Council archive · source document
OPW18-0163 Approved Plans · OPW18/0163
Plans and drawings: the text below has words only, no drawings.
BOUNDARY
Membership No. 563
NOTES: QBCC Lic. No. 1272165
1. REFER TO VIVA STANDARD DOCUMENT
"RVIE SITE STANDARD CHEAT SHEET (V6)" building designers'
DO NOT SCALE
FOR MANIFEST BOX SIGNAGE DETAILS association of
queensland inc. Copyright © 2016
CKD
JB
PROPOSED SERVICE
STATION SHOP
SERVICE BUILDING TENANT 1
YARD
Night Owl wall sign -
APPROVED PLANS
OPW18/0163
AMENDMENT
DELIVERIES
NOOSA COUNCIL
3 SEPTEMBER 2018
LOADING
AREA
BOUNDARY
BOUNDARY
-
PRELIMINARY ISSUE
CANOPY LINK
PROPOSED CANOPY "SHELL
WHITE" FASCIA PANEL 02 PROPOSED CANOPY "SHELL WHITE"
APPLIED NON-ILLUMINATED A801
FASCIA PANEL WITH
YELLOW/RED VINYL
16/12/16
NON-ILLUMINATED "SHELL YELLOW"
DATE
CURVED FASCIA STRIP AND
ILLUMINATED "SHELL RED" BAR
FILL BOX
ISS
NO
A
STOPPING
S6 S6 S6 S6
04
S3 S3 S3 S3 S3 S3 S3 S3 03
A801 S2 S2 S2 S2 A801
S5 S5 S5 S5
PROPOSED CANOPY S7
PRELIMINARY
PROPOSED CANOPY "SHELL WHITE" PROPOSED FUEL CANOPY
SHOP
FASCIA PANEL WITH ACCESS "SHELL" PECTEN FASCIA
NON-ILLUMINATED "SHELL YELLOW" SIGN (ILLUMINATED)
ISSUED FOR
CURVED FASCIA STRIP AND
ILLUMINATED "SHELL RED" BAR
PROPOSED 7M.
PYLON SIGN
AIR &
VENTS WATER
S1 S4
31
0L
(2m
17
)
BOUNDARY
0
SITE ENTRY SITE EXIT
L(
3m
97
L(
)
4m
) 60
L(
5m
)
1-
2L
(8m
Pylon approval
)
sought is as per MANIFEST BOX
DWG Coles Express
01
REFER NOTE 1 A801 Shell Licensee
Noosaville QLD 5m
01 SITE SIGNAGE PLAN EUMUNDI ROAD
-- 1:200 @ A1 by EVOCOM 0m 2 4 6 8 10
1:200 @A1 1:400 @A3
Studio 24/115 Wickham Street,
PO Box 724,
2010 Fortitude Valley, QLD 4006
T: 1800 616 760
E: [email protected]
W: www.cadway.com.au
1200 acn: 111 372 064 abn: 43 111 372 064
project description
VIVA NOOSAVILLE
PROPOSED SERVICE
STATION DEVELOPMENT
1200
project address
FROM SHOP
APPROACH ELEVATION
140-142 EUMUNDI ROAD
Unleaded S2 1600
signs are 250 100
NOOSAVILLE, QLD 4566
250
not approved client
Unleaded
95 VIVA ENERGY PTY LTD
7000
Premium S2
max 98
1000
5m drawing title
300
300
Diesel S3 1 2 2 1 SITE SIGNAGE PLAN
(VARIES)
S3 S3 S3 S3
4700
S2 AND SITE SIGNAGE
DETAILS
2700 MINIMUM
640 640
(VARIES)
Air AS NOTED scale
LED NUMBERS RED Quality Fuels
09/12/16 date
1400
1025
LEDs ON BLACK Premium 98
Unleaded 95
JB drawn
BACKGROUND Water Unleaded
Diesel
No
Entry
300
CK checked
11147 job no.
