Council archive · source document
Appendix C - Noise Impact Assessment and Noise Managment Plan · 132005.1133.15
Plans and drawings: the text below has words only, no drawings.
Altum Constructions Noise Management Plan Prepared For Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads And Page 1 of 13 Incorporating Dining Area Which Can Be Fully Enclosed INTRODUCTION This Noise Management Plan has been prepared for the Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads, aspects of which have the potential to noise impact the occupants of the nearby residential apartment buildings. This Facilities Building comprises: • internal dining area; • pizza bar; • room for cooking classes; • gymnasium, room 1 and room 2; • convenience store; • kitchen; • office; • amenities. It should be noted that, originally, all of the dining was outdoors (with most of the outdoor dining area under cover but with no external walls). This outdoor dining area is to be refurbished and extensive glazing added so that the dining area can be either an outdoor dining area or, when all of the windows and operable walls are closed, an air-conditioned internal dining area. By closing all of the windows and operable walls to the dining area patron noise and amplified entertainment noise will be controlled to acceptable noise levels to all of the closest residential and permit the dining area to be able to trade until midnight. Potential noise sources associated with the Facilities Building are: • plant and equipment, which includes air-conditioning, refrigeration and exhaust fans; • delivery vehicles; • waste collection; • patron noise; and • amplified music. The proposed hours of operation of the dining area of the Facilities Building is 0600 hours to midnight, daily. For details of all of the potential noise sources and their associated source noise levels, noise limits, calculated noise level impact at the closest residential and required noise control measures, refer to the David Moore & Associates Pty Ltd report titled Environmental Noise Level Impact Assessment of Facilities Building, Including Indoor Dining Option, Parkridge, 75 Resort Drive, Noosa Heads conducted for Altum Constructions, Report R21054/D3422/Rev.3/24.08.2021. Refer Figure 1 for the location of the Facilities Building relative to all on-site residential for Parkridge. Compliance with the noise limits at the on-site Parkridge residential would also result in noise limit compliance at all other nearby residential. Figure 2 is the proposed Level 1 floor plan for the Facilities Building, Figure 3 the proposed seating plan for the dining area and Figure 4 the proposed upper level 1 floor plan for the Facilities Building. OBJECTIVE This Noise Management Plan establishes the noise limits for the Facilities Building, together with the requirements to achieve compliance with these noise limits at all of the closest residential. David Moore & Associates Pty Ltd Our reference: R21055/D3295/Rev.0/25.08.21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Noise Impact Assessment and Noise Managment Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.