LEGEND
FENCE, GATE, BOLLARD
O/H ELECTRICITY, LIGHT POLE, POWER POLE
U/G ELECTRICITY, PIT, BOX, MANHOLE
BITUMEN
CARPARK O/H COMMUNICATIONS, POLE
BITUMEN
CARPARK U/G COMMUNICATIONS, PIT, BOX, MANHOLE
KERB AND CHANNEL, SIGN, GULLY TRAP
GRAVEL DRIVEWAY SEWER PIPE, MANHOLE
STORM WATER PIPE, FIELD INLET, MANHOLE
WATER MAIN, VALVE, HYDRANT, METER
GAS MAIN, VALVE, METER
20 YED
SHED UNIDENTIFIED SERVICE, PIT, MANHOLE
)
INSPECTION OPENING, WITNESS MARKER
DRIVEWAY
21
DRIVEWAY
NE VE
TOP OF BANK
Y ED
BOTTOM OF BANK
)
)
NUARY 2017
NE 2021)
JU UR
17
SHOP TREE
TYPE GUM TREE, TRUNK DIAMETER 400mm
AR VEY
HEIGHT 15metres
GRAVEL
GRAVEL
(S
Other types: PM = Palm
20
(SURVEYED JU
NS = Not specified
(SURVEYED JA
NU R
JA (SU UNDERGROUND UTILITY QUALITY LEVELS
QUALITY LEVEL A: Highest quality level, positive
identification and absolute spatial position in three
dimensions (eg Direct measurement and visible)
QUALITY LEVEL B: Relative subsurface feature
location in three dimensions (eg Electronic trace)
QUALITY LEVEL C: Approximate location and
FIBRO attributes using a combination of existing records and
BUILDING a survey of visible evidence
QUALITY LEVEL D: Lowest quality level. Compiled
from any, or a combination of existing records, site
inspections, anecdotal evidence
NOTES
(4) Prior to any demolition, excavation or construction on the site,
SHED NOTES the classification and location of these services should be
confirmed and the relevant authority should be contacted for
RESIDENTIAL (1) This plan was prepared for the purpose and exclusive use of possible location of further underground services and detailed
DWELLING ALTUM PROPERTY GROUP and their other professional advisers
7/07/2021 S:\M2677\OLIVER - EUMUNDI RD\AUTOCAD\M2677-09A COMBINED DETAIL
locations of all services.
and is not to be used for any other purpose or by any other person
or corporation. (5) Spot heights and contours are representative of the
JFP URBAN CONSULTANTS PTY LTD accepts no responsibility for topographical terrain at time of survey; January 2017 & June 2021,
any loss or damage arising to any person or corporation who may as shown on plan.
use or rely on this plan in contravention of these terms.
(6) Spot heights are not shown on this plan. Refer to the AutoCAD
(2) The title boundaries shown on this plan were not marked at drawing for all spot heights and codes in frozen layers: X-RL,
the time of survey and have been determined from plan X-CODE & X-MARK.
dimensions only and not by field survey. The dimensions and
PROPERTY DESCRIPTION positioning of these property boundaries and any other (7) Trees shown on this plan have been located only where the
boundaries shown on this plan are not absolute and are subject to trunk diameter at breast height (DBH) is 300mm or greater. Tree
LOT 1 ON RP230931 an Identification Survey. Please contact this office for a quote or types are estimated and tree sizes are approximate only. If
TOTAL AREA 3740m² (Deed) for further advice. accurate identification of tree types is to be relied upon for any
LOT 1 ON RP849431 purpose, then all trees shown will require on site verification by a
(3) The Location of Underground services are in accordance with suitably qualified expert.
TOTAL AREA 1748m² (Deed) Australian Standard AS5488:2019, Classification of Subsurface
Utility Information (SUI). Services shown hereon have been (8) These notes form an integral part of this plan. If others use this
LOT 61 on RP69404 located where possible by field survey. If not able to be so located, information, they should be advised of its purpose and limitations.
TOTAL AREA 3184m² (Deed) services have been plotted from the records of the relevant
authorities where available. However, the information shown on (9) This plan may not be reproduced unless these notes are
LOCALITY OF NOOSAVILLE these records pertinent to services location is indicative only and included.
NOOSA SHIRE COUNCIL sometimes inadequate. The exact nature and location of these
services should be confirmed prior to construction. Contour Interval: 0.5m
NORTH: SCALE: ISSUES: TITLE: DETAILS:
JOB NUMBER: PLAN: ISSUE:
N SCALE: @ A3 1:500
BRISBANE - SUNSHINE COAST - CENTRAL QLD PLANNERS 0 5 10 15 20 25 30 35
CONTOUR & DETAIL SURVEY M2677
SHEET:
09 A
SCALE 1:500 at (A3) size
URBAN DESIGNERS
SUNSHINE COAST
Tower 1, Level 2, 55 Plaza Parade, SURVEYORS
THIS SCALE SHOWN IS ORIGINAL DRAWING SCALE - (A3 SIZE)
ALTUM PROPERTY GROUP 1 OF 1
DO NOT SCALE FROM THIS DRAWING - USE ONLY DIMENSIONS PROVIDED - IF IN DOUBT PLEASE ENQUIRE FILE:
Maroochydore, Qld 4558
P 07 5450 3900 W www.jfp.com.au ENGINEERS
LANDSCAPE ARCHITECTS
SURVEYED JFP CHECKED AJM DATUM AHD
A
99 & 101-105 EUMUNDI NOOSA ROAD M2677-09A Combined Detail.dwg
C O N S U L T A N T S JFP URBAN CONSULTANTS PTY LTD ACN 050 414 045 ORIGINAL ISSUE 06-07-2021 TLP DATE:
DRAWN TLP APPROVED AJM ORIGIN (BM) PM170215_RL12.12 ISSUE: DETAILS: DATE: INIT: NOOSAVILLE 6th July, 2021
COPYRIGHT © 2021 JFP URBAN CONSULTANTS PTY LTD. THIS DOCUMENT MAY NOT BE COPIED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS IN PART OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF JFP URBAN CONSULTANTS PTY LTD.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.