64 Pheasant Lane, Doonan septic design

of 12

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                 Sunshine Coast Office
                                                                                 PO Box 6218
                                                                                 Mooloolah Valley Q4553

                                                                                 P. 0407 887 321
                                                                                 E. [email protected]

    BioWater Designs Pty Ltd
    QBCC Lic 1049265




                                           NEW DWELLING


                                     SITE & SOIL EVALUATION


                                               Lot 36 SP 139155

                                                Area: 4000.37m2

                                       Address: 64 Pheasant Lane, Doonan

                                            Date: 27th October 2020

                                    Reference No: Noosa/2020/AES/64Pheasant




INDEX:

1.0 Introduction:
2.0 Site Description:          p2
3.0 Soil Investigation:                                       IMPORTANT DIRECTION
                                                              Do not install from this design until it is
3.3 Soil Classification                                       Stamped and Approved by the Local Authority.
4.0 Recommendations:           p3                             Council may make changes to this design as part
                                                              of the approval process. Only install from Stamped
5.0 Design Calculation                                        Approved Plans and refer to the Approval Permit for
                                                              possible changes.
5.1 AES Infiltration Bed Design: p4
AES Calculator            p5
7.0 Design Drawings       p6
7.1 Design Drawings       p7                                                                               reuse
Borelogs               p8-9
Appendix A - Inspection Port p10                                                                           recycle

Site Classification        p11                                                                             retrieve
Articulation Joints Illustration     p12
                                                                        C Copyright Lance Picton 2020 design & content. 1/12
Log in to download the original file

64 Pheasant Lane, Doonan septic design.pdf · 2.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 11 pages

Page 2

1.0 Introduction:
Biowater Designs Pty Ltd, in accordance with AS/NZS1547-2012 ( Domestic Wastewater Management ) and the
Queensland Plumbing & Wastewater code (QPW) 2019 Version 1, was commissioned to undertake a Site & Soil
Evaluation in the Noosa Council at 64 Pheasant Lane, Doonan.

The results form the basis of our recommendations for on site wastewater disposal.

Original site investigation and field work was performed on Tuesday 17th September 2020 after a period of wet weather.

The investigation was undertaken to determine the soil profile and Long Term Acceptance Rate (LTAR) of the site in
order to accommodate a proposed new 4 bedroom dwelling.

NOTE: This evaluation was undertaken at the owner’s request after considerable discussion regarding environmental
issues of this site and preferred design of the Land Application Area.
.


2.0 Site Description:
2.1 Existing Buildings: None


2.2 Site Factors:

The site is an acreage allotment the area is 4000.37m2.

The proposed Land Application Area is moderately sloping (6%) to the North

The proposed Land Application Area will have good exposure to sun and wind following the planned removal of trees.

Erosion, mass movement or land slip was not observed on this site. Rock outcrops are not evident on this site.

Vegetation on this site currently consists of small to large trees.

There are no dams or bores on this site or adjoining properties within the required setbacks of the proposed Advanced
Enviro-Septic Bed.

There is a small creek / intermittent waterway downhill of the proposed AES Bed. Setback requirements under the
Queensland Plumbing and Wastewater Code for Advanced Secondary Effluent are obtainable.

Ground water was not encountered on this site during our investigation to a depth of 2000mm.

There is no evidence of fill in the proposed Land Application Area.

Rain water will transverse this site from adjoining properties during heavy rains.

Concentrated run-off from this property will transverse adjoining properties during heavy rains.

Soils were moist and there is no evidence of soil surface cracking in the LAA. No evidence of compaction or seepage
areas. Salinity is not evident.


3.0 Soil Investigation:

3.1 Drainage Pattern: Linear Planar
3.2 Method:
Soil Testing for the site was conducted by Global Testing on 8th July 2020 to a depth of 2000mm.

The soils were visual one textually classified in accordance with Table E1 AS/NZS 1547:2012. The soils were
predominately grey - brown in colour. Weakly structured Silty Sand - Clayey Sand - Sandy Clay.

