Table A: ACCEPTABLE FORMS OF CONSTRUCTION
Description R w + C tr (not less than) Construction
Description R w + C tr (not less than) Construction
Wall construction type: Autoclaved aerated concrete
Wall construction type: Masonry
75 mm thick autoclaved aerated concrete wall panel with:
Two leaves of 110 mm clay brick masonry with: (a) a row of 64 mm steel studs at 600 mm centres, spaced 20 mm 50
(a) cavity not less than 50 mm between leaves; and from the autoclaved aerated concrete wall panel; and
50
(b) 50 mm thick glass wool insulation with a density of 11 kg/m3 (b) 75 mm thick glass wool insulation with a density of 11 kg/m3
or 50 mm thick polyester insulation with a density of 20 kg/m3 positioned between studs; and
in the cavity. (c) one layer of 10 mm moisture resistant plasterboard or 13 mm fire
protective grade plasterboard fixed to outside face of studs and
Two leaves of 110 mm clay brick masonry with— outside face of autoclaved aerated concrete wall panel.
(a) cavity not less than 50 mm between leaves; and
50 75 mm thick autoclaved aerated concrete wall panel with—
(b) 13 mm cement render on each outside face.
(a) a row of 64 mm steel studs at 600 mm centres, spaced 35 mm 50
from the autoclaved aerated concrete panel wall; and
(b) 28 mm metal furring channels fixed to the outside face of the
Single leaf of 110 mm clay brick masonry with— autoclaved aerated concrete wall panel, with
(a) a row of 70 mm x 35 mm timber studs or 64 mm steel studs at 50 mm thick polyester insulation with a density of
600 mm centres, spaced 20 mm from the masonry wall; and 50 9 kg/m3 positioned between furring channels and one layer of 13
(b) 50 mm thick mineral insulation or glass wool insulation with a mm fire protective grade plasterboard fixed to furring channels;
density of 11 kg/m3 positioned between studs; and and
(c) one layer of 13 mm plasterboard fixed to outside face of studs (a) 105 mm thick glass wool insulation with a density of 7 kg/m3
and outside face of masonry. positioned between studs; and
Single leaf of 90 mm clay brick masonry with— (b) one layer of 13 mm fire protective grade plasterboard fixed to the
(a) a row of 70 mm x 35 mm timber studs or 64 mm steels studs at outside face of the studs.
600 mm centres, spaced 20 mm from each face of the masonry 50
Two leaves of 75 mm autoclaved aerated concrete wall panel
wall; and with— 50
(b) 50 mm thick mineral insulation or glass wool insulation with a (a) a cavity not less than 30 mm between panels containing 50 mm
density of 11 kg/m3 positioned between studs in each row; and glass wool insulation with a density of 11 kg/m3; and
(c) one layer of 13 mm plasterboard fixed to studs on each (b) one layer of 10 mm plasterboard fixed to outside face of each
outside face. panel.
Single leaf of 220 mm brick masonry with 13 mm cement render on
each face.
50
Wall construction type: Timber and steel framing
Wall construction type: Concrete Two rows of 90 x 35 mm timber studs or two rows of 64 mm
150 mm thick plain off form concrete. steels studs at 600 mm centres with— 50
(a) an air gap not less than 20 mm between the rows of studs; and
50
200 mm thick concrete panel with one layer of 13 mm (b) 50 mm thick glass wool insulation or 60 mm thick polyester
plasterboard or 13 mm cement render on each face. insulation with a density of 11 kg/m3; positioned between
50 one row of studs, and
(c) two layers of 13 mm fire protective grade plasterboard or one layer
100 mm thick concrete panel with— of 6 mm fibre cement sheet and one layer of 13 mm fire protective
(c) a row of 64 mm steel studs at 600 mm centres, spaced grade plasterboard, fixed to outside face of studs.
25 mm from the concrete panel; and 50
(d) 80 mm thick polyester insulation or 50 mm thick glass wool
insulation with a density of 11 kg/m3, positioned between studs;
and
(e) two layers of 13 mm plasterboard fixed to outside face of studs
Two rows of 64 mm steel studs at 600 mm centres with—
and one layer of 13 mm plasterboard fixed to outside face of
(a) an air gap not less than 80 mm between the rows of studs; and 50
concrete panel.
(b) 200 mm thick polyester insulation with a density of 14 kg
125 mm thick concrete panel with: kg/m3; positioned between studs; and
(c) a row of 64 mm steel studs at 600 mm centres, spaced 50 (c) one layer of 13 mm fire-protective grade plasterboard and one
20 mm from the concrete panel; and layer 13 mm plasterboard on one outside face and one layer of 13
(d) 70 mm polyester insulation with a density of 9 kg/m3, positioned mm fire-protective grade plasterboard on the other outside face.
between studs; and
(e) one layer of 13 mm plasterboard fixed to the outside face of the
studs.
© Farside Trading Pty Ltd 2015, not to be reproduced with permission.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20150300 - Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.