SUNSHINE BEACH HOUSE
46 & 48 SEAVIEW TERRACE
FOR
PAT RAFTER
GENERAL NOTES
Water Supply and Sanitary Drainage has been designed and shall be constructed in
accordance with the Q’ld Standard Sewerage Law, Q'Ild Standard Water Supply Law,
the National Plumbing and Drainage Code AS 3500., all relevant Australian Standards,
and the requirements of the Local Authority.
These Drawings are diagrammatic only and shall be read in conjunction with all relevant
Architectural and other consultants drawings and specifications and other written
instructions that may be issued during the course of the contract.
Any discrepancies shall be referred to the supervising officer for decision before
proceeding with the work.
Contractor shall verify all fixture locations, invert levels, surface levels, and
cover to pipes are correct and obtainable prior to commencement of the work.
The exact location of existing, and proposed services, shall be verified with
the relevant Authority, or other trades as applicable.
Fire stop collars to be used on all plastic pipework penetrating fire resistant
construction.
SANITARY DRAINAGE
Underground pipework shall be 100 dia. PVC DWV, min grade 1:60 U.N.O.
Suspended Pipework shall be PVC class DWV.
Trade waste pipework to grease trap suspended shall be “Coesprene” or
HDPE. Underground shall be vitreous clay or HDPE.
Trade waste pipework to oil separator shall be HDPE, or Vitreous clay with
"Nitrile” rubber rings.
CLeanouts or inspection openings brought to surface in paved or concrete
areas, or within buildings to have brass caps.
STORMWATER DRAINAGE
Underground pipework shall be 100 dia PVC class SW min grade 1:100 U.N.O.
Downpipes shall be 100 Dia PVC class SW.
Rainwater outlets (RWO) and planter outlets (PO) shall be "Gatic Wade” or similar,
with membrane clamp where required.
WATER SUPPLY
Pipework shall be copper tube type B. UNO. Water supply pipework shall be 20 dia
U.N.O, Except one fitting only may be 15 dia. max. length 3000 mm.
Hot water pipework shall lagged.
Hot water recirculating lines to be insulated with 20mm "Armaflex” or similar.
Provide tempering valves on hot water to personal hygiene fixtures.
Underground copper pipework shall be "Kemlagged” or otherwise protected.
Underground pipework not under concrete slab may be polypipe class PN20.
one size larger than shown.
Exposed pipework in amenities areas, shall be chrome plated.
Where water meters are installed within tennancies, provide remote readout
adjacent to Electrical meters, or in a position as indicated by the Architect.
BACKFLOW PREVENTION
Provide hose connection vacuum breakers to all hose cocks
Provide RPZD to any irrigation connections.
COVERS & FRAMES
Covers subject to vehicular traffic to be 535 dia, cast iron, medium duty UNO.
Covers in grassed or conc. areas to be 535 dia. cast iron, concrete infill light duty.
Covers in paved areas to be 600 sq. Infill to match paving pattern
Covers in tiled areas to be as for paved areas with brass edging.
Concrete infill covers to be stamped “SWD" or “SEW” as appropriate.
Covers & Frames to be "Faston” or equal approved.
GRATINGS
Gratings for storm water to be "faston, Gatic” or approved equal.
Duty to match manufacturers recommendations for loading condition
Trench grate to be transverse bar.