Slight coherence; forms a fragile cast that just bears handling; gives a very short
5mm ribbon that breaks easily; discolours the fingers. Category 2 adopted.
The Site Classification was also conducted by Global Testing and indicate class “P” due to dense growth of trees.            See page 11.
Articulation Joints are to be designed by a suitable qualified person.
                                                                                     C Copyright Lance Picton 2020 design & content.   2/12

Page 3

3.3 Soil Classification



                                                   Soil Classification - Adopted
        Borehole Nos                                                                                1&2
        Soil Category Adopted                                                                         2
        Indicative Drainage                                                                     Well Drained
        Structure                                                                                  Weakly
        Texture                                                                                 Clayey Sand
        Indicative Permeability P (m/d) as Ksat*                                                     >3.0
        Recommended DLR (AS/NZS 1547 / 2012)                                                          50




     4.0 Recommendations:
     4.1 Treatment Facility:
     The on-site treatment facility to service the new dwelling is to be an Advanced Enviro-Septic System (AES). This
     system has a Chief Executive Approval # 14/2014 for Advanced Secondary Effluent. The Person Equivalent (PE) for
     this system is to be no less than 6.

     A new min 4450lt septic tank is to be installed to service the new dwelling and must comply with AS/NZS:1546.

     All wastewater from the new dwelling is to be directed to the new septic tank then to the AES bed.

     The Land Application Area is to be an Advanced Enviro-Septic Infiltration Bed of 29.6m2.




      5.0 Design Calculation
      The serviceable life of the Land Application Area will be compromised if the design flow is exceeded. Any
      proposed changes to the position of the Land Application Area, System Type or House Design will require a
      reassessment of this site. For our calculations we have assessed the design flow as follows:

                                                    Design Calculation
         DLR (mm/d) (secondary quality effluent)                                                     50
         Hydraulic load (lt/day/person) Tank Water / 4 bedrooms                                      120
         Design Flow Q (lt/day)   PE: 6                                                              720
         Design sizing calculation                                                           L = Q /(DLRxW)
                                                                                                = (720 / 50)
         Disposal area A+B (square metres) AS/NZS1547:2012 + downhill loading                       26.6m2
         Nominated Configuration (metres) AES System Design Calculations               = 12.6 x 2.35m (L xW) 29.6m2
         A new 4450L Septic Tank is required.                                                AES System EP 6




                                                                                  C Copyright Lance Picton 2020 design & content. 3/12

Page 4

5.1 AES Infiltration Bed Design.            Advanced Enviro-Septic System

The AES Bed Design is to be a gravity fed, below ground system. See system design drawings page 6.

The total bed base required is 29.6m2 (12.6m x 2.35m). Bed is to be installed as shown on the site plan. See drawings page 6 for
bed profile. A minimum 4m setback is required to any tree.

Coarse washed sand will be referred to as “system sand” and must meet the specifications of the system manufacturer.
System sand will need to be placed around AES pipework and for the infiltration area as shown on the attached drawings.

System pipe bed dimensions (Area A) are 12.6m x 1.35m and a total minimum sand depth of 750mm. 300mm of course washed
sand is to be spread to form a base and 2 rows of 4 lengths of AES pipes installed as per the attached drawings.

A further infiltration area 12.6m2 (12.6m x 1m) (Area B) is to be constructed around and below the pipe bed as per the site
drawings and a minimum of 150mm system sand to be spread over the entire infiltration area.

Pipes are to be covered by a minimum of 150mm of system sand. A further 150mm of site soil is to be mounded over the sand to
prevent surface water entering the bed. After all settlement the AES Bed is to have a minimum 150mm cover of site soil.

Beds are to be constructed in accordance with the AES Design and Installation Manual and all plumbing works in accordance with
the QPW code. All site work is to be carried out by a licenced plumber and all AES horizontal pipes layed with the aid of a laser
or dumpy level to ensure absolute compliance with the manufacturers installation guidelines. This is critical for correct operation.

Oxygen Demand Vents are to be installed as per the AES Design & Installation Manual. The high vent (100mm - on the house)
must be a minimum of 3m higher than the AES low vent and provide unrestricted air flow through the entire system. (See attached
drawing for illustrations.)

Two Inspection Ports are to be installed, one in the centre of the pipe bed and another at the furthest point from the influent to AES
Pipes. See Installation Instructions Appendix A - page 9.

Care must be exercised to prevent machinery access on the AES bed during and after construction.




