7. Provide details of building height on the elevation plans of the Community
Building Village Centre.
8. Provide roof plans for the Residential Aged Care and Community buildings,
Apartment 1 & 2, and Independent Living Units demonstrating the extent of roof
pitching and roof overhangs. Justify roof pitching less than 12 degrees.
Building Setbacks
9. Schedule 1 of The Noosa Plan stipulates a minimum setback of 6 metres to road
frontages for development in the Community Services Zone and also for Multiple
Housing – Type 3 Retirement and Special Needs use. Accordingly, demonstrate
how the proposal meets this provision, as the master plan currently shows only a
4.5 metre setback to Elm Street, which is unacceptable given it forms part of the
Shire’s major road network.
Building Articulation
10. Independent Living Units, particularly designs A3-B have designs which include
facades in excess of 15 metres in length without any articulation or variation.
These building designs shall incorporate staggering or separating continuous
walls into smaller sections to improve the visual amenity for residents of the other
Independent Living Units, which directly face these blank walls.
Visual and Acoustic Amenity
11. The report adopts an indoor noise limit of 40dBA (LAeq), which corresponds to the
Maximum recommended level in AS2107 for a bedroom adjacent to a major
road. Considering that the Standard defines the Maximum level as the noise
level at which most people would become annoyed, Council requires a safety
margin to be built into the assessment. Accordingly, Council requires the
assessment to be based on the following internal noise criteria:
Bedrooms 35dBA (LAeq) over the loudest hour between 10pm and 6am.
Bedrooms and other living spaces 40dBA (LAeq) over the loudest hour
between 6am and 10pm.
12. The report at Section 4.6.4 incorrectly suggests that the required STC rating for
dwelling facades is determined as the TNR +6. The Consultant is referred to
Clauses 3.4.2.6 and 3.4.3.1 of AS3671 for a correct determination of the STC
requirements. The building attenuation requirement shall be reassessed in
accordance with the Standard, either based on worst-case exposures which
would then apply to the entire site, or to a range of different noise exposures.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request for Further Information - 010.2007.00002398.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 25 KB (small file)
- File type
No other editions are linked here.