Skip to the record
Noosa’s premier civic archive.

Council archive · source document

Decision Notice - MCU23 0163 & OPW23 0199 [As Published] · MCU23/0163

of 5

Text shows just the words. Original shows the document exactly as it was published.

               4.     ASSESSMENT MANAGER CONDITIONS

                      Approved Plans
               1.     Development undertaken in accordance with this approval must generally comply with the
                      approved plans of development. The approved plans are listed in the following table unless
                      otherwise amended by these conditions.

                        Plan No.           Rev.   Plan/Document Name                            Date

                        TJS-SJ-04870-02    B      Layout Plan                                   2 February 2024
                                                  Prepared by The Jetty Specialist

                        TJS-SJ-04870-03    B      Elevation                                     2 February 2024
                                                  Prepared by The Jetty Specialist

                      Currency Period
               2.     The Currency Period for this development approval lapses if all conditions have not been
                      complied with, and the plan of survey lodged with Council for endorsement by 23 February
                      2026, unless an application to extend the currency period is approved by Council.
                      Performance Bond
               3.     Security in the form of a cash bond or trading bank guarantee to the sum of $2,000 must be
                      submitted to Council, to secure performance of all conditions of this approval, prior to the
                      commencement of the works. The cash bond or trading bank guarantee will be returned on
                      performance of the conditions of this approval less any costs incurred by Council in respect
                      of enforcing performance of this permit. Council reserves the right to call upon the bond or
                      guaranteed sum to effect compliance with conditions.
                      General Conditions
               4.     The maximum number of vessels that may be berthed, moored, attached or stored on the
                      structure must not exceed 2.
               5.     The use of the pontoon must not cause any adverse effects on the amenity of the surrounding
                      areas including changes to light, views, air quality and noise.
               6.     Vessels berthed/moored at the pontoon must be located a minimum of 3.0 metres from the
                      prolongation of the property boundaries.
               7.     Vessels and boatlifting devices must be connected directly to the pontoon, and not located
                      side by side or in tandem with another vessel.
               8.     All structures must be designed and constructed such that they are free standing within the
                      waterway and are not connected to or behind the revetment wall.
               9.     All structures must have no detrimental effects on stormwater drains and/or easements.
               10.    A rigid handrail must be fitted on one side of the gangway. The handrail must be of an open
                      design and in accordance with the approved plans.
               11.    No posts or vertical supports of the proposed pontoon are to extend vertically from the
                      structure unless they provide necessary support for the handrail.
               12.    No boatlifting devices are to be attached or moored at the pontoon structure for the purpose
                      of elevating a vessel above the water without Council approval.
               13.    There must be no electrical reticulation system carrying electricity in excess of 24 volts
                      beyond the revetment wall unless all switches and power outlets are positioned above the
                      1%AEP flood level.
               14.    Lighting associated with the use must be designed, installed, operated, and maintained in
                      accordance with Section 3 of AS4282 Control of the Obtrusive Effects of Outdoor Lighting.


                                                                                                       Page 2 of 5
Document Set ID: 22854687
Version: 4, Version Date: 11/03/2024

Used in these records

About this file

File size
149 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - MCU23 0163 & OPW23 0199 [As Published].pdf · 149 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.