Column 1                                            Column 2

Specific Solutions                                  Probable Solutions



                                                    S5.1    For new buildings or structures 0
Flooding and Drainage
                                                            additions of more than 50m2 gross
05     Buildings and other            works   are
                                                            floor area to an existing building 0
     designed and sited to-                                 structure, floor levels for habitable
             flood         free                to           rooms are-
  a) provide                       access

     premises and         flood free habitable        a) for areas where minimum floor levels
                                                           are    available-not       less    than     the
     areas;
                                                           specified level;
   b) allow only minor,       short    term   and
                              of non-habitable
                                                       b) for areas where flood modelling is
      infrequent flooding
                                                           available-a      minimum      of    500mm
     areas;
                                                           above the modelled flood level; and
  c) ensure carparking         areas    can    be
                                                      c) for areas where flood modelling is not
     adequately drained;                                   available, a   minimum   of 500mm
  d) ensure drainage does not adversely                    above the highest known flood level;

     impact upon other premises; and
                                                    AND
  e) ensure filling or excavation does not
     adversely     impact    upon    other
                                           S5.2            Where Council infrastructure is
     premises by-                                          available-
           i.     causing ponding of water on         a) any drainage (from buildings and
                  the site or nearby land;               land)flows to that infrastructure; and
           ii.    increasing flooding, which          b) the infrastructure has the capacity to

                  adversely affects the safety           accept any additional loading;
                                                    AND
                  or use of any land upstream

                  and downstream; and
           iii.                                     S5.3 For Residential Uses-
                  adversely affecting the flow
                  of water in any overland flow       a) where slab on ground construction is
                                                      used, filling does not extend more than
                  path.                               1 m beyond the building footprint and
                                                      access to car parking areas, measured
                                                      from outer walls of the building; or
                                                      b) the design consists of a suspended
                                                       floor construction;

                                                    AND


                                                    55.4    Car parking and maneuvering areas
                                                            are  constructed at a level that
                                                            permits the parking area to drain
                                                            from the site by gravity means,
                                                            without the need for mechanical
                                                            pumping; or


                                                    55.5    Basements for residential uses have
                                                            flood   immunity      above       the    0100
                                                            where       alternative       means         to
                                                            mechanical      pumping      are    used    to
                                                            achieve such immunity; or



                                                    55.6    Basements for non-residential            uses

                                                            have    flood     immunity       above     the
                                                            0100 that       may    be    achieved       by


                                                                                                        35

Used in these records

About this file

File size
38.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 3 of 37 Appendix 1 - Noosa on Weyba Locality Plan MCU12_0208.pdf · 38.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.