U11 Pavilion
GENERAL
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. IF IN DOUBT, ASK.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,
SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERING
MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
CONFORM TO THE NATIONAL CONSTRUCTION CODE OF AUSTRALIA, CURRENT
AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN PLANNING
REQUIREMENTS, REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF
AUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION
AS 1562 - 2006 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE
AS 2049 - 2002 ROOF TILES
AS 2050 - 2002 INSTALLATION OF ROOF TILES
AS 2870 - 2011 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION
AS/NZS 2904 - 1998 DAMP-PROOF COURSES AND FLASHINGS
AS 3600 - 2010 CONCRETE STRUCTURES
AS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES
AS 3700 - 2011 MASONRY IN BUILDINGS
AS 3740 - 2010 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS
UNIT 1
AS 3786 - 2004 SMOKE ALARMS
AS 4055 - 2012 WIND LOADINGS FOR HOUSING 1
AS 4100 - 2012 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY SOIL, STRUCTURAL AND
CIVIL ENGINEERING COMPUTIONS AND DRAWINGS.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE
WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX
INDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -
i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR N
ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE
UNIT 1
iii) FULLY GLAZED DOORS
iv) SHOWER SCREENS 1
v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
WITH MANUFACTURER, AND ARE TO BE VERIFIED WITH SAME. FLASHING ALL ROUND.
STORMWATER TO BE TAKEN TO ON SITE STORAGE OF PROVIDED, THEN THE LEGAL
POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVER THE
FLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF
PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF
1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL
CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS ARE TO BE WHOLLY WITHIN TITLE BOUNDARIES AND ARE NOT TO ENCROACH
EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN
CLOSE PROXIMITY OF BOUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED
SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
UNIT 1
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL
BE IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 1
75mm OF THE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND
Replace U8 Ensuite
WITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL. Window
SUB-FLOOR VENTILATION MINIMUM 7500mm/sq FOR EXTERNAL WALLS AND
1500mm/sq FOR INTERNAL WALLS BELOW BEARER.
THERMAL INSULATION TO BE PROVIDED TO ACHIEVE MINIMUM REQUIREMENTS AS
SPECIFIED BY LICENSED ASSESSOR.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,
SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.
BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND
IN ACCORDANCE WITH BCA 3.9.2
FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE
CONSTRUCTION - REQUIRED WIRE TENSION AND MAXIMUM PERMISSIBLE
DEFLECTION) OF THE BCA.
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF
EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans),
TO BE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.
PROVIDE LIFT OFF HINGES, OPEN OUT DOOR OR MIN 1200mm CLEARANCE FROM DOOR
TO PAN IN WATER CLOSETS.
EXHAUST FANS FROM SANITARY COMPARTMENTS ARE TO BE DUCTED EXTERNALLY
OR TO A VENTED ROOF SPACE IN COMPLIANCE WITH AS 1668.2
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS,
STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS.
SURVEYOR TO CONFIRM SETOUT PRIOR TO COMMENCEMENT OF WORKS.
LA MER NOOSA
37 HASTINGS STREET
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THE
SITE PLAN NOOSA HEADS
Construction
AUTHOR.