Floor waste grates to be chrome plated brass
LEGEND
Existing water Q Diameter
Existing sewer ¢.0.s. Cleanout to surface
Existing storm water CJ Capped junction
Existing house drain Cv Conrol valve
Sanitary Drainage cs Cleaners sink
Vent Pipe cw Cold Water
Cold Water DAP Duct access panel
Hoek. water ocv Double check valve
. Een Eccentric Enlarger
———— __ Storm Water Drainage Elev Dge Evevated Drainage
Fire En! Enlarger
agi Agi Drain FC False ceiling
FH Fire Hydrant
i FHR Fire hose reel
ie —— oo Finished floor level
Down Pipe FU Fixture units
Stack GIT Grease Interceptor trap
|
Z GP Gully pit
(3) © Vent Pipe GMH Gully Man Hole
@= Vv Gate valve
@) oye vent Aw Hot water
Educt vent HCB House connection branch
© HD House drain
® eet. HL High level
(=) © Hot water riser Ic Inspection Chamber
(By) o-——-Fire-Dropper—™ —— ae ao ,
: : io nspection openin
Fire Riser ios iaesecton ceening to Surface
K&C Kerb & Channel
—--(Mp-- water meter MH Manhole
NRV Non return valve
eS Vv Valve oy Path box
Bi kK Pressure limiting valve
LSA ccamahies PO Planter outlet
—sS—_ een Eccentric enlarger RPB Real Property Boundary
RPD Real Property description
----— en Enlarger RPZD Reduce Pressure Zone device
RWO Rain water outlet
e) ORG Overflow Relief Gully RWH Rain water head
SD Sanitary Drainage
[lo we Water SL Surface Level
Closet S Square
. aft Safe Tray
sk Sink swD Storm water drain
t/td Trapped Tundish
EY. Laundry tub TG Test gate
i td Tundish
(Sj wm Washing TG 9 Trench grate transverse bar
Machine TG Trench grate longitudinal bar
} FWG Floor Waste T.M.V. Thermostatic mixing valve
gully = Tempering valve
Basin u/g Underground
S - ° u/s Under slab
u.n.o. Unless noted otherwise
‘ee Bth Bath Ws Water supply
et FHR Fire Hose Reel b< Shr Shower
HWS Hot water system
cs Cleaners Sk C)
tet ke
7 ae
Awnaie ©
Tempering valve
Irrigation
Dishwasher
stormwater
system
STORMWATER HARVESTING STRATEGY
Roof water
[e
1 typical float valve
operated top up
rainwater tank in
Rainwater
zone
a
town main
storage zone
sludge zone
Stormwater
pit
Capilary bleed tubing
discharge point from
first flush device, or
in garden 1m away
\Zinstallation_on top.of_|.
Coral
Proposed
Development
Rainhead with leaf
screen and mosquito
screen if applicable
|
first | flush device
ee
visud| water
level site tube
optional
floating ball
valve
water
meter
Sludge valve
optional Ly} —-— oH - —-
Si ide eo re cs da ‘iin sp samen eel a
Max SOOkPa pressure
limiting valve within
path box
Sa ace ean er eh eg oe dere greta
RPB Towns
main
tors 991 & 60 on RPS1S10
DRAWINGS
1658 =e
1658-1 aa
1655-2 7
GENERAL NOTES
, Note:
All kitchen, laundry & bathroom fitti
& LEGEND
GROUND STORMWATER DRAINAGE
GROUND SANITARY DRAINAGE
ngs and toilets
to comply with the AAA Water Conservation Rating
System as defined by AS/NZS6400.
Provide flow restrictor valves where
to taps and shower roses. The flow
exceed a maximum of 9L/min
necessary
shall not
STANGES-.MAay T
DERARTED FROM
S$ APPROVED _
CATCHMENT AREAS
Pollution Control Management Plan (PCMP):
1
2.
s
4.
To be responsibility of Management
To list all in flow filtering devices like leaf eaters
at DP’s and other filters
To keep and maintain a log of cleaning
To clean devices including first flush storage tank
—as to manufactures specification
—minimum quarterly, but monthly in rainy season
—after each major rainfall event
To inspect and clean tanks minimum once yearly
To install and maintain pump and fixtures for
reuse/watering/irrigation as to manufactures specification
IAs Constructed —
FIOVAL of the MANAGER LAND DEVE
Description
Notes
Date 4
27-10-06
For Construction
Building Service Engineers
&
Construction Hydraulic
PO Box 1176
Buddina QLD 4575
email: [email protected]
www.conhyd.com
contact: Reinhold Koenning MicAust RPEQ No 7023
PH: 5444 8645
FX: 5444 8224
CLIENT :
PATRICK RAFTER
ARCHITECT :
JOHN BURGESS ARCHITECTS
PROJECT:
46 & 48 SEAVIEW TERRACE
SUNSHINE BEACH HOUSE
DRAWING TITLE:
GENERAL NOTES &
LEGEND
Date |13—12—06 | Dwg. No.
ON Al U.N.O.
RPD:— Lots 59 & 60 on RP81810
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0174 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.