      6.0 Setback Regulations:

                                                                                  Secondary          Advanced Secondary
        Recommended Separations Distances - Surface Irrigation
                                                                                  Effluent                Effluent
          Dwellings & recreation areas                                                10m                   10m
          Water edge of swimming pools                                                 6m                    6m
          Property boundaries, paths & walkways                                    2m uphill             2m uphill
                                                                                   4m down hill          4m down hill
          Top of bank of permanent water course, creek, lake, waterway etc.             30m                 10m

          Bore or Dam for domestic or stock use                                         30m                   10m
          Vertical depth of seasonal water table                                       0.6m                   0.3m
          In ground potable water tank. Note some authorities require 15m               6m                     6m
          Sub-Surface Irrigation same as above except for;
         Dwelling & recreation areas                                                    4m                     4m

     NOTE: The local government authority may upon considering the public health and environmental risks
     reduce or increase the distances in the above table.
    Regards,




    Lance Picton jp.
    Site Classifier
    QBCC Lic: 1049265
                                                                                     C Copyright Lance Picton 2020 design & content.   4/12

Page 5

5/12


[OCR of page images]
 

 

ADVANCED
ENVIRO-SEPTIC" Advanced Enviro-septic Design Calculator V8.8 ©

‘Always The First Option”

 

Leader in Passive Solutions
Site

 

 

 

 

‘Address. 64 Pheasant Lane, Doonan State Qid Post Code 4562
Client Scott Elliott Date of Site Visit
Name
Designer Designers Ph
SSIENETS | i owater DesignsPty Ltd esigness 54 947 620 Number 1049265
Name Number a
“ Plumber Ph Plumb / Drainer
Plumber Number Lic Number
Council Designers AES
‘Area NOOSA Cert Number AERBROO00001 Date 27.10.2020

 

 

This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.

IMPORTANT NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY s
Is this a new installation Y or N y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of person 6 a septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constrants 2 >>The maximum length of a single AES pipe run is 30 meters
Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY 2
Design Loading Rate based on site & soil evaluation DLR (mm/day) 50
Bore log depth below system Basel area 600 >>Min depth below basel area 600mm check water table/restrictive laye
Enter System footprint Slope in % for std AES systems to calc extension 6 >>Consideration reqd for Sloping sites. Ref AS1547. refer comment.
Is this design a gravity system with no outlet filter? Y or N y >> A House Vent & LOW VENT required on this system

 

PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES

 

 

 

" The outcome must be important to everyone.

- All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547.

- Plumbers are reminded to practice good construction techniques as per AS 1547 & as provided on AES installation instructions supplied with components.

AES System Calculator Outcomes POST

 

 

 

 

 

 

 

 

 

  

 

 

 

 

Total System load - litres / day (Q). 720 vd AES System __| System Extension
Min Length of AES pipe rows to treat loading 20 Im Lth m: ) 12.6 12.6
Number of FULL AES Pipe lengths per row 4 Iths Width m:(W 1.35 1.00
and 5
Total Capacity of AES System pipe in Litres 1696 Itr, |_Denth : 0.75 0.15
Area m2 17.0 12.6
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y] |
IF YOU WISH TO USE A TRENCH EX1 ‘SION DESIGN OPTION ENTER "Y" Enter Custom Width in metre
AES INFILTRATION FOOT PRINT AREA- L=Q/(DLRxW) | Length Width Minimum AES foot print required .
for this Basic Serial design is 12.6 x 2.35 = 29.6 m2 total

 

 

 

 

PES CHE ROME ar Oe Cee UMC eke
AES-PIPE AES 3 mtr Lths required 8 Ith oe 5
mina requ . Digitally signed by
AESC AESC Couplings required 6 ea Steve Dennis
AESO AESO Offset adaptors 4 ea DN: cn=Steve
Dennis, o=Chanda
AESODV AES Oxgen demand vent 1 ea

Enviromental,

AES-IPB AES 100mm Inspection point base 2 ea @ ADVANCED ___ ou=Resign Review,

‘nawestarenoe sowtin” email=designrevie

 

 

AES E AES Speed Fl: Equalis e: .
qu peed Flow Equaliser ca weet
‘AES DESC Double Offset Adaptors ea septic.com.au,
TOTAL SYSTEM SAND REQUIRED (Guide Only) 18 m3 c=AU
Date: 2020.10.28
PLEASE email your AES CALC and Drawings to 08:37:39 +10'00'

[email protected].AU_

 

[email protected]

 

 

> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil
conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer.

> Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.

> AES pipes can be cut to length on site. They are supplied in 3 meter Iths only.

