Bottom Plates 35x90 MGP1O | 29 |
Bi Beorer 295x85 Hynebeam 17C con/span | fa |
wo a :
i “oO, t= Railing to owner] |selection I
16mm Comp FC sheet wet sealed & tiled v4 =
Deck Joists 245x45 Hyne LCL | a K —r lr -
External grade @ 450 crs - | Te { 3
Approved type hangers & framing anchors voy aH co t— 2/300x45 Hyne LGL joists
3/30x2.8 nails per leg \ f w a Over entry way
{Awning roof ~H : = Ti a LJ fl H Uy L \ U |i
90x90 Gal SHS post
Replace Bhlustrade with <= Approved type balustrade Proposed aaraae _
Approved lass balustrade T] LL To go on stairs P gorag Existing block retaining wail
[ < i
NS o
f ran ‘ , a { 7
, s —
» Existing Patio“ x lf aot
“ + t LI oe
Existing slab WI? Proposed stab “Sh \ ae
Stairs to comply to BCA Part 3.9.1 [Ay a “ Posi Joists PJ30-70 MGPI2 @ 450 crs
Balustrades to comply to BCA Port 3.9.2 CY “ wd ae ”
go ae : : . .
3 _—_ aw Existing Brick veneer wall — Footings slab & connection to existing slab to Engineers details.
“ _ = _- Existing stoir wel To be removed Termite protection to AS3660.1, 200um polyfilm to underside of
y 2 slab. 50mm clean sand fill under slab
oo 4
Lo “ LIC No 077586
Natural Ground “~ Replace existing SHS post & patio refer to Engineer ADRIAN BAKER COMPUTER DRAFTING

—

—

PFC Steel roof structure to be designed
By Engineers and Manufactures
To W50 N3 wind categor

30mm gol looped strap a top plate
4/Approved type tek screws or nails per leg

Top Plotes 2/45x90 MGP1O

Studs 35x90 MGPIO @ 450 8

Mi2 Tie-down rods @ 1200 crs OK

   

3° pitch

8 Mtrs above Nature! ground ——__—- ~~

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

        

Kitchen designed by others a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 | NOTE: Builder to determine oll dimensions on
Site to coincide with existing building

Builder to ensure the 8M mox height
Above natural ground is not exceeded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Studs 45x90 MGPIO @ 450 crs
————When studs greater than 3200mm in height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPICAL SECTION A/A SCALE 1:50 (REFER TO ATTACHED STRUCTURAL ENGINEER CHANGES)

 

 

 

 

 

 

 

 

 

 

 

 

 

Residential

Ph: 07 5447 3372

Office 1, 36 Duke Street , Sunshine Beach , Queensland

Design Division

Fox 07 54473416

 

EMAIL: — [email protected] au

 

 

 

 

PROPOSED TIMBER FRAMED UPPER FLOOR ADD

ITION & ALTERATIONS TO EXISTING BRICK DWELLING

 

 

 

 

FOR:— TONY JACKSON OF AJJ DEVELOPMENTS

Lot No: 78

25 ARKANA DRIVE NOOSA HEADS

LOT No 78 SHIRE OF NOOSA
DATE: Ds

02/03/2007 SCALE 1:50

CHK.

CHK. BY TONG. BY) SHEET No 6 of 9
REF. No 0606S

 

 

DESIGN STRENGTH W41 N3

 

 

 

Used in these records

About this file

File size
3.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0545 - Preliminary Building Works assessable against the Planning Code [As Published].pdf · 3.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.