Part 3 of 37 Appendix 1 - Noosa on Weyba Locality Plan MCU12/0208
Plans and drawings: the text below has words only, no drawings.
Very large file (38.7 MB): may take a few minutes to open.
Column 1 Column 2
Specific Solutions Probable Solutions
S5.1 For new buildings or structures 0
Flooding and Drainage
additions of more than 50m2 gross
05 Buildings and other works are
floor area to an existing building 0
designed and sited to- structure, floor levels for habitable
flood free to rooms are-
a) provide access
premises and flood free habitable a) for areas where minimum floor levels
are available-not less than the
areas;
specified level;
b) allow only minor, short term and
of non-habitable
b) for areas where flood modelling is
infrequent flooding
available-a minimum of 500mm
areas;
above the modelled flood level; and
c) ensure carparking areas can be
c) for areas where flood modelling is not
adequately drained; available, a minimum of 500mm
d) ensure drainage does not adversely above the highest known flood level;
impact upon other premises; and
AND
e) ensure filling or excavation does not
adversely impact upon other
S5.2 Where Council infrastructure is
premises by- available-
i. causing ponding of water on a) any drainage (from buildings and
the site or nearby land; land)flows to that infrastructure; and
ii. increasing flooding, which b) the infrastructure has the capacity to
adversely affects the safety accept any additional loading;
AND
or use of any land upstream
and downstream; and
iii. S5.3 For Residential Uses-
adversely affecting the flow
of water in any overland flow a) where slab on ground construction is
used, filling does not extend more than
path. 1 m beyond the building footprint and
access to car parking areas, measured
from outer walls of the building; or
b) the design consists of a suspended
floor construction;
AND
55.4 Car parking and maneuvering areas
are constructed at a level that
permits the parking area to drain
from the site by gravity means,
without the need for mechanical
pumping; or
55.5 Basements for residential uses have
flood immunity above the 0100
where alternative means to
mechanical pumping are used to
achieve such immunity; or
55.6 Basements for non-residential uses
have flood immunity above the
0100 that may be achieved by
35
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 3 of 37 Appendix 1 - Noosa on Weyba Locality Plan MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 38.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.