Altum Constructions Environmental Noise Level Impact Assessment of Facilities Building, Including Internal Dining Option, Parkridge, 75 Resort Drive, Noosa Heads Page 11 of 22 ADOPTED NOISE LIMITS Based on the above and the fact that all of the closest residential are apartment buildings, the noise limits which have been adopted in this report, for immediately outside a residential apartment, are as described by Condition 81 of the Noosa Council approval for steady state noise and, for time varying noise sources, as follows: Steady State Noise Source • daytime (0700 to 1900 hours): 45 dB(A) LAeq,adj,T; • evening (1900 to 2200 hours): 39 dB(A) LAe,adj,T; • night-time (2200 hours to midnight): 36 dB(A) LAeq,adj,T. Time Varying Noise Source • daytime (0700 to 1800 hours): 45 + 5 = 50 dB(A) LAeq,adj,T; • evening (1800m to 2200 hours): 39 + 5 = 44 dB(A) LAe,adj,T; • night-time (2200 hours to midnight): 36 + 5 = 41 dB(A) LAeq,adj,T. PLANT AND EQUIPMENT For the Facilities Building all of the plant and equipment is located on the roof plant deck. On the western side of the plant deck a Sonic Series 100 acoustic louvre has been installed with an insertion loss of: • 63 Hz: - • 125 Hz: 4 dB; • 250 Hz: 5 dB; • 500 Hz: 8 dB; • 1000 Hz: 12 dB; • 2000 Hz: 16 dB; • 4000 Hz: 15 dB. All sides of the roof top plant deck has differing height masonry nib walls, ranging from 800 mm to 1600 mm high. The plant and equipment located on the plant deck is as follows: • kitchen exhaust fan; • Daikin RXYQ8AYM; • Daikin RXYQ16AYM (gymnasium); • Daikin RXYMQ4AV4A (two of); • Glacier GC 301-B-2.7 (two of); • MINT HUCE22-1M; • MINT HUCE-1L. In addition to the above there will be an additional four air-conditioning units located on the roof of the pizza bar (near the pizza oven), which service the dining area when it is enclosed. These air- conditioning units are Daikin model number RZAV140CV1 with a sound power level of 75 dB(A) LWA each for normal mode and 71 dB(A) LWA for the night quiet mode. The separation distance of these four air-conditioning units to the closest residential – Block 3 – and the quieter night-time mode will ensure that the noise of these additional air-conditioning units, in conjunction with all other plant and equipment, will comply with the daytime, evening and night-time noise limits, for their associated hours of operation (up to midnight). David Moore & Associates Pty Ltd Our reference: R21054/D3422/Rev.0/25.08.21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Noise Impact Assessment and Noise Managment Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.