYRE 21308
1/10/2021 3:15:51 PM
CONFIRM CURRENT
A 01.10.21 RFI RESPONSE ABU KN
EARTHWORKS LAYOUT
DRAWING REVISION
7729 AND AUTO PLAN DRAWING No. REVISION
RPEQ
http://docs.bornhorstward.com.au/revision/
DATE DATE
RETAIL DEVELOPMENT SK-C1000 A
COPYRIGHT © - This document is and shall remain the property of Bornhorst & Ward Pty. Ltd. The document may only be used for the purpose for which it was commissioned and in accordance with the terms of engagement. Unauthorised use of this document in any form whatsoever is prohibited.
0 10 20 30 40 50 100 ORIGINAL SIZE A1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.