5/12

 

AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016

 

 

 

 

Page 6

7.0 Design Drawings                                                                                                                                                                                                       level
                                                                                       Inspection Port to be installed
This plan is Site Specific for 64 Pheasant Lane Doonan.                                between AES Pipes - see
                                                                                                                                                                                                                  AES pipe                   pack sand
                                                                                       Appendix Page 9
                                                                                                                                                                                                                                                 under
                                                                                       for installation instructions
                                                                                                                             12.6m


                                                                                                                              12m

        Inlet




                                                                                                                                                                                                                                         1350mm
                                                                                                                                    Inspection Port




                                                                                                                                                                                                                                                         2350mm
      Low Vent



 300mm
                                                      Area A
 Ground level

                                                                                                                                                                                                     Inspection Port to be installed
                                                                                                                                                                                                     at furthest point from Influent
                                                                                                                                                                                                     to AES Pipes - see Appendix Page 9
                                                                                                                   Area B           Infiltration Extension Area                                      for installation instructions
                                                                                                                                    12.6m x 1m x 150mm system sand.

                                                                                                                                                                                                             Inspection Port


                                                                                                                                                                                                                                                                  AES pipe
                                                                                                                                                                                                                                                         150mm



                                                                                                                                                                                                                                                  300mm                        300mm

                                                                                                                                                                                                                                                    8/9
                                                                                                                                                                                                                                                   9/9300mm        150mm
                                                                                                                                                                                                                                                                             Sand
                                                                                                                         Inspection Port             300mm
                                                                                                                                                                                   Inspection Port                                                   AES Sand Coverage Minimums
                                                                                                                                                                                                     Natural Ground Level
                                                                                                                                                           150mm                                                                  6%
                                                                                                                            150mm



                                                                                                                                                        300mm

                                                                                                                         300mm
                IMPORTANT NOTES PLEASE READ.
                                                                                                                                    1350mm                                    1000mm
    The installer MUST refer to the Advanced Enviro-Septic Design & Installation
    Manual provided. If you do not have a copy of this manual please contact Chankar
    Environmental and a copy will be emailed FREE.

    Sections C, D, & E of the Design and Installation Manual are of particular relevance
    when installing an Advanced Enviro-Septic System.
                                                                                                                             IMPORTANT DIRECTION
    THIS IS NOT A SEPTIC TRENCH AND MUST BE INSTALLED AS PER THE                                                             Do not install from this design until it is
    AES DESIGN AND INSTALLATION MANUAL GUIDELINES.                                                                           Stamped and Approved by the Local Authority.
                                                                                                                             Council may make changes to this design as part
                                                                                                                             of the approval process. Only install from Stamped
    Ensure you have the correct sand and all fittings to complete the installation if you                                    Approved Plans and refer to the Approval Permit for                                Imported sand (course washed)
    are unsure of anything please contact Chankar Environmental (07) 54 744 055 or                                           possible changes.
    Biowater Designs 54 947 620.                                                                                                                                                                                Backfill with site soil min 150mm cover over sand
                                                                                                                                                                                                                and mound soil over bed to prevent water access.


                                                                                                                                                                                                                                       C Lance Picton 2020 all rights reserved 6/12

Page 7

   SITE PLAN: This plan is site specific for 64 Pheasant Lane Doonan.




                                                                                            This Drawing is not to SCALE




                                                                                                                              AES bed 12.6 x 2.35
                                                                                                                              (29.6m2) see Design Drawings
                                                                                                                              for more detail.

                                                                                                                  BH#
                                                                                                                  BH#2




                                                                                                                                 4m
                                                                                                         4m



                                                                                                                              BH#
                                                                                                                              BH#1



       Notes: This report is based on information and
       plans provided by the owner in addition to the
       site information at the time of investigation.
       It does not take into account any event, whether
       by human intervention and/or by nature that occurs
       after the date of the site investigation which affects
       the results and findings contained within this report.

       In the event that the site conditions change or
       the proposed development is altered in any way,
       this office is to be notified to determine what if any
       affect they may have on this design. Should a
       re-design be required, further fees may apply.




        IMPORTANT DIRECTION
        Do not install from this design until it is
        Stamped and Approved by the Local Authority.
        Council may make changes to this design as part
        of the approval process. Only install from Stamped
        Approved Plans and refer to the Approval Permit for
        possible changes.