SCALE : 1 : 250
Lot 8 & 11 BUP8083
Property Id: 131324
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Site Plan SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A001
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: As indicatedSHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 11 pages
Page 2
WALL LEGEND - DEMO
EXISTING WALL
DEMOLISHED WALL
9700 2975 2975 2695 560 3400
Ens
1760
TILES
d/w
Bed 3
2550
CH 2560
100mm
Kitchen Bed 2 100mm
4010
CARPET Bed 1
robe
Ocean Living Dining Street
4970
CH 2560
spa
1480
CH 2325
CH 2320 ref service
Terrace robe CARPET CH 2560 TILES CH 2560
Terrace
600
duct
CH 2515
Bath
6330
CARPET
robe service
VINYL duct linen
PLANKS
L'dry
TILES
860
line of stairs above linen VINYL
PLANKS
1445
store CH 2515 CH 2560
step in concrete slab (ceiling)
EXISTING APARTMENT FLOOR PLAN
SCALE : 1 : 100
N
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Paul Kostromin and Annette Fraser
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Existing Apartment Floor Plan SITE ADDRESS: 8 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and May 2021 DRAWING No:
A101
ISSUE: D DATE: 15/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
U8
Page 3
WALL LEGEND - PROPOSED
NOTE:
EXISTING WALL Soundproofing to new kitchen / laundry bulkhead:
provide 2 layers of 13mm Gyprock Soundchek plasterboard, stagger joints
provide accoustic batts at pipework
PROPOSED WALL Bradfords SoundScreen™ R2.0 for walls, floors & ceilings
NOTE:
Refer to drawings by Gull Design for all cabinery and room setouts
new window with offset center mullion
to suit wall location
frame and colour to match existing window
9700 2975 2975 2695
1195 90 1430
2850 1330 90 1275
bunkette seating
1730
m/w
Bed 3 Bed 1
robe
Dining CH 2500 CH 2500
100mm
CH 2500 Bed 2 CH 2500
100mm
TILES Ens 1 TILES
sink TILES
Ens 2
Ocean
ref CH 2500
Street
4970
H/W
1610
CH 2320
Living S
770 D
CH 2325
Terrace d/w
Kitchen robe service TILES Terrace
TILES CH 2450 duct
6330
CH 2400 TILES
robe
TILES S
tub Pdr service
robe
L'dry
line of stairs above S linen duct linen TV
CH 2400
w/m
CH 2400 TILES
S S
770 D
dryer
S
Entry
TILES
CH 2450 CH 2500
515 1520 560
new opening for door
c'brd seat TV shelves refer to Structural
Engineering drawings
new steel post
refer to Structural Engineering drawings step in concrete slab (ceiling) provide step up
into shower recess
to accommodate plumbing
line of dropped ceiling over
PROPOSED APARTMENT FLOOR PLAN
SCALE : 1 : 100
N
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Paul Kostromin and Annette Fraser
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Proposed Apartment Floor Plan SITE ADDRESS: 8 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and May 2021 DRAWING No:
A111
ISSUE: D DATE: 15/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
U8
Page 4
WALL LEGEND - DEMO
EXISTING WALL
DEMOLISHED WALL
3540 1480
Roof Top Terrace
3845
3845
Pergola
11.46m2
1190
DOWN
2575
1385
UPDOW N
EXISTING ROOF TOP TERRACE PLAN
SCALE : 1 : 100
N
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Existing Roof Top Terrace Plan SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A102
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 5
WALL LEGEND - PROPOSED
EXISTING WALL
PROPOSED WALL
Roof Top Terrace Pergola New Cabinetry
renew tiles new shape bench
renew skirting tiles Accoya Timber sink
renew drain cover new treatment to ceiling cupboard
new screen to South East wall (block a/c units on neighbor roofs) new Accoya timber posts and beams fridge
roof over
refer to 1:20 drawings
(note portable BBQ)
10201
5501 3540 1480
2905
1000
900
outdoor shower
new cabinerty
3845
3845
d/w
2845
Roof Top hot and cold water
4135
Terrace
ref
Pergola
11.46m2
1190
1190
DOWN
2575
1385
DOW N
PROPOSED ROOF TOP TERRACE PLAN
SCALE : 1 : 100
N
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Proposed Roof Top Terrace Plan SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A112
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 6
remove existing pergola
replace existing U8 ensuite window
EAST ELEVATION - EXISTING
SCALE : 1 : 100
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all East Elevation - Existing SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A201
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 7
re-new pergola
move towards the South
new outdoor shower
new cabinetry
re-new window
same external frame & size
2 x awning windows
increase one awning
decease second awning
EAST ELEVATION - PROPOSED
SCALE : 1 : 100
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all East Elevation - Proposed SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A202
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 8
pergola beams - painted white
1.2m solid wall behind
painted and rendered
to match existing walls Makrolon clear sheeting
Accoya timber screen over over
38 x 38mm (no gaps)
existing roof
new pergola
Covered area 11.46m2
existing pergola
to be removed pergola beams -
Covered area 11.46m2 light coloured hdwd timber
Accoya Timber
100 x 100 hdwd timber posts
light colour
Accoya Timber
round timber ceiling lining
CEILING LINING
Makrolon sheeting
pergola beams - over
light coloured hdwd timber 2880
Accoya Timber
100 x 100 hdwd timber posts
light timber colour
Accoya Timber
38 x 38mm Accoya battens Accoya screen
15mm gaps 38 x 38mm no gaps
2708
2636
2450
2400
new cabintery
1.2m solid wall behind
painted and rendered
to match existing walls
screen over
NEW PERGOLA SECTION A-A
NORTH ELEVATION - EXISTING NORTH ELEVATION - PROPOSED 1 : 100 SCALE :
SCALE : 1 : 100 SCALE : 1 : 100
