Original PDF page 1, section 1. The text section number identifies this passage in the reader.
RAN MINOR ADJUSTMENTS TO MCU 17/0559 03 LOT 87 RP 92518 16G
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of sections 2 to 4 (of 12)
Section 2
MINOR ADJUSTMENTS TO MCU 17 / 0559 03
1. FIRST FLOOR PLAN UPDATED:
A. SERVICE ROOM ADDED TO GARAGE IN ORDER TO HOUSE HEATING
RECOVERY VENTILATION (HRV) SYSTEM WITHIN THE THERMAL
ENVERLOPE. LOCATION SELECTED AS ALLOWS A DIRECT PATH TO ROOF
SPACE; ALLOWING THE DISTRIBUTION OF VENTILATION DUCTING
THROUGHOUT CEILING. (HRV REQUIRED FOR PASSIV HAUS CERTIFICATION).
2. UPPER FLOOR PLAN UPDATED:
A. INTERNAL REARRANGEMENT TO ACOOMODATE HEATING RECOVERY
VENTILATION (HRV) SYSTEM DUCTING. (HRV REQUIRED FOR PASSIV HAUS
CERTIFICATION). SPACES ARRANGED INCLUDE THE FOLLOWING:
UNIT 16: M.P.R, L'DRY, BATHROOM, KITCHEN & DINING.
UNIT 16a: BED 1, M.P.R, L'DRY, & BATHROOM.
3. RUMPAS BAR CABINETRY UPDATED.
4. EXTERNAL ACCESS/STAIRS ADDED TO POOL AREA (UNIT 16A)
5. EXTERNAL LEVELS AMENDED TO MEET EXISTING GROUND CONDITIONS &
LEVELS AS REQUESTED BY ENGINEER.
6. OPEN ROOF VERGOLA ADDED TO POOL AREA (UNIT 16 AND UNIT 16A).
AMENDMENT TO DA
MINOR ADJUSTMENT TO MCU 17/0559 03
16 GRANT STREET, NOOSA
Contact information: The information in these drawings pertaining to © COPYRIGHT Project Status: Job No: Drawing No.
PO Box 316 Bulimba Q 4171
Ph: 1300 293 029
dimensions, heights & details are for information only
and not be relied upon. Specific dimensions, heights &
All plans are copyright and FOR APPROVAL H4 N016GRAN DA 00A
remain the property of H4
E: [email protected] details are subject to change during construction. Living Pty Ltd and may not be Drawing title:
W: www.h4living.com.au Changes can occour due to multiple factors including Date: Revision:
but not limited to; service clearances, joint &
reproduced, copied, used or
altered without the written
AMENDMENTS
ABN: 36 159 311 921
QBCC: 150 14 144
construction detailing & material changes permission of H4 Living J + M GUERREIRO 05/10/23 22
Section 3
SITE NOTES:
1. GENERAL
N
W
WIN
Do not scale off plan, figured dimensions take TE
RS
SE
preference. UN
T
PA
Builder to verify all dimensions and levels on plan prior Dri
ve
TH
to commencement of construction, and no responsibility RL way
21 Lev
|72 el
is taken after commencement. Dri
ve
All services and manholes must be located and RL way
22 Lev
|40 el SET RISE
identified prior to construction.
Contours and levels shown on the plan are indicative
Dri
only and are suppied by contour surveyor. No ve
RL way Dri
responsibility is taken for accuracy of levels. 20 Lev ve
RL way CO
Telstra U/G - Shown from Records
|85 el
Water U/G - Shown from Records
E
22 Lev
2. SITE SETOUT
|70 el
MM
ON SU
RIS
Location of boundaries to be confirmed by MM
PR ER
E
Dri BU SU
surveyor/builder prior to setout. It is recommended that a O NP
S
ve P1
licenced surveyor be engaged to setout the building. RL way
22 Lev
1 03 PE AT
H
All boundary clearances shown to be verified by builder
|59 el 9
RT
prior to commencement of construction. Any variation to
Y
setout dimensions must remain with Council
requirements. 6570 SETBACK 21210 7002 SETBACK
Ad
Gr joinin
3. EARTHWORKS ou g
RL nd Le Lot
Cut and fill indicated on plan may vary at construction 22 v
|89 el
Concrete path
stage and builder shall verify and adjust as required.
All earthworks shall comply with Building Code of BU
CP
61°48'10" 34.782m
10 10 10
06 05 04 11
P8
20 20 20 05
.3 .3
.5 KL 90 25
Australia (BCA) Part 3.1 and relevant Council legislation.