S1 S2 S3 S4 S5 S6 S7
SHELL INTERNALLY NON-ILLUMINATED NON-ILLUMINATED NON-ILLUMINATED NON-ILLUMINATED NON-ILLUMINATED "SHELL" LOGO LED
02 SIGNAGE DETAILS ILLUMINATED SPREADER PUMP NUMBERS "AIRTEC" UNIT LEADER BOARD "NO ENTRY" ILLUMINATED 0m 0.5 1 1.5 2 2.5
11147-A800 dwg no.
-- 1:50 @ A1 SITE IDENTIFICATION SIGN PECTEN FASCIA SIGNAGE 1:50 @A1 1:100 @A3 A issue
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
NOTES: Membership No. 563
QBCC Lic. No. 1272165
1. FIRE EXTINGUISHER STATUTORY SIGNAGE TO BE INSTALLED ON 3
SIDES OF THE CANOPY COLUMN, FACING EACH BAY AND FACING THE
PROPOSED CANOPY "SHELL WHITE" FASCIA PANEL PROPOSED 7M CANOPY HEIGHT CANOPY PECTEN building designers'
SHOP. REFER TO VIVA STANDARD DOCUMENT "RVIE SITE STANDARD DO NOT SCALE
WITH NON-ILLUMINATED "SHELL YELLOW" CURVED PYLON SIGN CLEARANCE SIGN SIGNAGE (ILLUMINATED) association of
"MAXIMUM HEIGHT 4.6M" CHEAT SHEET (V6)" FOR DETAILS queensland inc. Copyright © 2016
FASCIA STRIP AND ILLUMINATED "SHELL RED" BAR
32000 2. HSSE POSTER AND POSTER FRAME TO BE INSTALLED ON BOTH
CKD
SIDES OF THE CANOPY COLUMN; FACING EACH BAY. REFER TO VIVA
JB
4000 9000 7500 7500 4000
STANDARD DOCUMENT "RVIE SITE STANDARD CHEAT SHEET (V6)"
FOR DETAILS
S1
PROPOSED RETAIL FUEL CANOPY 4000 S7
850
Maximum height 4.6m Maximum height 4.6m
FFL TO CANOPY U/S
S2 S2 600 S2 S2
4700
8 7 S3 6 5 S3 S3 4 3 S3 S3 2 1
S3
S3 S3
AMENDMENT
-
Quality Fuels Quality Fuels Quality Fuels Quality Fuels
APPROVED PLANS
OPW18/0163
Premium 98 Premium 98 Premium 98 Premium 98
Unleaded 95 Unleaded 95 Unleaded 95 Unleaded 95
Unleaded Unleaded Unleaded Unleaded
FFL. S5 Diesel
S5
Diesel
S5
Diesel
S5
Diesel
0
NOOSA COUNCIL
PRELIMINARY ISSUE
LEADERBOARD LEADERBOARD LEADERBOARD LEADERBOARD PROVIDE 50mm WHITE
ENTRY ENTRY ENTRY ENTRY SPACE TO EITHER SIDE OF
3 SEPTEMBER 2018
TENANT 1
PECTEN SIGNAGE
PROPOSED SERVICE STATION (DETAILS TO BE CONFIRMED)
01 ELEVATION SHOP BUILDING
(DETAILS TO BE CONFIRMED) -
A800 1:100 @ A1
16/12/16
DATE
ISS
A
CANOPY PECTEN CANOPY LINK PROPOSED 7M PROPOSED CANOPY "SHELL WHITE"
BEYOND SECTION PYLON SIGN FASCIA PANEL APPLIED
300 NON-ILLUMINATED YELLOW/RED VINYL 300
PROPOSED RETAIL FUEL CANOPY
ACM COLUMN CLADDING TO
HOUSE D.P. AND CONDUIT
LINES TO BE "SHELL WHITE"
S3 1 2 S3 S3 3 4 S3 S3 5 6 S3 S3 7 8 S3
PRELIMINARY
ISSUED FOR
No No No No
FFL.
