DYNAMIC CONE PENETRATION TEST RESULTS
Client:       WEMEAR MADOC PTY LTD
Project:      PROPOSED ALTERATIONS AND ADDITIONS
Location:     LOT 1, BAYVIEW ROAD, NOOSA HEADS, QLD
Job No.       37032UR                          Hammer Weight & Drop: 9kg/510mm
Date:         18-9-24                          Rod Diameter: 16mm
Tested By:    C.S.                             Point Diameter: 20mm
Test Location     101          102             Test Location
 Surface RL        N/A         N/A              Surface RL
 Depth (mm)        Blows per 100mm Penetration  Depth (mm)        Blows per 100mm Penetration
 6000-6100          7           8               9000-9100
 6100-6200          7           8               9100-9200
 6200-6300          6           9               9200-9300
 6300-6400          6           9               9300-9400
 6400-6500          6           9               9400-9500
 6500-6600          7           9               9500-9600
 6600-6700          8           10              9600-9700
 6700-6800         10           8               9700-9800
 6800-6900          7           8               9800-9900
 6900-7000          7           7               9900-10000
 7000-7100          6           7              10000-10100
 7100-7200          6           6              10100-10200
 7200-7300          7           7              10200-10300
 7300-7400          6           7              10300-10400
 7400-7500          9           8              10400-10500
 7500-7600         12           8              10500-10600
 7600-7700         11           9              10600-10700
 7700-7800         12           10             10700-10800
 7800-7900         13           10             10800-10900
 7900-8000         13           10             10900-11000
 8000-8100        END          END             11000-11100
 8100-8200                                     11100-11200
 8200-8300                                     11200-11300
 8300-8400                                     11300-11400
 8400-8500                                     11400-11500
 8500-8600                                     11500-11600
 8600-8700                                     11600-11700
 8700-8800                                     11700-11800
 8500-8900                                     11800-11900
 8900-9000                                     11900-12000
Remarks:             1. The procedure used for this test is described in AS1289.6.3.2-1997 (R2013)
                     2. Usually 8 blows per 20mm is taken as refusal


Ref: JK Geotechnics DCP 0-12m Rev5 Feb19

Used in these records

About this file

File size
6.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

geotech report.pdf · 6.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.