KI03 69 01 KI02 64 10
03 .7
20 PA 31
76
.4 G01
KI01 87 11
31
PROPERTY BOUNDARY
10 0.00
0
10 50
44 20 TR 0
20 .7 0.40
.6 EP 78 05
EP 90 01
8U
01 10
61°48'10"
54 NKN
20 OW
.9
SETBACK
BB 80 N
10 10 01
45
20 20 46 11 11 11
.691.710 42 43 11 70 12 12
4. SEWERAGE AND STORMWATER
EP EP 1647 23 23 11 60 12 20 19
01 012010 10 .4 .7 58 24 24 21 25 26
.F .748 49 FE 14 FE 37 23 .4 .8 25 .7 .2 12
10
51 EP20 20 03 .7 FE 91 FE 61 .1 FE 18 FE 56 18
20 03 FE 81 FE 99
34|782
10 10 20 01.7 .7 11 03 03 04 04 27
07 20 08 EP .L10 CO 03 45 04 .0
.6 EP 70 FE 44
2050
0.00
20 .3 PP 70 01 01 R PA 04
.3 TR 0
Garden
KL 72 KI02 38 01 LIN 11
SL
PA 0.40 68 11
27.0
G 11
26.0
01 KI01 G01 41 11 24 69
All sewerage and stormwater drainage shall comply with
PA 0.00 04 67 .3
23 TR 86 24 1166
18 .817
G02 TR 0 .8 W TR23.8
20
EU
SL
BR 32 01
26.5
11 0.50 CAL W0199
BR
S
36 W01 TIM
0.00 03 YP W01TI
.54
T BE M
Sewer U/G - Shown from Records
TR 0 6 PO 11 R BE
S S
20
0.20 46 1111R
INC 11 0.00
11 11 7565
03 IAN 72 73 74 2323.7
BCA Part 3.1.2, AS 3500 and relevant Council legislation.
AW 0
.7
23
20.5
10 A 23 23 .6 .7
.5 .631 BR 2627
10 JA CO 01 CO 88 CO
S
CO 97
1
55 CAR .U 02W01
21 02 02 PA 02
.0 AN TIO
BB 17 DA
01
25
90
02
23.5
23
22.5
Stormwater to be discharged to Council approved
.6
.5 L2
ST 24
25
21.5
N 11
23.0
22.0
TE 76
MP 23
7.0
.7
.0
21.0
10 10 CO 37
13 20 Section 4
12 02
20
1
.3 .305
KL 50 KI02
discharge point.
90
10 01 03
14 25
24.
.8
GRANT STREET
20 ST 06
.5
KI03 81 N
Sewer U/G - Shown from Records
11 11
0
Gully Trap
77 64 TE
/G -
23 23 MP
.7 .7
Sewer U ecords
CO 43 BR 54
All roof stormwater drainage, including
02 W01
mR
Shown fro OPEN ROOF VERGOLA
11 11
S S GT 4
87
23 23 88
downpipes/drainage pipes shall be in accordance with
10 .7
56 BR BR32.737
20 W02W
.9 02 12
BB 92 TI TIM
MBE 17
EXISITNG HOUSE & POOL TO BE DEMOLISHED
01 26
RBE R
.9
FE 36
SHOWN
P1 SHADED.
331°48'10"
04
BCA Part3.5.2.
90 11
89
L2
20 00 23
ST .477 .7
17|099
03
BR 33
331°48'10" 17.099m
NN
0.5
IK W02
TIM
16
20.5
BE
6
R
TB 4
11
71 11 11
23 59 86
.6 23 0.00
CO 40
M
.6 TR 0
02 CO 56 0.60
02
5. DRIVEWAY RL N
05
20
23 ail in
10 10 EU
19 10 17 CAL
18 20
PROPOSED NEW RESIDENCE
20 11 12
TELSTRA PIT
.5 20 .3
17.099m
57 32 YP
KI03 92 .3 KI02 31 25 12 T
KL 68 23 .8 31
|87
01 .6 12 ST 34
CO 52
K
12 33 25
02 .8
Driveway to comply with Council legislation. Max. 1:5
02 34 25 .F ST 36
(AH erb
25 .8 PO 02
10
61 12 .8 ST 33 OL
20 35 ST 36 02 PO
.9 25 02 PO OL
10 10 BB 71 .8 .F OL 12
65 66 01 ST 42 PO 30
PROPOSED POOL
20 20 02 OL
D)
.6 .6 25
CO 14 PO .8
CO 16 OL ST 36
gradient to comply with Queensland Development Code.
01 01 02
TE .R .F
LS TE PO
TR LS 12 OL
A TR 36
A 25
.8
ST 36
151°48'10"
02
13000
Driveway application must be approved by Council prior
PO
11 OL
90 12
23
17|099
.7 37
10 BR 39 25
62 .8
20 W02 ST 38 12
12
16
.8 02 29 26
10 BB 56 TIM PO12 25 .8
492
64 01 BE FE 74
to construction.
O38 .8
20
.6 R 25 L ST 47 04
SW
CO 31 .8 02
01 ST 37 PO
02 OL
TE .L
LS PO
TR OL
A 12
LOT 87 - 595m²