Original source · versioned page text
220527 Sight Distance Assessment and IR Responses
Attached to the e-mail Response to Information Request OPW22/0117 - 38 Tristania Dr Marcus Beach.
Figure 4 – Available sight distance to the west from the proposed vehicle crossover
Figure 5 – Available sight distance to the east from the proposed vehicle crossover
Table 1 below details the: -
• relevant design speed
• minimum domestic driveway sight distance (from Figure 3.2 AS2890.1); and
• current available sight distance (measured on site).
Table 1 – AS2890.1 required sight distance and available sight distance for the proposed
vehicle crossover
Sight distance Design speed / speed limit Min sight distance for Available sight
direction (km/hr) Min domestic properties (m) distance (m)
North East 40 30 33
South East 40 30 30
West 40 30 70
Figure 6 overleaf further explains the “Sight Distance Direction” that is referred to in Table
1.