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all North Elevations & Pergola Section SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A203
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 9
3D EAST VIEW -
EXISTING
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all 3D East View - Existing SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A210
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 10
3D EAST VIEW -
PROPOSED
PERGOLA
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all 3D East View - Proposed SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A211
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 11
3D NORTH VIEW - 3D NORTH VIEW -
EXISTING PROPOSED
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all 3D North Views SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
A212
ISSUE: L DATE: 16/07/2021 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Page 12
WHS REPORT
The following notes make up the recommended minimum report required under the Work Health and Safety Act 2011. Under the Act designers are required to
“provide adequate information to each person who is provided with the design” and also to “any person who carries out activities in relation to the structure if
requested”. (Draft Code of Practice: Safe Design of Building and Structures)
Specifically, the designer is required to provide “the person commissioning the design on the health and safety aspects of the design”. (Draft Code of Practice: Safe 5. MANUAL TASKS
Design of Building and Structures) Components within this design with a mass in excess of 25kg should be lifted by two or more workers or by mechanical lifting device. Where this is not practical,
These notes have been prepared based on the Draft Code of Practice: Managing Risks in Construction Work and discussing the risks which the Code identifies as suppliers or fabricators should be required to limit the component mass.
common in the construction of buildings. It follows that most are also the risks associated with maintenance and demolition. All material packaging, building and maintenance components should clearly show the total mass of packages and where practical all items should be stored on site
If the building has been designed as a workplace and the end-use is known at the time of design, additional operational health and safety issues must be identified in a way which minimises bending before lifting. Advice should be provided on safe lifting methods in all areas where lifting may occur.
and addressed by the designer through consultation with clients, workers and/or other safety consultants. Notes on operational issues must be added to the report. Construction, maintenance and demolition of this building will require the use of portable tools and equipment. These should be fully maintained in accordance with
To ensure that all relevant persons are made aware of the report provisions, it is recommended that the report be part of the drawings but the “person manufacturer’s specifications and not used where faulty or (in the case of electrical equipment) not carrying a current electrical safety tag. All safety guards or
commissioning the design” should also be made aware that the report applies not only to the construction stage but also to maintenance, renovation, demolition devices should be regularly checked and Personal Protective Equipment should be used in accordance with manufacturer’s specification.
and, if applicable, to the operation of the building as a workplace. It should be retained and displayed or kept in a prominent location during the operation of the
building. 6. HAZARDOUS SUBSTANCES
ASBESTOS
(for alterations to a building constructed prior to 1990)
1. FALLS, SLIPS, TRIPS This building was constructed prior to 1990 and therefore may contain asbestos either in cladding material or in fire retardant insulation material. The builder
a) WORKING AT HEIGHTS should check and, if necessary, take appropriate action before demolishing, cutting, sanding, drilling or otherwise disturbing the existing structure.
DURING CONSTRUCTION (for alterations to a building constructed prior to 1986)
Wherever possible, components for this building should be prefabricated off-site or at ground level to minimise the risk of workers falling more than two metres. This building was constructed prior to 1986 and therefore is likely to contain asbestos either in cladding material or in fire retardant insulation material. The builder
However, construction of this building will require workers to be working at heights where a fall in excess of two metres is possible and injury is likely to result from should check and, if necessary, take appropriate action before demolishing, cutting, sanding, drilling or otherwise disturbing the existing structure.
such a fall. The builder should provide a suitable barrier wherever a person is required to work in a situation where falling more than two metres is a possibility. POWDERED MATERIALS
DURING OPERATION OR MAINTENANCE Many materials used in the construction of this building can cause harm if inhaled in powdered form. Persons working on or in the building during construction,
(for houses or other low-rise buildings where scaffolding is appropriate) operational maintenance or demolition should ensure good ventilation and wear Personal Protective Equipment including protection against inhalation while using
Cleaning and maintenance of windows, walls, roof or other components of this building will require persons to be situated where a fall from a height in excess of two powdered material or when sanding, drilling, cutting or otherwise disturbing or creating powdered material.