              N



Biowater Designs Pty Ltd           Plan of:                     Client:             This plan to be read in conjunction with the
                                                                                                                                    All plumbing works to be performed by a licenced plumber
PO Box 6218                        Lot 36 SP 139155             Scott Elliott       attached report.
                                                                                                                                    and must comply with the Queensland Plumbing &
Mooloolah Valley Q 4553            64 Pheasant Lane,            Ph: 0401 998 527    The proposed Land Application Area must be
                                                                                                                                    Wastewater code. LAA setbacks must comply with
Ph: 07 54 947 620                  Doonan                                           installed and positioned as per this plan.
                                                                                                                                    AS/NZS1547:2000 as setout on page 4 of this report.
M: 0407 887 321                                                                     Construction of any permanent structures
                                                                                    within the designated area is prohibited.
Site Classifier:                                                                                                                                                 Site Area: 4000.37m2
                                   Local Authority:             Date:               Care must be taken to ensure no traffic or fill
Lance Picton jp                                                                                                                     SCALE: 1: 300 @ A3           LA A: 29.6m2
                                   Noosa Council                27th October.2020   in the designated area during construction.
QBCC Lic 1049265

Page 8

Borelogs:




            8/12


[OCR of page images]
Borelogs:

 

GLOBAL TESTING

 

THE ONLY NAME IN SOILS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SOIL PROFILE REPORT
CLIENT: Scott Elliott. AUTHORISED _ Scott Elliott.
BY:
PROJECT: 64 Pheasant Lane, DATE TESTED: 08/07/2020
Doonan. JOB NO: 20/0584
Drilling Method: Jacro 105 100mm. Borehole
No.1
Depth Description PENET. Est. Bearing
(mm) . es Capacity
(kPa)
1 [2[3j4
0 SILTY SAND (SM)-Fine to coarse grained, thal
grey, moist, loose. {
100 2 50
200 2
300 CLAYEY SAND (SC)-Fine to coarse 3 100
grained, brown, medium plasticity fines,
moist, medium-dense.
400 10
500 12
600 10
700 >20 Tree Roots.
800
900
1000
1100
1200
1300
1400 SANDY CLAY (CH)-High plasticity, brown,
fine to coarse sand, moist, stiff.
1500
1600
1700
1800
1900
2000 Hole Terminated.
2100
2200
2300
2400
2500

 

 

 

 

 

 

 

 

Page | 4 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code

20/0584

 

Page 9

9/12


[OCR of page images]
GLOBAL TESTING

THE ONLY NAME IN SOILS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SOIL PROFILE REPORT
CLIENT: Scott Elliott. AUTHORISED _ Scott Elliott.
BY:
PROJECT: 64 Pheasant Lane, DATE TESTED: 08/07/2020
Doonan. JOB NO: 20/0584
Drilling Method: Hand Auger 100mm. Borehole
No.2
Depth Description PENET. Est. Bearing
(mm) Slows pe. Phen) Capacity
(kPa)
1] 2 Jaf4
0 SILTY SAND (SM)-Fine to coarse grained,
grey, moist, loose.
100 2 50
200 SILTY SAND (SM)-Fine to coarse grained,
grey, moist, medium-dense. 3 100
300 CLAYEY SAND (SC)-Fine to coarse 10
grained, brown, medium plasticity fines,
moist, medium-dense.
400 10
500 >20 Tree Roots.
600
700
800
900
1000
1100
1200
1300 SANDY CLAY (CH)-High plasticity, brown,
fine to coarse sand, moist, stiff.
1400
1500 Hole Terminated.
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

 

 

 

 

 

 

 

 

 

Page | 5 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
20/0584

Page 10

                                                                                                                10/12




                                                                         -
                                                                         o
                                                                                                  t-
                                                                                                  lL
                                                                                                  o
                                                 {U                      E
                                                                         E                        l-
                                                                                                  5
                                                 \t
                                                 ()
                                                                         5
                                                                         3'                       o
                                                                         lr                dr-
                                                                         2                 2
                                                                         o
                                                 $u                      C'
                                                                                           td
                                                                                           c'
                                                 63                      E
                                                                          o
                                                                          L
                                                                                           !,
                                                 o\1
                                                 ts                      !(t
                                                                         td
                                                                         iE
                                                                         CI
                                                 H*                      UI
                                                                   -,li H
                                                                   l-
                                                                   l-
                                                                   F
                                                                   tJ
                                                                   ."
                                                                   lrl
                                                                   o
                                                                   E
                                            a                      o-
                                            =
                                            6                                  |o    rO
                                                                                     tF
                                                                                                       rt
                                                                                       t                    a
                                                                              (F     1a-               rF
                                                                              .?
                                            F                                 o  a
                                                                                     o                 3    a
                                            g                                 ct     ct                C}
                                            Ut
                                                                         u
                                                                         I
                                                                         l-                            $
                                                                   0*
                                                                   ut i;
                                                             $
                                                             {
                                                       051   il    9d
                                                             ln    as
                                                             =:
                                                             HR r inz
                                                                  l{ut
                                                             IFi
                                                             F$E
                                                             €rt
Appendix A - Inspection Port Installation




