Original source · versioned page text
Appendix J - Civil Engineering Report and SBSMP.pdf
EX
EX KE
KE RB
RB
M
EX
W
FO
16
O
TP
PN
AT
H
0
10
PE
5
KS
12
OR
EX
D
EW
O
TE
EX LS
EW
IN
FL
D TR
OF
N
N A
15
0
oP
R
VC OD125 EF COUPLING
TE
WA
PN
ITY
16
UN
W
M
BY
OD125 STUB FLANGE (SS316)
KS
WITH EF COUPLING
OR
EW
LIV
DN100 THRUST RESTRAINT
600mm LONG (FL-FL)
DN150 OFFTAKE (FL) DN100 VALVE (FL-FL)
LIV
EW
OR
KS
CONNECTION DETAIL C BY
UN CONTRACTOR
REFER TO DRAWING 1856-W04 ITY
WA
SCALE 1:40 (A3) TE
R ALL THRUST BLOCKS TO
0 0.4 0.8 1.2 1.6 2.0m BE IN ACCORDANCE
WITH SEQ-WAT-1205-1 &
SEQ-WAT-1206-1
SCALE 1:40 A3
EX
EX
EX
EX
FO
TE
OP
R
DN
TO
LS
AC
OT
TIC
R
15
NT M
TR
PA
CO W
0
AL
Y 16
A
0
SB
TH
10
oP
K PN BLANK FLANGE WITH
FIB
OR 0 DN WM
VC
EW 10 W 35 BSP TAP
PE RY
RE
N NE PN
FLI DA
PN
OF 25
1 DI UN
OD
EX
16
W BO
NE
W
KE
BO
M
RB
UND
ER DN100 90° BEND
AT
AR
W
ITY (SOC-SOC)
UN
Y
BY
KS
OR
EW DN100 CONNECTOR (FL-SOC)
LIV
OD125 EF COUPLING
DN100 VALVE (FL-FL)
KS
OR
N EW DN100 TEE (FL-FL-FL)
FLI
BO
OD125 STUB FLANGE (SS316) OF
EX
UN
WITH EF COUPLING M DN100 VALVE (FL-FL)
FO
W
DA
1 6
OT
PN
RY
CONTRACTOR 0 DN100 CONNECTOR CONTRACTOR
PA
10 (FL-SOC)
PE
TH
5 BLANK FLANGE WITH
DN100 THRUST RESTRAINT ALL THRUST BLOCKS TO 12 BSP TAP ALL THRUST BLOCKS TO
OD
LIV
DN150 OFFTAKE (FL) 600mm LONG (FL-FL) BE IN ACCORDANCE W BE IN ACCORDANCE
EW
NE 0
WITH SEQ-WAT-1205-1 & 10 WITH SEQ-WAT-1205-1 &
DN WM
OR
SEQ-WAT-1206-1 SEQ-WAT-1206-1
W 5
KS
DN100 VALVE (FL-FL) OD125 STUB FLANGE NE PN3
BY
(SS316) WITH EF COUPLING DI
EX
UN
CONNECTION DETAIL B
ITY
CONNECTION DETAIL A
KE
EX
WA
REFER TO DRAWING 1856-W04
RB
REFER TO DRAWING 1856-W04
U-
DN100 90° BEND
TE
DN100 THRUST RESTRAINT SCALE 1:40 (A3)
EL
R
SCALE 1:20 (A3) (SOC-SOC)
600mm LONG (FL-FL)
EC
0 0.2 0.4 0.6 0.8 1.0m 0 0.4 0.8 1.2 1.6 2.0m
TRI
CA
SCALE 1:20 A3 SCALE 1:40 A3
L
PROJECT: JOB NUMBER
REV DATE DESCRIPTION BY CHKD DRAWN
I GDETAL
IS SCALE APPROVED PROPOSED SUBDIVISION 1856
A 18-03-20 FOR APPROVAL MM CL AT NOOSA CIVIC, WALTER HAY DRIVE
B 27-11-20 REVISED AS PER COUNCIL RFI MEETING MM CL DATUM AHD SHEET: 12 OF 17
FOR STOCKWELL PTY LTD
C 08-02-21 FOR CONSTRUCTION JP TS DESIGN MM
AS SHOWN
................. DRAWING NUMBER REV
DRAWING TITLE:
DRAWN MM Director: CAMERON LANDRETH
DESIGN CHECK (RPEQ 19358) p 07 5443 8285 WATERMAIN CONNECTION DETAIL PLAN W12 C
CL
e [email protected] w www.barlowshelley.com.au
DATE 18-03-20
This drawing is not to be copied or amended without written permission from
Barlow Shelley Consulting Engineers FOR CONSTRUCTION a PO Box 899, Maroochydore,4558 ABN 89 215 591 077 SHEET 1 OF 5
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Appendix J - Civil Engineering Report and SBSMP.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.