4.2 Subsurface Conditions Based on our review of the provided ASI ‘Soil Test Report’ and our DCP test results, we conclude that the encountered subsurface profile comprises an intermittent limited thickness of fill with the Pleistocene age sand dune deposits either underlying the fill or present from surface level. Groundwater and bedrock were not encountered within the depth of our investigation and the previous ASI investigation. A summary of the pertinent subsurface conditions is presented below and for further details reference should be made to the previous ASI ‘Soil Test Report’ and the attached DCP test results. Fill ASI BH1 encountered poorly compacted sandy fill which extended to 0.4m depth. We note that the ASI investigation was completed before the existing house and surrounding landscaping was completed so it is likely that greater thicknesses of fill are present in localised areas of the site where flat terraces have been formed on the downslope sides of the property and supported by landscape retaining walls. We also note that during the fieldwork, the owner indicated to our geotechnical engineer that in the area of the proposed lift pit, excavations had been completed to accommodate the original house construction, and was backfilled on completion of construction. On this basis, and assuming a sandy fill profile, we have interpreted the results of DCP101 to indicate poorly compacted fill. We note that in the absence of formal records of placement and density test results and considering the fill has been assessed to be poorly compacted, the fill is regarded as ‘uncontrolled’ as defined in AS2870-2011 ‘Residential slabs and footings’ (AS2870-2011). Natural Dune Sands In the ASI boreholes, natural dune silty sands were encountered below the fill (BH1) or from surface level (BH2) and extended to the termination depth of the boreholes at 9.3m. Based on our interpretation of the ASI DCP test results the sands were initially of very loose relative density improving to loose below about 1.5m to 1.6m depth. Below about 3.5m depth (BH1) and 3.2m depth (BH2) the sands improved to medium dense and extended to the respective DCP test termination depths at 4.4m and 3.5m. Assuming a similar subsurface profile, the results of DCP101 and DCP102 have been interpreted to indicate very loose silty sands from below the fill (DCP101) and from surface level (DCP102). Below about 1.4m depth the relative density improved to loose, then medium dense below depths of about 2.5m (DCP101) and 2.1m (DCP102) to the termination depth of the DCP tests at 8m. Groundwater No groundwater was noted during or on completion of auger drilling the boreholes during the ASI investigation and in our current investigation, the DCP rods were ‘dry’ immediately after extraction. 4.3 Summary of Observations The summary of observations which follow in Sections 4.3.1 to 4.3.4 are to be read in conjunction with the attached Figure 2. 32032URrpt 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
geotech report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.