EXAMPLE -CCTV Re Pakt

 

Conduit Inspection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date: Asset owner's job ref.: Asset Owner: Operator : Section number: Pipe Asset Id:
9/07/2016 UNITY 1 2536517
Time of inspection: Cleaning: Standard: LRP. Conduit Unit Length Method of Inspection
13:30:22 not cleaned WSA 05-2008 2.2 Inside Face of the Wall 0.90 m Television Camera
Town: Catchment: US MH: 2668647
Suburb: Client: Survey Dir: upstream
Street: Precipitation.: No DS MH: 2668594
Asset Location Private Property Flow control No measures Inspect Lenght: 63.60 m
Purpose of inspection: Buildover Shape : Circular
Use of Conduit: Sewage Dia/Height: 1560 mm
Type of Conduit: Gravity Width:
Lining Method: Pipe Material: Vitrified clay
Remarks
1:435 Position Code Observation MPEG Photo Grade
66859:
0.00 STMH _ Start node, maintenance hole, Nodename: 2668594 00:00:32 0
0.00 WLC Water level, clear flow (the invert is visible) 00:00:33 0
20.36 IR Infiltration, Running--a continuous flow , at 4 o'clock 00:05:37 1_3A, 1
1_3B
MC Change of conduit material. New material, u-PVC 00:14:19 1_4A 0
RF Fine roots--a relatively small number of flexible minor roots 00:14:23. 1_5A 41
, feduction in cross sectional area, at joint, Obstruction:
<5% , from 8 to 9 o'clock
JIRN Jointing material intrusion, Seal visibly displaced/damaged 00:14:59 1_6A 3
but not intruding into conduit , from 10 to 12 o'clock
JNGO — Junction open, good workmanship, diameter 100mm _, at 2 00:11:59 1_4A, 0
o'clock 1_4B
MC Change of conduit material. New material, Vitrified Clay 00:16:26 0
MC Change of conduit material. New material, u-PVC 00:18:18 4_9A 0
JNGO — Junction open, good workmanship, diameter 100mm _, at 2 00:18:45 1_10A, 0
o'clock 1_10B
A 47.99 MC Change of conduit material. New material, Vitrified Clay 00:20:17 0
53.19 RM A Mass of mostly fine Roots, which has developed into an 00:21:59 1_12A 3
interwoven clump, at joint, Obstruction: 5-20%,
Lf @MANHOLE, from 4 to 8 o'clock
e6B64 53.50 FHMH _ Finish node, maintenance hole, Nodename: 2668647 00:22:42 0
STR no def STR peak STR mean STR total STR grade SER no def SER peak SER mean SER total SER grade
0 0 0 0 1 4 30 0.99 53 3

 

 

 

 

 

 

 

 

 

 

 

 
Log in to download the original file

Attachment 1 - Information Request Response.pdf · 5.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.