Original source · versioned page text
Response to infor request
Callaghan & Toth Consulting Engineers Pty Ltd ABN No. 45140292324 8/41 Sunshine Beach Road Noosa Junction P.O Box 2305 Noosa Heads 4567 Callaghan & Toth yww.callagh: dtoth: ff os 7 : z www.callaghanandtoth.com.au Civil, Environmental & Hydraulic Engineers Ph: 07 5474 9081 Fax: 07 54749041 13" September 2013 File No: 1314 CEO Sunshine Coast Regional Council Locked Bag 72 Sunshine Coast Mail Centre QLD 4560 Attn: Monkeith Kadum, Development Assessment Dear Sir, RE: OPW 13/0022: 2 Lot Subdivision at 411 Black Pinch Road, Cootharaba We are writing on behalf of our clients Hans and Denise Herrle in relation to the OPW information request dated 24-1-13 and Reconfiguration Approval, we enclose plans 1314-01 and 1314-02. 1. House Site: The proposed house site is generally to Cardno Drawing 242001-001, except the area is to be reduced as shown on drawing 1314-02 to allow for fire fighting vehicle turning and garage pad only. The owners propose that to minimize cut and fill and impact a pole home is the most sensible option to enable this house site with views to be used. This change will roughly halve the house site area and reduce the fill height significantly (from 7m to 4m). The total cut and fill will be: 5m cut, 4m fill. While this is more than the 2m amount specified in Condition 12 of the Reconfiguration (REC) Approval a flat area is necessary to comply with OPW requirement for emergency vehicle turn area. As per Condition 11 of the REC Approval a Geotechnical Report for Slope Stability Assessment has been carried out for this site and proposed house site cut/fill depths (see Figure 1 of Cardno Bowler Report 10360ds.12 Dated 6-3-2012). The Report classifies the site as ‘... ‘low likelihood of instability’ therefore the previous Council limit of 2m is considered superceeded as the nominated house site has now been addressed by a Geotechnical Engineer. 2. Fire Fighting Turning area: Please refer to Plan 1314-02 showing turning area for a Fire Fighting vehicle on the house pad area. 3. Passing Bays Proposed: There are three existing locations where passing bays can be formalized with a small amount of earthworks prior to the site, see attached plan 1314-01. Due to the minor nature the works will be marked out on site and confirmed at the pre-start meeting with Council inspector. A separate Operational Works application is not considered necessary and details are shown below. X:\JOBSICT Projects in progress\1314 driveway & passing bays\Correspondence\Response to infor request.doc
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.