Original source · versioned page text
Acoustic report
Attached to the e-mail Response to Information Request - MCU18/0120, RAL18/0013, OPW18/0197.
Hass Holdings atf The Quasar Trust Environmental Noise Level Study for Proposed Industrial Business Type 2 (Production, Alteration, Repackaging and Repairing), 5 Taylor Court, Cooroy Page 8 of 17 NOISE LEVEL IMPACT The closest residences to the subject site (and separation distance from the closest part of the subject site) are as follows (as determined from site visit and Queensland Globe): • west, on the eastern side of Ferrells Road, approximately 470 metres; • east on the northern side of Nandroya Road, approximately 430 metres; • south-west on the eastern side of Ferrells Road, approximately 355 metres. All other residences are set back further than the above residences. Compliance with the noise limits at the above closest residences would also result in compliance with the noise limits at all other residential premises. Detailed below is the noise level impact to the closest residences to the west, east and south-west. Closest Residence to West At the closest residence to the west, on the eastern side of Ferrells Road, the noise level impact of the different noise sources are as per Table 3. Table 3 Source Noise Levels at Closest Residence to West Inside to Outside Source Noise Source Noise Distance Noise Source Industrial Shed, Level at Level, dB(A) Attenuation, dB(A) dB(A) Residence, dB(A) Car door closing 62 LAeq,adj,T @ 10m -35 0 27 Car engine starting 61 LAeq,adj,T @ 10m -35 0 26 Car driving 56 LAeq,adj,T @ 10m -35 0 21 Delivery truck 62 LAeq,adj,T @ 10m -35 0 27 Unloading/loading 60 LAeq,adj,T @ 10m -35 0 25 People talking 61 LAeq,adj,T @ 10m -35 0 26 Hand-held power saw 85 LAeq,adj,T @ 1m -56 -5 24 Power drill 80 LAeq,adj,T @ 1m -56 -5 19 Electric belt sander 88 LAeq,adj,T @ 1m -56 -5 27 Panel saw 85 LAeq,adj,T @ 1m -56 -5 24 100mm electric angle grinder 93 LAeq,adj,T @ 1m -56 -5 32 Welding 83 LAeq,adj,T @ 1m -56 -5 22 Compressor 83 LA90,T @ 1m -56 -5 22 Bench grinder 76 LAeq,adj,T @ 1m -56 -5 15 Combined noise of grinding, metal cut off saw, welding, radio and some 88 LAeq,adj,T @ 5m -42 -5 41 hammering Airconditioning units 76 LA90,T LWA -63 0 13 All of the above noise sources, including the combined noise level of grinding, metal cut off saw, welding, radio and some hammering, complies with the noise limits for the complete 24-hour day at the closest residence to the west, with no additional noise control measures required. David Moore & Associates Pty Ltd Our reference: R18062/D3342/Rev.0/25.09.18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original