Acoustic report

Attached to the e-mail Response to Information Request - MCU18/0120, RAL18/0013, OPW18/0197.

of 20

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Hass Holdings atf The Quasar Trust
Environmental Noise Level Study for Proposed Industrial Business Type 2 (Production, Alteration, Repackaging
and Repairing), 5 Taylor Court, Cooroy                                                                             Page 10 of 17




Closest Residence to South-West

At the closest residence to the south-west, on the eastern side of Ferrells Road, the noise level impact
of the different noise sources are as per Table 5.


                                                           Table 5
                                   Source Noise Levels at Closest Residence to South-West

                                                                                      Inside to Outside         Source Noise
                                             Source Noise             Distance
              Noise Source                                                             Industrial Shed,            Level at
                                             Level, dB(A)        Attenuation, dB(A)
                                                                                            dB(A)              Residence, dB(A)

Car door closing                           62 LAeq,adj,T @ 10m          -33                   0                      29
Car engine starting                        61 LAeq,adj,T @ 10m          -33                   0                      28
Car driving                                56 LAeq,adj,T @ 10m          -33                   0                      23
Delivery truck                             62 LAeq,adj,T @ 10m          -33                   0                      29
Unloading/loading                          60 LAeq,adj,T @ 10m          -33                   0                      27
People talking                             61 LAeq,adj,T @ 10m          -33                   0                      28
Hand-held power saw                         85 LAeq,adj,T @ 1m          -54                   -8                     23
Power drill                                 80 LAeq,adj,T @ 1m          -54                   -8                     18
Electric belt sander                        88 LAeq,adj,T @ 1m          -54                   -8                     26
Panel saw                                   85 LAeq,adj,T @ 1m          -54                   -8                     23
100mm electric angle grinder                93 LAeq,adj,T @ 1m          -54                   -8                     31
Welding                                     83 LAeq,adj,T @ 1m          -54                   -8                     21
Compressor                                   83 LA90,T @ 1m             -54                   -8                     21
Bench grinder                               76 LAeq,adj,T @ 1m          -54                   -8                     14
Combined noise of grinding, metal cut
off saw, welding, radio and some            88 LAeq,adj,T @ 5m          -40                   -8                     40
hammering
Airconditioning units                         76 LA90,T LWA             -61                   0                      15


All of the above noise sources, including the combined noise level of grinding, metal cut off saw,
welding, radio and some hammering, complies with the noise limits for the complete 24-hour day at the
closest residence to the west, with no additional noise control measures required.


NOISE CONTROL MEASURES

As the noise limits are complied with for the complete 24-hour period, at all of the closest residences, no
additional noise control measures are required for the proposed industrial sheds.


CONCLUSIONS

It is proposed to develop the currently vacant subject site at 5 Taylor Court, Cooroy with industrial
sheds. Potential noise sources associated with these proposed industrial sheds could include:

•    delivery vehicles, both raw materials and finished product;
•    passenger vehicle movements on site;
•    manufacturing machinery, including both metalwork and woodwork;
•    motor vehicle repairs; and
•    plant and equipment.




David Moore & Associates Pty Ltd                                                 Our reference: R18062/D3342/Rev.0/25.09.18
Log in to download the original file

Acoustic report.pdf · 918 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.