MCU14/0008 Approved Plans
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnGENERAL NOTES PEREGIAN BEACH VILLAS UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND SCHEDULES OF FINISHES. DIMENSIONS TAKE PRECEDENCE OVER SCALE. DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES DIRECTLY TO THE SUPERINTENDENT. REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. 5,030 5,030 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE WITH THE B.C.A. 90 1,725 90 3,000 250 3,000 90 1,725 90 ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS2208 AND THE DESIGN CONDITIONS AS NOMINATED. 990 90 735 1,090 90 1,910 250 1,910 90 1,090 725 90 1,000 BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT 440 440 THE ENTRY OF MOISTURE INTO THE BUILDING. CL CL WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION Patio 3.8.1 OF THE B.C.A AND AS 3740 Patio 1,000 1,000 1.0 x 4.9 930 930 1.0 x 4.9 ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN STANDARDS. 90 90 90 90 REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH 2,480 2,480 Ens Bed Bed Ens AS3788 & PART 3.72 OF THE BCA 3,300 3,300 2.5 x 1.7 3.3 x 3.0 3.3 x 3.0 2.5 x 1.7 CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING WC WC MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 90 90 Bi-fold doors by AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL REQUIREMENTS cabinet maker 820 820 16 16 W W 90 90 15 Laundry Laundry 15 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET 14 under under AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER T ROBE ROBE T 14 550 550 13 stair stair 13 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS 12 12 FOR MEMBER SIZES 90 90 LEGEND 11 11 11,340 11,340 10 UNIT 9 UNIT 8 10 9 9 A/C AIR CONDITIONING AS SPEC. - INSTALLED 3,580 3,580 8 8 BY CONTRACTOR 7 7 AP 450 X450 REMOVABLE ACCESS 6 6 PANEL - LOCATION TO BE CONFIRMED ON SITE 5 5 BL CONC. BLOCK WALL TO STRUCTURAL ENG. 4 4 DETAIL - RENDER AND PAINT AS SPEC. 3 3 CF COLORBOND FLASHING TO DETAIL 2 2 CJ CLADDING CONTROL JOINT - REFER ELEVATIONS Single Garage Single Garage CONC CONCRETE SLAB TO ENG. DETAIL 6,000 6,000 1 1 6.0 x 3.3 6.0 x 3.3 CPD CUPBOARD DP 90mm DIA DOWNPIPE AS SPEC. 1,210 1,210 REFER TO DETAILS FOR TYPICAL FIXING DRY CLOTHES DRYER DW DISHWASHER EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH 90 90 GUTTER BRACKETS @ MAX 900 CRS EGL EXISTING GROUNDLINE F REFRIGERATOR 1,980 1,980 FW FLOOR WASTE GD S.S GRATED DRAIN AS SPEC. HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION 90 90 HP HOT PLATES AS SPEC. HWU HOT WATER 130 130 MR MECHANICAL RISER MW MICROWAVE 90 NGL NATURAL GROUND LINE Timber fence 900 90 3,825 250 3,815 90 1,000 OV OVEN P PANTRY PGL PROPOSED GROUNDLINE 90 1,425 90 3,300 250 3,300 90 1,425 90 PTF POLISHED TIMBER FLOOR AS SPEC. RHS RHS TO STRUCTURAL. ENG. DETAIL RV "WIRILY BIRD" OR SIM. APPROVED 5,030 5,030 S SINK SD HARDWIRED SMOKE DETECTOR TO COMPLY WITH A.S. 3786-1993 SHR SHOWER TO DETAIL - SHS SHS TO STRUCTURAL. ENG. DETAIL SL SKYLIGHT AS SPEC. NOOSA COUNCIL T TUB T-1 INTERNAL TILE AS SPEC. APPROVED PLANS T-2 TD EXTERNAL TILE AS SPEC. HWD TIMBER DECKING AS SPEC. TOW TOP OF WALL MCU14/0008 26 JUN 2014 VAC IN-BUILT VACUUM SYSTEM AS SPEC. VB VANITY BASIN WC TOILET SUITE WF COLORBOND WALL FLASHING WM WASHING MACHINE Amendments Wind Rating Checked By: Status: PR Date: 20.03.14 PEREGIAN BEACH VILLAS D 16.01.14 Amend GFA CT Scale: 1:100 @ A3 Drawn by: CT Client Signiture Approval: E 22.01.14 Client request amendments CT Client Initials: TBC ALEX CHARLWOOD Drawing Title: F 24.01.14 Client request amendments CT Date: UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, G 07.02.14 Amend areas & Kitchen layout CT PH: 0410 650 745 GROUND FLOOR BSB No.: 1043429 H 25.02.14 Amend design CT NOTES: ABN: 59 980 573 352 Client: Drawing No.: PR Drawings by HINTON STEEL FRAME QLD PTY LTD. I J 04.03.14 Amend design & balcony 20.03.14 Amend design & Areas CT CT ECO REMOTE A.01.2 J ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.