                                                                                                                                                                                                                                                                            Move and Replace
                                                                                                                                                                                                                                                                            U11 Pavilion
     GENERAL
     DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. IF IN DOUBT, ASK.
     THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,
     SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERING
     MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
     CONFORM TO THE NATIONAL CONSTRUCTION CODE OF AUSTRALIA, CURRENT
     AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN PLANNING
     REQUIREMENTS, REPORT ANY DISCREPANCIES TO THIS OFFICE.
     ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF
     AUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
     AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION
     AS 1562 - 2006 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
     AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE
     AS 2049 - 2002 ROOF TILES
     AS 2050 - 2002 INSTALLATION OF ROOF TILES
     AS 2870 - 2011 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION
     AS/NZS 2904 - 1998 DAMP-PROOF COURSES AND FLASHINGS
     AS 3600 - 2010 CONCRETE STRUCTURES
     AS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES
     AS 3700 - 2011 MASONRY IN BUILDINGS
     AS 3740 - 2010 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS
                                                                                                                                                                                                                                                   UNIT 1
     AS 3786 - 2004 SMOKE ALARMS
     AS 4055 - 2012 WIND LOADINGS FOR HOUSING                                                                                                                                                                                                            1
     AS 4100 - 2012 STEEL STRUCTURES
     THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY SOIL, STRUCTURAL AND
     CIVIL ENGINEERING COMPUTIONS AND DRAWINGS.
     ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE
     WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX
     INDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.

     SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -
     i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR                                                                                N
     ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE
                                                                                                                                                                                                                                             UNIT 1
     iii) FULLY GLAZED DOORS
     iv) SHOWER SCREENS                                                                                                                                                                                                                            1
     v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
     vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
     WITH MANUFACTURER, AND ARE TO BE VERIFIED WITH SAME. FLASHING ALL ROUND.
     STORMWATER TO BE TAKEN TO ON SITE STORAGE OF PROVIDED, THEN THE LEGAL
     POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY.
     TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVER THE
     FLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF
     PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF
     1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL
     CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
     FOOTINGS ARE TO BE WHOLLY WITHIN TITLE BOUNDARIES AND ARE NOT TO ENCROACH
     EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN
     CLOSE PROXIMITY OF BOUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED
     SURVEYOR.
     ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
                                                                                                                                                                                                                                      UNIT 1
     ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL
     BE IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN                                                                                                                                                                    1
     75mm OF THE WALL.
     PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND
                                                                                                                                                                                                                                                                                Replace U8 Ensuite
     WITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.                                                                                                                                                                                                     Window
     SUB-FLOOR VENTILATION MINIMUM 7500mm/sq FOR EXTERNAL WALLS AND
     1500mm/sq FOR INTERNAL WALLS BELOW BEARER.

     THERMAL INSULATION TO BE PROVIDED TO ACHIEVE MINIMUM REQUIREMENTS AS
     SPECIFIED BY LICENSED ASSESSOR.
     STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,
     SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.
     BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND
     IN ACCORDANCE WITH BCA 3.9.2
     FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE
     CONSTRUCTION - REQUIRED WIRE TENSION AND MAXIMUM PERMISSIBLE
     DEFLECTION) OF THE BCA.
     THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF
     EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
     DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans),
     TO BE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.
     PROVIDE LIFT OFF HINGES, OPEN OUT DOOR OR MIN 1200mm CLEARANCE FROM DOOR
     TO PAN IN WATER CLOSETS.
     EXHAUST FANS FROM SANITARY COMPARTMENTS ARE TO BE DUCTED EXTERNALLY
     OR TO A VENTED ROOF SPACE IN COMPLIANCE WITH AS 1668.2
     THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS,
     STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS.

     SURVEYOR TO CONFIRM SETOUT PRIOR TO COMMENCEMENT OF WORKS.
                                                                                                                                                                                                           LA MER NOOSA
                                                                                                                                                                                                        37 HASTINGS STREET
     THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THE
                                                                                                                                                     SITE PLAN                                             NOOSA HEADS
                                                                                                                                                                                                                                                      Construction
     AUTHOR.
                                                                                                                                                    SCALE : 1 : 250
                                                                                                                                                                                                         Lot 8 & 11 BUP8083
                                                                                                                                                                                                            Property Id: 131324
                                                                                                                                                                  DRAWING TITLE:
                                                                                  GENERAL NOTES:                                                                                                                                  CLIENT NAME:    Annie and Andrew Bell
                                                                                  Use written dimensions only. DO NOT scale drawings. Contractors to verify all    Site Plan                                                      SITE ADDRESS:   11 La Mer Apartments
                                                                                  dimensions and levels on site prior to commencing works and shop drawings.                                                                                      37 Hastings Street, Noosa Heads
                                                                                  Site location is Category N3 or to engineer's requirements.
                                                                                  These drawings are to be read in conjunction with engineer's design and                                                                                  Feb 2021                                   DRAWING No:

                                                                                                                                                                                                                                                                                             A001
                                                                                                                                                                  ISSUE: L         DATE:   16/07/2021                             DATE:
                                                                                  details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419                                                                                                                                                                                 SCALE:    As indicatedSHEET SIZE: A3
                                                                                  If in doubt, please request clarification. DO NOT ASSUME.
Log in to download the original file

Plans Unit 8 & 11.pdf · 1.9 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.