Council archive · source document
Attachment 1 - Proposal Plans · 51987.2949.6
Plans and drawings: the text below has words only, no drawings.
9,850 9,000
10,850
1,000 270 9,310 270
C2 C F B A
A1
90
270 2,170 10 10 2,905 90 4,035 270
1,000
bth tub
270
270
270
270
270
270
270
270
1,395 30
Hob
shwr
BHd 470h
16 3,395 30
Robe
shwr
Ens
2,300
1,760
REPLACE
BH 330dx615w
GLASS
ROOF
2575CH Bath 2558CH Bed Rm 2
2,170
2,170
2,170
raked BH
Areas : (Internal Wall, GFA)
2,670
270 2,180 90 1,920 995 90 4,005 30 270
3,700
695
1750h
5,000
sk
3,760
170 2462CH
Existing :
270
3,825 30
650
5,630
2115CH
1,500 90
90
1,500 90
BH 425dx485w
tub
HW
Living : 92.5 m²
5,360
630 1,550 90
540
90
270 2,180 90 dry1,830 90 1,100 90 3,900 30 270
Terrace : 65 m² (incl. planter)
150
L/dry 845 660 480 660 1,260 30
2,421
2555CH vb wm
90
1,940
Robe
10
C2
210
980 3,250 270
TOTAL : 157.5 m²
90
90
90
860 10
WIR
510
10,000
2295CH
840
E Passage Entry E
60 1,530
1,205
2295CH90
9,830
980 280 2,540 155
Entry
1,440
BH dx770w
step step step
950
2545CH
850
460
99
0
880
1,505
305
400
385
390
970 95 55
110
270
320
270 630 965 675 1,075 130
DW
5,600
2,402
E1 270 E1
5,000
30 3,315 130 3,325 110 2,400 270
2,855
2,945
Lounge Kitchenmw
4,350
Bed Rm 1
0 2557CH ubo
2557CH FFL 2570CH 58
ACH
ACH
5,900
F
4,395
160
710 300
130 5,805 30 270
10 90
27-34 SD 27-23 SD Dining
2,560
90
90
90
90
2,560
3,690 2,286
27 ,36
-2
FFL-170
2,500
3S 9
2
2,410
2,670
5,976
2,500
D
27-20 SD
90
90
D1 1,929 D1
995
970
5,000
Step 2723 to slab over
line of slab above 880h Wall over
300
31° Raking wall
31° Raking wall
D 720h blockwork
6,500
D
2,500
glass roof
2,520
4,835
over spa/deck
3,830
4,935
2,590
140
glz bal.
1,520
1,140
glz bal.
800
+320 FFL-220
2,435
440h wall
790
790
190
+660 Planter box
915
STRUCTURAL ENGINEERS :
TOD CONSULTING
315
07 5449 9600
[email protected]
BUILDER : Remove Spa & Hob
Troy Shelley
Remove glass roof & post EXISTING GROUND FLOOR PLAN
Quality Assured Building C 1:100
PO Box 833 B A
Tewantin QLD 4565 F
PH: 0402 200 048 A1 SCALE 1 : 100
ACN: 606938112
Lic No. 1030629 0 5m
CD-02 For Client / Council Approval 12-08-22
PRELIMINARY
DESIGN / DRAWN : ( NOT FOR CONSTRUCTION )
FIGURED DIMENSIONS TO TAKE PRECEDENCE OVER SCALED MEASUREMENTS, CD-01 For Client / Council Approval 27-07-22
Robert Patterson GEOFF COLLINSON ADDITIONS & RENOVATIONS TO RESIDENCE AT 19/1 MORWONG DR,
QBSA Lic.No. 1095554
VERIFY ALL ON SITE DIMENSIONS AND LEVELS PRIOR TO THE COMMENCEMENT
EXSTG-01 For Site Check & Discussion 27-06-22 A3 202213
m : 0401 394 964 OF ANY CONSTRUCTION. CONTRACTOR TO NOTIFY DESIGNER IMMEDIATELY
e : [email protected] OF ANY DISCREPENCIES.
CLIENT JOB DESCRIPTION NOOSA HEADS
ISSUE DESCRIPTION DATE SHT SIZE. DWG NO.
CD.1
COPYRIGHT : No reproduction of all or part of this drawing may be undertaken without the express written permission of the author. NOTE : These drawings to be read in conjuntion with structural engineers drawings
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 1 - Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.