planning report Other Change

of 89

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                        concave to allow concentration of
                                        water to the centre of the ramp.
PO15                                    No acceptable outcome provided.           N/A
No new boat ramps are constructed
within the Noosa River system.
PO16                                    AO16.1                                    N/A
Works are designed and sited to         For lots with watercourse frontage
ensure—                                 greater than 15 metres in width,
                                        jetties are setback a minimum of 3
(a) they are contained within the       metres from the prolongation of the
    prolongation of boundaries of the   boundaries (Refer Figure 9.4.9.3A).
    lot;
(b) that when a vessel is berthed it    AO16.2
    does not encroach over the          For lots with watercourse frontage
    prolongation of boundaries of the   less than 15 metres in width
    lot;                                (including lots located in watercourse
                                        bends or at the head of the
(c) a high level of visual amenity is   watercourse)—
    maintained when viewed from
    the watercourse and adjoining
    lands;                              (a) a joint application is made with
                                            the adjoining owner; or
(d) the works avoid conflicts with      (b) where a joint application is not
    uses in the water, on the               possible, jetties—
    foreshore and adjoining lands;
(e) materials blend with the natural                (i)    are setback a
    surrounds;
                                                           minimum of 1
(f) cluttering of watercourses is                          metres from the
    avoided;                                               prolongation of the
(g) excessive traffic volumes within                       boundaries;
    foreshore areas, on adjoining                  (ii)    are not more than
    lands and in the water are                             1.5 metres in
    avoided; and                                           width;
(h) they reflect the character and                 (iii)   have no jetty head;
    setting of the work’s immediate                (iv)    allow for safe
    surrounds of the locality.
                                                           access and
                                                           manoeuvrability of
                                                           vessels for both
                                                           the neighbouring
                                                           property and the
                                                           subject property;
                                                           and
                                                   (v)     are not constructed
                                                           on sites where
                                                           there is an existing
                                                           shared jetty on
                                                           either prolongation
                                                           of the side property
                                                           boundaries.

                                        AO16.3
                                        For lots that adjoin those described in
                                        AO16.2, the jetty is located well away
                                        from the common boundary.
PO17                                    No acceptable outcome provided            N/A
Landings are not roofed.
PO18                                    No acceptable outcome provided.           N/A
Structures such as handrails, light
bollards, piers and pumping
equipment for semi-submersible
floating docks have a maximum
height of 1100mm above the jetty
floor.
PO19                                    AO19.1                                    N/A
Development is designed and             Jetties—
constructed for the sole purpose of
providing access to vessels and are     (a) are a maximum width of 1.5
sited and designed to avoid—                metres;

(a) cluttering of waterways;
                                                                                        Page 81 of 89
Log in to download the original file

planning report Other Change.pdf · 1.8 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.