Council archive · source document
Approved Plans - MCU22/0140
Plans and drawings: the text below has words only, no drawings.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
WINDOW SCHEDU... WINDOW SCHEDU... LEGEND - INTERNAL
6000 2040 465 2040 6000 BC - BROOM CUPBOARD
-
NO. SIZE NO. SIZE
APPROVED PLAN
C'BD - CUPBOARD
DP - DOWNPIPE
W30 SD2129-4 W38 1806DH 70 5860 70 4545 70 5860 70 DW - DISHWASHER PROV.
W31 1215SW W39 2124PLD MCU22/0140 FW - FLOOR WASTE
HP - HOT PLATE
W32 1215SW W40 2124PLD 60070 7470 265 7470 70 600 NOOSA COUNCIL HWS - HOT WATER SYSTEM
L - LINEN
W33 SD2129-4 W41 1806DH
70 70 530 70 1730 14 DECEMBER 2022 MH - MANHOLE
W34 0618SW W42 1806DH 2935 70 2665 1730 70 530 70 2665 70 2935 70 MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
W35 0612SW W43 1815SW 70 70 70 PTY - PANTRY
W36 1815SW W44 0612SW 70 1000 70 1865 70 775 70 1130 690 530 1730 265 1730 70 530 690 1130 70 775 70 1865 70 1000 70 R - ROBE
REF - REFRIDGERATOR SPACE
W37 1806DH W45 0618SW RH - RANGEHOOD
UNIT 3
UNIT 4
SH - SHELF
2590 2900 510 285 1500 255465255 1500 285 519 2900 2590 TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
WO - WALL OVEN
A
LEGEND - EXTERNAL
18 BV - BRICK VENEER
CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
HWS A/C UNIT RBB - RENDERED BLUEBOARD
DP W30
100
RB - RENDERED BRICKWORK
DP
600
HWS
70
TAP
515
A/C UNIT RBL - RENDERED BLOCKWORK
70 700
A/C POSTION
DP W33 DP
SA - SCYON AXON
W31
70
515
TAP SL - SCYON LINEA
70 700
W32 A/C POSTION SM - SCYON MATRIX PANELING
B/BAR
SS - SCYON STRIA CLADDING
2775
2635
1800
W45
WB - HARDIES NEWPORT
LIVING MEALS
B/BAR
O/MW/OHC CT/RH
W34
2635
2775
1800
3750
3750
FLOOR AREAS
4200
MEALS LIVING
O/MW/OHC CT/RH
RA
3750
3750
3500
Unit 2 94.02 m²
460
K
4200
70 1045 70
ED
G
L IN
80
Unit 1 94.33 m²
3500
CE
460
I
CE
B
I
1045
Unit 3 100.07 m²
L IN
285 890
1045 70
820
80
DP
ED
G
18 Unit 1 - Porch 2.12 m²
K
PTY
PTY
1045
CEILING LINE
RA
75 890
820
75
1650 NICHE BR 820 C/S REF PROV. Unit 2 - Porch 2.43 m²
8440
REF PROV. CEILING LINE
90
90
70
620 Unit 4 103.27 m²
820 C/S BR
1210
W44
1650
1650
1650
1650 NICHE
285
8440
TRH WM PROV. Grand total 396.24 m²
STUDY
M/S 1.3
90
BTH 620
LINEN
TRH
1380
1380
W35
1210
1650
1650
1650
SKYLIGHT LND WM PROV. ISSUE
STUDY
BTH
M/S 1.3
LINEN
1000 TR 820
1380
# DATE DETAILS BY
820
70
LND
995
SKYLIGHT
70
TR - 23-07-21 CONCEPT ISS. DC
1000
70 530
70 940
820
70 940 70
STORE - 06-08-21 CONCEPT ISS. A JS
995
70
13330
- 10-09-21 NHP ISSUE AN
820
STORE A 27-09-21 WD ISSUE JB
820 C/S
SH V/S 2.9
BED 2
2900
2900
1500
W43
B 25-10-22 WD ISSUE DPC
820 C/S
V/S 2.8
M/S 1.7
SH
BED 2
1500
2900
2900
1890
W36
ROBE
M/S 1.7
1890
M/H 555x555
8560
ROBE
7660
M/H 555x555
70
820
NICHE
GARAGE
1000
70
820
5800
NICHE
DP
GARAGE
6400
ROBE
1480 po box 6384 p (07) 5319 1500
3670
1000
M/S 2.4
maroochydore f (07) 5450 6437
2540
ROBE
1480 qld 4558 QBCC 1083000
A/C POSTION
3670
M/S 2.4
TR
BED 1
2540
3630
3630
DP
E
A/C UNIT
TRH WRITTEN DIMENSIONS TO TAKE
A/C POSTION
TR
PRECEDENCE OVER SCALE
BED 1
3630
3630
3630
A/C UNIT
SH
N E TRH UNIT 3-4
1020 70
SH
820 C/S
S N
1020 70
900
820 C/S
METERBOX 2124PLD
S
170
750
70
900
2124PLD
150
500 350
TAP W42 W41 DP W40 DP METERBOX
70
170
TIMBER BACKING TO FASCIA REQUIRED W39 PROJECT DESCRIPTION:
DP W38 W37 TAP
TIMBER BACKING TO FASCIA REQUIRED PROPOSED DEVELOPMENT
350
CLIENT:
90 x 90 LAMINATED HWD POST 725 690 1310 690 2125 2400 200 665 2400 2170
R KILDEY
ON GALV. STIRRUP 600 1400 600 770 90 x 90 LAMINATED HWD POST
70 530 70 1730 70 70
70 3780 70 1820 265 1730 530 1820 70 3780 70 ON GALV. STIRRUP
70 SITE ADDRESS:
3235 70 475 1130 90 3000 3000 90 1130 530 3180
LOT 616 RUBY ST
90 70 70 90 See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU22/0140Related documentApplication case desk ↗
About this file
- File size
- 1.9 MB (small file)
- File type
No other editions are linked here.