Original source · versioned page text
Orange on Sunrise - Appendic B - Use Plans - 151116
Attached to the e-mail Development Application - Part 1 of 2 MCU16/0144.
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn REAL PROPERTY DESCRIPTION
Storm Water
Lot: 63 On: RP200339 Surface water drainage must be prevented from
Lot / Site Area (m²): 10080 m² entering the building with fgl sloping 50mm over
Local Government: Noosa Shire Council the first 1m away from the building & the finished
slab height at a minimum FFL 150mm above FGL or
STATUTORY INFORMATION:
minimum 100mm above FGL in sandy, well drained
Building Classification: 1a areas of low rainfall intensity (Q20 125mm), or 50mm
Storeys: 1 above impermeable paved or concreted areas all
Climate Zone: 5 in accordance with BCA Vol 2 P3.1.2.3
Wind Category: N3
Carpark to Gemeral Store Domestic driveway design requirements :
General • 3m minimum width (AS 2890:2004 Amdt1, S2.6.1)
Do not scale from these drawings, figured
Dr • Maximum 1 in 4 (25%) gradient (AS 2890:2004
at e
dimensions take precedence at all times - Amdt1, S2.6.2)
sg
when in doubt consult the designer prior to
Changes in grade for straight driveways to prevent
commencing construction. It is the
g
Kin
builders responsibility to: vehicle scraping driveway require grade transitions
Existing General Store of 2m in length when:
• Verify all dimensions and levels on site. • Summit changes in grade is over 1 in 8 (12.5%)
• Ensure all boundary setbacks are strictly • Sag changes in grade is over 1 in 6.7 (15%)
adhered to. (AS 2890:2004 Amdt1, S2.5.3(d)
• Verify location and levels of all services on site.
• Verify that floors and finished levels enable Builder is to follow the best practice
Existing Crossover and
Su
connection to required services on site. guidelines for controlling stormwater
Gravel Driveway
• Real property information to be confirmed by pollution from building sites by local council
licensed surveyor prior to construction. Residence
nri
• Bearings have been corrected by modelling The builder is responsible to check all existing
software to read in a clockwise direction. services prior to beginning construction
This may cause discrepancies of 180 deg from
se
original survey information.
• Site levels, driveway design & site works to
detail by others.
Rd
These drawings have been prepared for building Drawing Schedule
permit application only. It is the builder's / proprietor's
responsibility to further interpret the design and Current Revision
drawings to detail the project for construction. Existing Structure Sheet No. Sheet Name Revision Date
Termites A.01 SITE PLAN A 15/11/16
Protection against subterranean termites to be
A.02 FLOOR PLAN A 15/11/16
in accordance with A.S. 3660 Part 1. (protection
of buildings from subterranean termites). A.03 ELEVATIONS A 15/11/16
Protection against subterranean termites to
apply to all "primary building elements".
The builder is to provide physical barriers to
the entry by subterranean termites by
construction of all slabs & timber floor framing in
accordance with A.S. 2870.1 (Residential footing
and slab construction). and A.S. 3600 (Concrete
structures code). In addition all slab penetrations
are to be protected using stainless steel mesh.
(Termimesh or equivalent fitted to manuf. spec.).
External perimeter barrier to be installed by
excavation trenches, treating the exposed
trench and backfilling the trench with treated
material and protecting the trench with a
50mm thick concrete cover strip x 300mm
wide measured from the external wall of the
building. 2 durable notices shall be installed
in prominent locations stating method of
protection, date of installation, life expectancy
and scope and duration of future inspections.
Regular inspections of the building are to be
carried out to ensure the barrier has not
been bridged by termites.
Inspections are to be carried out as per notices.
SITE PLAN
Scale 1 : 1000
AS CONTRUCTED GENERAL STORE SCALE @A3
0 1m 2m 4m 6m 8m 10m
ZEST BUIDLING DESIGN STUDIO Project Address Drawing Title 1:200
Sunshine Coast 1 Kingsgate Drive Orange on
P | 0457314346
A | 30 Wattlebird Drive, Doonan, QLD 4562
E | [email protected]
W | www.zestbuildingdesign.com.au
ABN: 37 601 151 508
Q.B.C.C Lic. No: 1307012
Sunrise TINBEERWAH 4563
Client Name
SITE PLAN
A.01
Phase Bld # Issue
Designer (s)
I. Brundell
Margaret McFarland C/O RG
Strategic
A
Issue
AsCon V2
Description
15/11/16
Date
16072 AC 00 A
Original sheet size A3 (297x420) Plot date: 15-Nov-16 4:23:59 PM
AS CON
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.