Entry
S6 Entry
S6 Entry
S6 Entry
S6
0
LEADERBOARD LEADERBOARD LEADERBOARD LEADERBOARD
EXIT EXIT EXIT EXIT
02 ELEVATION
A800 1:100 @ A1
Pylon approval sought is as per
DWG Coles Express Noosaville
QLD 5m by EVOCOM
PROPOSED 7M
PYLON SIGN PROPOSED CANOPY "SHELL WHITE" PROPOSED CANOPY "SHELL WHITE"
CANOPY PECTEN FASCIA PANEL WITH NON-ILLUMINATED FASCIA PANEL APPLIED
SIGNAGE "SHELL YELLOW" CURVED FASCIA STRIP NON-ILLUMINATED YELLOW/RED VINYL
S1 (ILLUMINATED) 300 300 AND ILLUMINATED "SHELL RED" BAR
CANOPY LINK
850
Unleaded
TENANT 1 (DETAILS TO BE CONFIRMED) Shell Licensee
max
Unleaded
95
S2 not
7000
FFL TO CANOPY U/S
Premium
98
5m Diesel
approved S2 S3
REFER NOTE 2 (TYP)
4700
U/S PUMP NUMBER
TRAFFIC
2700
REFER NOTE 1 (TYP) Studio 24/115 Wickham Street,
PO Box 724,
DIRECTION S5 S6 Fortitude Valley, QLD 4006
T: 1800 616 760
E: [email protected]
W: www.cadway.com.au
STRUCTURAL FOOTING
REFER TO ENGINEERS acn: 111 372 064 abn: 43 111 372 064
DETAILS
03 ELEVATION Pylon approval sought is as per
DWG Coles Express Noosaville
project description
A800 1:100 @ A1 VIVA NOOSAVILLE
QLD 5m by EVOCOM
PROPOSED SERVICE
8000
STATION DEVELOPMENT
project address
PROPOSED CANOPY "SHELL WHITE" 4000 4000 PROPOSED 7M 140-142 EUMUNDI ROAD
FASCIA PANEL APPLIED PYLON SIGN
NON-ILLUMINATED YELLOW/RED VINYL
NOOSAVILLE, QLD 4566
CANOPY LINK client
VIVA ENERGY PTY LTD
850
PROPOSED SERVICE STATION SHOP BUILDING Unleaded
Unleaded
95
S2 S2 not
FFL TO CANOPY U/S
Premium drawing title
98
TRAFFIC
REFER NOTE 2 (TYP) S3 approved Diesel SITE ELEVATIONS
4700
DIRECTION
REFER NOTE 1 (TYP)
S6 S5
1:100 @ A1 scale
09/12/16 date
JB drawn
04 ELEVATION CK checked
A800 1:100 @ A1
11147 job no.
0m 1 2 3 4 5
1:100 @A1 1:200 @A3 11147-A801 dwg no.
A issue
Page 3
2010
-
APPROVED PLANS
OPW18/0163
NOOSA COUNCIL
3 SEPTEMBER 2018
-
2000
10
Unleaded E10
1200
Unleaded
10
Diesel
595
10
595
Do not scale Customer Name Drawn BB
© Copyright 2017 All Dimensions in MM
from this Date 26/07/2017
This design / drawing remains the property drawing Viva Tolerances on Dimensions not
of EVOCOM and all rights strictly Revision 4 otherwise specified.
reserved. Reproduction either wholly or in
part / or issuance to third parties in any form Drawing Title Site Address:
Linear ± 0.1
whatsoever is strictly prohibited without the Angular ± 0.5°
written consent of EVOCOM. SHEET 1 OF 1 Coles Express Noosaville QLD 5m Hole Ctrs ± 0.1
Third Angle Orthographic Projection
Used in these records
OPW18-0163 Approved Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file