Appendix D - Table 9.4.5.3 Landscaping Code · OPW16/0303.02
Performance outcomes Acceptable Outcomes
Services, utilities and infrastructure PO12 achieved – refer to landscape plans
PO12 AO12.1
Vegetation does not pose a risk to the safety Vegetation planted within the easement of
or reliability of services, utilities or an overhead powerline or, where there is no
infrastructure including substations, easement, the area of influence of a
overhead powerlines, power poles and powerline, has a mature height of no more
transformers, street lamps, stormwater than 3.5 metres.
catchment pits, and underground services
and utilities. AO12.2
Vegetation planted within an underground
powerline easement does not have a mature
root system in excess of 150 millimetres in
depth and is not located directly over the
powerline.
AO12.3
Regardless of the width of the
easement, vegetation adjoining easements
must be separated from the power pole or
other infrastructure by a distance at least
equal to the maximum mature height of
the vegetation.
AO12.4
See the original