metres is possible. Where this type of activity is required, scaffolding, ladders or trestles should be used in accordance with relevant codes of practice, regulations or TREATED TIMBER
legislation. The design of this building includes provision for the inclusion of treated timber within the structure. Dust or fumes from this material can be harmful. Persons
(for buildings where scaffold, ladders, trestles are not appropriate) working on or in the building during construction, operational maintenance or demolition should ensure good ventilation and wear Personal Protective Equipment
Cleaning and maintenance of windows, walls, roof or other components of this building will require persons to be situated where a fall from a height in excess of two including protection against inhalation of harmful material when sanding, drilling, cutting or using treated timber in any way that may cause harmful material to be
metres is possible. Where this type of activity is required, scaffolding, fall barriers or Personal Protective Equipment should be used in accordance with relevant released. Do not burn treated timber.
codes of practice, regulations or legislation. VOLATILE ORGANIC COMPOUNDS
(if appropriate, add this note) Many types of glue, solvents, spray packs, paints, varnishes and some cleaning materials and disinfectants have dangerous emissions. Areas where these are used
Anchorage points for portable scaffold or fall arrest devices have been included in the design for use by maintenance workers. Any persons engaged to work on the should be kept well ventilated while the material is being used and for a period after installation. Personal Protective Equipment may also be required. The
building after completion of construction work should be informed about the anchorage points. manufacturer’s recommendations for use must be carefully considered at all times.
b) SLIPPERY OR UNEVEN SURFACES SYNTHETIC MINERAL FIBRE
FLOOR FINISHES Fibreglass, rockwool, ceramic and other material used for thermal or sound insulation may contain synthetic mineral fibre which may be harmful if inhaled or if it
The owner is responsible for the selection of surface finishes in the pedestrian trafficable areas of this building. Surfaces should be selected in accordance with AS comes in contact with the skin, eyes or other sensitive parts or the body. Personal Protective Equipment including protection against inhalation of harmful material
HB 197:1999 and AS/NZ 4586:2004. should be used when installing, removing or working near bulk insulation material.
STEPS, LOOSE OBJECTS AND UNEVEN SURFACES TIMBER FLOORS
Due to design restrictions for this building, steps and/or ramps are included in the building which may be a hazard to workers carrying objects or otherwise This building contains timber floors which have an applied finish. Areas where finishes are applied should be kept well ventilated during sanding and application and
occupied. Steps should be clearly marked with both visual and tactile warning during construction, maintenance, demolition and at all times when the building for a period after installation. Personal Protective Equipment may also be required. The manufacturer’s recommendations for use must be carefully considered at all
operates as a workplace. times.
Building owners and occupiers should monitor the pedestrian access ways and in particular access to areas where maintenance is routinely carried out to ensure
that surfaces have not moved or cracked so that they become uneven and present a trip hazard. Spills, loose material, stray objects or any other matter that may
cause a slip or trip hazard should be cleaned or removed from access ways. 7. CONFINED SPACES
Contractors should be required to maintain a tidy work site during construction, maintenance or demolition to reduce the risk of trips and falls in the workplace. EXCAVATION
Materials for construction or maintenance should be stored in designated areas away from access ways and work areas. Construction of this building and some maintenance on the building will require excavation and installation of items within excavations. Where practical, installation
should be carried out using methods which do not require workers to enter the excavation. Where this is not practical, adequate support for the excavated area
2. FALLING OBJECTS should be provided to prevent collapse. Warning signs and barriers to prevent accidental or unauthorised access to all excavations should be provided.
LOOSE MATERIALS OR SMALL OBJECTS ENCLOSED SPACES
Construction, maintenance or demolition work on or around this building is likely to involve persons working above ground level or above floor levels. Where this Enclosed spaces within this building may present a risk to persons entering for construction, maintenance or any other purpose. The design documentation calls for
occurs one or more of the following measures should be taken to avoid objects falling from the area where the work is being carried out onto persons below. warning signs and barriers to unauthorised access. These should be maintained throughout the life of the building. Where workers are required to enter enclosed
1. Prevent or restrict access to areas below where the work is being carried out. spaces, air testing equipment and Personal Protective Equipment should be provided.
