Appendix C - Noise Impact Assessment and Noise Managment Plan · 132005.1133.15
Plans and drawings: the text below has words only, no drawings.
Altum Constructions Environmental Noise Level Impact Assessment of Facilities Building, Including Internal Dining Option, Parkridge, 75 Resort Drive, Noosa Heads Page 1 of 22 INTRODUCTION The Parkridge development includes a Facilities Building at 75 Resort Drive, Noosa Heads. This Facilities Building comprises: • internal dining area; • pizza bar; • room for cooking classes; • gymnasium, room 1 and room 2; • convenience store; • kitchen; • office; • amenities. It should be noted that, originally, all of the dining was outdoors (with most of the dining area under cover but with no external walls). This dining area is to be refurbished and extensive glazing added so that the dining area can be either an outdoor dining area or, when all of the windows and operable walls are closed, an air-conditioned internal dining area. By closing all of the windows and operable walls to the dining area patron noise and amplified entertainment noise will be controlled to acceptable noise levels to all of the closest residential and permit the internal dining area to be able to trade until midnight. The proposed hours of operation of the dining area of the Facilities Building are 0600 hours to midnight, daily. All of the plant and equipment for this Facilities Building are located within a dedicated rooftop plant deck or on the roof above the new pizza bar. With respect to the Facilities Building, potential noise sources include: 1. plant and equipment; 2. gymnasium equipment; 3. patron noise; 4. amplified music; 5. delivery vehicles; 6. waste collection. Each of these potential noise sources has been calculated to the closest residential and compared to the noise limits. In those instances where the noise limits are not complied with suitable noise control measures have been nominated, namely the ability to enclose the dining area by closing all of the windows and operable walls. Refer Figure 1 for the location of the Facilities Building relative to all on-site residential for Parkridge. Compliance with the noise limits at the on-site Parkridge residential would also result in noise limit compliance at all other nearby residential. Figure 2 is the proposed Level 1 floor plan for the Facilities Building, Figure 3 the proposed seating plan for the indoor dining area and Figure 4 the proposed upper level 1 floor plan for the Facilities Building. In preparing this report the architectural drawings prepared by Blackburne Jackson, project number 5737, were referenced, namely: • drawing DA04, 37: Proposed Precinct F Development, Noosa Heads, Ground Floor; • drawing DA02-01, 06: Parkridge Facilities Building Upgrades – Level 1 Floor Plan; • drawing DA02-02, 04: Parkridge Facilities Building Upgrades – Upper Level 1 Floor Plan; • drawing DA02-03, 01: Parkridge Facilities Building Upgrades – Roof Plan; • drawing A02-21, 03: Facilities Building – Level 1 Floor Plan; • drawing DA04-01, 04: Parkridge Facilities Building Upgrades – Elevations; • drawing DA05-01, 01: Parkridge Facilities Building Upgrades – Sections; • drawing DA17-01, 05: Parkridge Facilities Building Upgrades – Perspective Views. David Moore & Associates Pty Ltd Our reference: R21054/D3422/Rev.0/25.08.21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Noise Impact Assessment and Noise Managment Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.