Council archive · source document
Appendix C - Noise Impact Assessment and Noise Managment Plan · 132005.1133.15
Plans and drawings: the text below has words only, no drawings.
Altum Constructions Environmental Noise Level Impact Assessment of Facilities Building, Including Internal Dining Option, Parkridge, 75 Resort Drive, Noosa Heads Page 14 of 22 GYMNASIUM There is potential for noise from within the gymnasium to impact the closest residential Block, in particular Blocks 3 and 4. The gymnasium is fully air-conditioned and it has been assumed that it will only be ever operated with all external openings closed. From a previous noise assessment conducted inside a gymnasium for a 48-hour period the noise levels were: • average up to 72 dB(A) LAeq,15min; • maximum up to 88 dB(A). The noise limits for noise from the gymnasium, at the closest residential, is: • daytime (0700 to 1800 hours): 50 dB(A) LAeq,adj,T; • evening (1800m to 2200 hours): 44 dB(A) LAe,adj,T; • night-time (2200 hours to midnight): 41 dB(A) LAeq,adj,T. The external structure of the gymnasium building will reduce noise levels from inside the gymnasium to the closest residential as follows: • 72 dB(A) LAeq,adj,15min – 20 (inside to outside gymnasium building, external; openings closed) – 10 (distance to closest residential apartment) = 32 dB(A) LAeq,adj,T. Provided the external openings are closed noise from inside the gymnasium complies with the noise limits for the complete 24-hour day. DELIVERY VEHICLES From previous noise assessments conducted of different commercial facilities, the typical noise of a refrigerated delivery vehicle (up to 4.5 tonne) is 79 dB(A) LWA. This includes the truck arriving, doors opening and closing, unloading, and departing. The closest residential apartment to the loading bay/waste collection bay (bay 21, site plan refers) is Block 3, Apartment T8, with a separation distance of approximately 15 metres (refer site plan, Figure 2 of this report). At this separation distance the noise of the delivery vehicle will be 79 dB(A) LWA – 32 (separation distance) = 47 dB(A) LAeq,adj,15min. This is a time varying noise source and complied with the daytime noise limit of 50 dB(A) LAeq,adj,15min, but exceeds the evening and night-time noise limits of 44 and 41 dB(A) LAeq,adj,15min respectively. To ensure compliance with the noise limits delivery vehicles should be limited to accessing the Facilities Building during the daytime only, from 0700 to 1800 hours. WASTE COLLECTION From previous noise assessments conducted of waste collection vehicles (for wheeled plastic bins) the typical noise level (adjusted to be equivalent to a 15-minute period) is 81 dB(A) LWA. This includes the truck arriving, bins being emptied, and departing. The closest residential apartment to the loading bay/waste collection bay (bay 21, site plan refers) is Block 3, Apartment T8, with a separation distance of approximately 15 metres (refer site plan, Figure 2 of this report). At this separation distance the noise of the delivery vehicle will be 81 dB(A) LWA – 32 (separation distance) = 49 dB(A) LAeq,adj,15min. This is a time varying noise source and complied with the daytime noise limit of 50 dB(A) LAeq,adj,15min, but exceeds the evening and night-time noise limits of 44 and 41 dB(A) LAeq,adj,15min respectively. David Moore & Associates Pty Ltd Our reference: R21054/D3422/Rev.0/25.08.21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Noise Impact Assessment and Noise Managment Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.