32231 Crisp - Preliminary Working Drawings · MCU16/0046
Attached to the e-mail MCU16/0046 Application - 25/512 David Low Way, Castaways Beach.
KEY: NOTES:
MAIN SWITCHBOARD 1. PROVIDE 3 PHASE SUPPLY FROM STREET.
SUB BOARD 2. PLACE ALL POWER POINTS AND OUTLETS TO
NETWORK DISTRIBUTOR SUIT CABINETRY AND/OR FITTINGS. REMAINING
POWER POINTS AND OUTLETS TO BE MOUNTED
DOUBLE GPO 300mm AFFL.
SINGLE GPO 3. PROVIDE SUPPLY TO A/C UNITS AS REQUIRED. DRIVEWAY
DOUBLE DATA/PHONE OUTLET 4. PROVIDE SEPERATE CIRCUIT FOR FRIDGE.
SINGLE DATA/PHONE OUTLET
TV OUTLET
INTERCOM POWER PLAN SHOULD BE READ IN 300 300
SECURITY SENSOR CONJUNCTION WITH JOINERY PLANS
FOR MORE DETAILED POWER POINT
CCTV CAMERA PLACEMENT
300
BED 2
1500 TBC GARAGE
300
CEILING MOUNTED
FOR GARAGE DOOR
BED 3
300 E
ROB
300
1500 TBC
BE
1500 TBC
RO
1000
BED 4
BATH LAUNDRY DRYING
BE
1000
RO
300 300 1300 300
POOL ABOVE
KEY: NOTES:
FLOURESENT TUBE LIGHT INTERNAL WALL LIGHT 1. PROVIDE 3 PHASE SUPPLY FROM STREET. * TOTAL INTERNAL LED STRIP
L S LIGHTING APPROXIMATELY 79m
LED STRIP LIGHTING STAIR WALL LIGHT 2. PLACE ALL LIGHT SWITCHES AT 1100mm AFFL.
DL
DIRECTIONAL LED STRIP E EXTERNAL WALL LIGHT
3. PLACE ALL POWEWR POINTS AND OUTLETS TO SUIT CABINETRY AND/OR * TOTAL EXTERNAL LED STRIP
LV FITTINGS. REMAINING POWER POINTS AND OUTLETS TO BE MOUNTED 300mm AFFL.
LV DOWNIGHT D UP/DOWN WALL LIGHT LIGHTING APPROXIMATELY 105m
D 4. PROVIDE SUPPLY TO A/C UNITS AS REQUIRED.
LED DOWNLIGHT P POOL/POND LIGHT
P
PENDANT LIGHT
EXHAUST FAN
5. PROVIDE SEPERATE CIRCUIT FOR FRIDGE.
UP
DRIVEWAY
G
LV GARDEN LIGHT 6. ENERGY EFFICIENT LIGHTING TO BE INSTALLED TO A MINIMUM OF 80% OF TOTAL
MOTION SENSOR FIXED LIGHTING POSITIONS. (BASED ON NUMBER OF LIGHTS INSTALLED INTERNALLY
U
RECESSED LED UP LIGHT & IN OUTDOOR COVERED AREAS).
SD
X
3
SMOKE DETECTOR
W
POND LIGHT IMMERSED TD 7. SEE JOINERY DETAILS FOR LOCATION & EXTENT
THERMAL DETECTOR OF LED STRIP LIGHTING.
SP
DIRECTIONAL SPOTLIGHT X SWITCH 8. GARDEN LIGHTS TO BE ON MOTION SENSORS.
CEILING FAN 2 2-WAY D
9. GARDEN LIGHTS TO FUTURE DETAIL. D
3 3-WAY
ENERGY EFFICIENT LIGHTING REQUIRED - 80% BED 2
D DIMMER
ENERGY EFFICIENT LIGHTING PROVIDED - 100%
SWITCHWIRE
GARAGE
D
D D
E
ROB
XX
X
D
BED 3 D
XX
X
BE
3
X
RO
D D
X XX
XX
XX D
BED 4 DRYING
D
D BATH LAUNDRY
BE
D
D
RO
D
LED (2.1m) TO UNDERSIDE
OF MIRROR (SJD)
POOL ABOVE
CLIENT: Graham Hennessy & Sandra Crisp PROJECT: Noosa Dunes Project
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot 25 on SP111721 25 Marcus Dune Ct, CASTAWAYS BEACH QLD 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: LOWER ELECTRICAL AND LIGHTING
P: (07) 54748 107 be read in conjunction with engineers design and details, the
accompanying building specification and schedule of finishes. If in DATE: 25/09/15 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
F: (07) 54748 108 BSA LICENCE: 1127508
doubt, please request clarification. DO NOT ASSUME.
ISSUE: PRELIMINARY WORKING DRAWINGS
WD12.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
32231 Crisp - Preliminary Working Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.9 MB (small file)
- File type
No other editions are linked here.