Log in to see the plans as drawnPEREGIAN BEACH VILLAS
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
Sheet Index
Layout ID Layout Name Published -
Sheet Index
A.01.1 COVER PAGE
NOOSA COUNCIL
A.01.2 GROUND FLOOR APPROVED PLANS
A.01.3 FIRST FLOOR
A.01.4 ELEVATIONS
MCU14/0008 26 JUN 2014
A.01.5 ELEVATIONS
NOTES
INSERT SKETCH RENDER
FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS
AREAS
GENERAL NOTES GROSS FLOOR AREA
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 8: 55m2
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 9: 55 m2
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SCHEDULES OF FINISHES.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Collins Developments
DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398
facsimilie
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected]
FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u