2. Provide toeboards to scaffolding or work platforms. SMALL SPACES
3. Provide protective structure below the work area. Some small spaces within this building will require access by construction or maintenance workers. The design documentation calls for warning signs and barriers
4. Ensure that all persons below the work area have Personal Protective Equipment. to unauthorised access. These should be maintained throughout the life of the building. Where workers are required to enter small spaces they should be
BUILDING COMPONENTS scheduled so that access is for short periods. Manual lifting and other manual activity should be restricted in small spaces.
During construction, renovation or demolition of this building, parts of the structure including fabricated steelwork, heavy panels and many other components will
remain standing prior to or after supporting parts are in place. Contractors should ensure that temporary bracing or other required support is in place at all times 8. PUBLIC ACCESS
when collapse which may injure persons in the area is a possibility. Public access to construction and demolition sites and to areas under maintenance causes risk to workers and public. Warning signs and secure barriers to
Mechanical lifting of materials and components during construction, maintenance or demolition presents a risk of falling objects. Contractors should ensure that unauthorised access should be provided. Where electrical installations, excavations, plant or loose materials are present they should be secured when not fully
appropriate lifting devices are used, that loads are properly secured and that access to areas below the load is prevented or restricted. supervised.
9. OPERATIONAL USE OF BUILDING
3. TRAFFIC MANAGEMENT This building has been designed as a residential building. If it, at a later date, is used or intended to be used as a workplace, the provisions of the Work Health and
Parking of vehicles or loading/unloading of vehicles on this roadway may cause a traffic hazard. During construction, maintenance or demolition of this building Safety Act 2011 or subsequent replacement Act should be applied to the new use.
designated parking for workers and loading areas should be provided. Trained traffic management personnel should be responsible for the supervision of these This building has been designed for the specific use as identified on the drawings. Where a change of use occurs at a later date a further assessment of the
areas. workplace health and safety issues should be undertaken.
Construction of this building will require loading and unloading of materials on the roadway. Deliveries should be well planned to avoid congestion of loading areas
and trained traffic management personnel should be used to supervise loading/unloading areas. 10. OTHER HIGH RISK ACTIVITY
Busy construction and demolition sites present a risk of collision where deliveries and other traffic are moving within the site. A traffic management plan supervised All electrical work should be carried out in accordance with Code of Practice: Managing Electrical Risks at the Workplace, AS/NZ 3012 and all licensing
by trained traffic management personnel should be adopted for the work site. requirements.
All work using Plant should be carried out in accordance with Code of Practice: Managing Risks of Plant at the Workplace.
4. SERVICES All work should be carried out in accordance with Code of Practice: Managing Noise and Preventing Hearing Loss at Work.
Rupture of services during excavation or other activity creates a variety of risks including release of hazardous material. Existing services are located on or around Due to the history of serious incidents it is recommended that particular care be exercised when undertaking work involving steel construction and concrete
this site. Where known, these are identified on the plans but the exact location and extent of services may vary from that indicated. Services should be located using placement. All the above applies.
an appropriate service (such as Dial Before You Dig), appropriate excavation practice should be used and, where necessary, specialist contractors should be used.
If underground power lines are located in or around this site. All underground power lines must be disconnected or carefully located and adequate warning signs
used prior to any construction, maintenance or demolition commencing.
If overhead power lines are near or on this site. These pose a risk of electrocution if struck or approached by lifting devices or other plant and persons working
above ground level. Where there is a danger of this occurring, power lines should be, where practical, disconnected or relocated. Where this is not practical
adequate warning in the form of bright coloured tape or signage should be used or a protective barrier provided.
Construction
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Annie and Andrew Bell
Use written dimensions only. DO NOT scale drawings. Contractors to verify all WHS Report Notes SITE ADDRESS: 11 La Mer Apartments
dimensions and levels on site prior to commencing works and shop drawings. 37 Hastings Street, Noosa Heads
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2021 DRAWING No:
WHS1
LISSUE: 16/07/2021
DATE: DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 100 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.