MCU14/0008 Approved Plans

of 23

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
Sheet Index
Layout ID              Layout Name                            Published
                       Sheet Index
A.01.1                 COVER PAGE                                                                                                                                                                                                      -
A.01.2                 GROUND FLOOR                                                                                                                                                                             NOOSA COUNCIL
A.01.3                 FIRST FLOOR
A.01.4                 ELEVATIONS
                                                                                                                                                                                                               APPROVED PLANS
A.01.5                 ELEVATIONS                                                                                                                                                                            MCU14/0008 26 JUN 2014
NOTES




                                                                    FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS

                                                                                                                                                                                                                                                     AREAS
GENERAL NOTES                                                                                                                                                                                                     GROSS FLOOR AREA
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL     PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE   ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL                                       UNIT 1:                                                 55 m2
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON   WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.              AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.                                                                             STANDARDS.                                                                               UNIT 2:                                                 55 m2
                                                             STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE                                                                                                UNIT 3:                                                 55 m2
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND    WITH THE B.C.A.                                             REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SCHEDULES OF FINISHES.
                                                             ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND       SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
DIMENSIONS TAKE PRECEDENCE OVER SCALE.                       AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND      AS3788 & PART 3.72 OF THE BCA
                                                             AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES                                                                      CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING


                                                                                                                                                                                      Collins Developments
DIRECTLY TO THE SUPERINTENDENT.                              BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING                                                                                             HINTON STEEL FRAMES
                                                             AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT      MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm                                16 Computer Road Yatala
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,     THE ENTRY OF MOISTURE INTO THE BUILDING.                    AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL                                           Gold Coast
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.                                                                  REQUIREMENTS                                                                              qld australia 4207
                                                             WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION                                                                                                 telephone
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.    3.8.1 OF THE B.C.A AND AS 3740                              SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET                                  (617) 3287 3398
                                                                                                                                                                                                                   facsimilie
                                                                                                                         AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER                                      (617) 3382 7656
                                                                                                                         FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS                                   email: [email protected]
                                                                                                                         FOR MEMBER SIZES                                                                          w w w .h i n t o n s t e e l f r a m e s .c o m .a u
Log in to download the original file

MCU14_0008 APPROVED PLANS.pdf · 2.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.