Skip to the record
For the highest quality transcripts.

Original source · versioned page text

RFI - 21370-001-Rev1 66 Seaview Tce

of 52

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                            TERMS USED ON LOGS


DRILLING/EXCAVATION METHOD
AD*        Auger Drilling          RA      Rotary Air                          BH         Tractor Mounted Backhoe
ADH        Hollow Auger            RD      Rotary Blade or Drag bit            EX         Tracked Hydraulic Excavator
HA         Hand Auger              RT      Rotary Tri-cone bit                 HMLC       Core – 63mm
*T         TC-Bit                                                              HQ         Core – 63mm
*V         V-Bit                                                               NMLC       Core – 47mm
                                                                               NQ         Core – 52mm
                                                                               R          Ripper
                                                                               RH         Rock Hammer
WATER
GROUNDWATER NOT             The observation of groundwater, whether present or not, was not possible due to drilling water,
OBSERVED                    surface seepage or cave in of the borehole/test pit.
GROUNDWATER NOT            The borehole/test pit was dry soon after excavation. However, groundwater could be present in
ENCOUNTERED                less permeable strata. Inflow may have been observed had the borehole/test pit been left open
                           for a longer period.

SAMPLING AND TESTING
SPT                Standard Penetration Test to AS1289.6.3.1-2004
5,4,10 N=14        5,4,10 = Blows per 150mm. N = Blows per 300mm penetration following 150mm seating
30/65mm            Where practical refusal occurs, the blows and penetration for that interval are reported
RW                 Penetration occurred under the rod weight only
HW                 Penetration occurred under the hammer and rod weight only
HB                 Hammer double bouncing on anvil
DS                 Disturbed sample
BDS                Bulk disturbed sample
SV                 Field shear vane test expressed as uncorrected shear strength (sv = peak value, sr = residual value)
PP                 Pocket penetrometer test expressed as instrument reading in kPa
U50                Thin walled tube sample - number indicates nominal sample diameter in millimetres
DCP                Dynamic cone penetration test
CPT                Electronic cone penetration test
CPTu               Electronic cone penetration test with pore pressure (u) measurement



                                                                                                                       Rev1
                                                                                                                 February 2021
Log in to download the original file

RFI - 21370-001-Rev1 66 Seaview Tce.pdf · 9.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.