                                                                                            t.,;.o
                                                                                                       -
                                                                                                       J
                                                                                            E
                                                                                            LlE
                                                                                               6
                                                                                            IK
                                                                                            3tr
                                                                                            i5
                                                                                            iE,I
                                                                                            HE
                                                                                            zvt
                                                                                                g,
                                                                                            Ei
                                                                                             .a
                                                                                            1?N
                                                                                                       .l
                                                                                            rd h,
                                                                                            l-F
                                                                                            9?

Page 11

11/12


[OCR of page images]
GLOBAL TESTING

THE ONLY NAME IN SOILS

 

QBCC Licence No, 1018403

PH: 07 54 740 900

3/53 Gateway Drive, Noosaville 4566
Email: [email protected]

20/0584 SITE CLASSIFICATION REPORT
SCOTT ELLIOTT.

PROPOSED RESIDENCE.
No.64 Lot 36 PHEASANT DOONAN.
10/07/2020

 

1, INTRODUCTION
The purpose of this report is to classify the subject allotment in accordance with Australian
Standard 2870 - 2011 ‘Residential Slabs and Footings’. From this classification, a footing
system can be recommended for the structure so as to allow adequate performance of the
footings under the soil conditions determined at the site.
Trees: This allotment has a dense growth of large sized trees on & adjacent to the
proposed site, Global Testing recommends an experienced arborist be commissioned to
quantify the existing size, location, predicted maximum height and type of these trees to
aid in the design process. It is the responsibility of the designing engineer to apply the
principals of AS2870-2011 Appendix H "Guide to Design of Footings for Trees". The
classification herein excludes the effect of trees on the site.

2. SITE DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of Allotment Residential
Vegetation (Building Envelope) Sparsely grassed/ Dense undergrowth/ Dense
growth of large sized mature trees
Vegetation (Allotment) Sparsely grassed/ Dense undergrowth/ Dense
growth of large sized mature trees
Road Status Sealed
Slope 6% to the North
Surface Water will Drain Towards The North
Will Surface Water from adjoining No
allotments traverse this site?
Does the site have any watercourses An Intermittent Watercourse is to the rear
Surrounding Allotments
Left Acreage
Right Acreage
Rear Acreage
Depth to Weathered Rock Nia
Depth to Water Table Nia

 

 

3. SITE CLASSIFICATION AND TARGET STRATA
Based on the findings of the site investigation, the classification of the site is considered to
conform to:

CLASS “ P ” (Due to the dense growth of trees-
See Target Stratum).

PLEASE NOTE: Ef not for the dense growth of trees encountered, this site would
have the characteristics of an “M” Site.

in accordance with Australian Standard 2870 - 2011, ‘Residential Slabs and Footings,
Construction’.

Page | 1 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
20/0584

11/12

 

Page 12

Illustration Only: Articulated Plumbing Joints




                                                 12/12


[OCR of page images]
 

 

Illustration Only: Articulated Plumbing Joints

 

ee Vent pipe
Ny

ARTICULATION SWIVELS

 

 

 

 

 

e Overtow pipe
weeonday
Liquid level eumes beatrert
\ éé t Pipe caryirg waste fan
wy eee ener ee

 

 

 

 

 

 

 

 

  

 

 

 

 

 

+
Oweding wal
ij : ‘Sudge Com tau
15° ARTICULATION MOVEMENT =
The comection method prevents the transfer of stress 2/3 tengh w3
moverrert athe sde d he ppewak.
JAS-ANZ Drawing Na SP 108 NOTORAWN TO SCALE
i minnnatevoe oes SOILS RATED @ H2, E, P
i as | Roma tymeemiaekacwesom. | eS,
| ~ | COMPANY | STORM PLASTICS (SA) Pty Lid _ PLASTICS
symm cetns | DORANGRADE | _To suit W'S soll classification | pe
Sep karo | pPEMATERAL | Poly Vinyl CNoide-PVC | JULY 2012 ®|

 

 

 

 

12/12 /)

 