64 Pheasant Lane, Doonan septic design

of 12

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

5/12


[OCR of page images]
 

 

ADVANCED
ENVIRO-SEPTIC" Advanced Enviro-septic Design Calculator V8.8 ©

‘Always The First Option”

 

Leader in Passive Solutions
Site

 

 

 

 

‘Address. 64 Pheasant Lane, Doonan State Qid Post Code 4562
Client Scott Elliott Date of Site Visit
Name
Designer Designers Ph
SSIENETS | i owater DesignsPty Ltd esigness 54 947 620 Number 1049265
Name Number a
“ Plumber Ph Plumb / Drainer
Plumber Number Lic Number
Council Designers AES
‘Area NOOSA Cert Number AERBROO00001 Date 27.10.2020

 

 

This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.

IMPORTANT NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY s
Is this a new installation Y or N y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of person 6 a septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constrants 2 >>The maximum length of a single AES pipe run is 30 meters
Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY 2
Design Loading Rate based on site & soil evaluation DLR (mm/day) 50
Bore log depth below system Basel area 600 >>Min depth below basel area 600mm check water table/restrictive laye
Enter System footprint Slope in % for std AES systems to calc extension 6 >>Consideration reqd for Sloping sites. Ref AS1547. refer comment.
Is this design a gravity system with no outlet filter? Y or N y >> A House Vent & LOW VENT required on this system

 

PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES

 

 

 

" The outcome must be important to everyone.

- All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547.

- Plumbers are reminded to practice good construction techniques as per AS 1547 & as provided on AES installation instructions supplied with components.

AES System Calculator Outcomes POST

 

 

 

 

 

 

 

 

 

  

 

 

 

 

Total System load - litres / day (Q). 720 vd AES System __| System Extension
Min Length of AES pipe rows to treat loading 20 Im Lth m: ) 12.6 12.6
Number of FULL AES Pipe lengths per row 4 Iths Width m:(W 1.35 1.00
and 5
Total Capacity of AES System pipe in Litres 1696 Itr, |_Denth : 0.75 0.15
Area m2 17.0 12.6
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y] |
IF YOU WISH TO USE A TRENCH EX1 ‘SION DESIGN OPTION ENTER "Y" Enter Custom Width in metre
AES INFILTRATION FOOT PRINT AREA- L=Q/(DLRxW) | Length Width Minimum AES foot print required .
for this Basic Serial design is 12.6 x 2.35 = 29.6 m2 total

 

 

 

 

PES CHE ROME ar Oe Cee UMC eke
AES-PIPE AES 3 mtr Lths required 8 Ith oe 5
mina requ . Digitally signed by
AESC AESC Couplings required 6 ea Steve Dennis
AESO AESO Offset adaptors 4 ea DN: cn=Steve
Dennis, o=Chanda
AESODV AES Oxgen demand vent 1 ea

Enviromental,

AES-IPB AES 100mm Inspection point base 2 ea @ ADVANCED ___ ou=Resign Review,

‘nawestarenoe sowtin” email=designrevie

 

 

AES E AES Speed Fl: Equalis e: .
qu peed Flow Equaliser ca weet
‘AES DESC Double Offset Adaptors ea septic.com.au,
TOTAL SYSTEM SAND REQUIRED (Guide Only) 18 m3 c=AU
Date: 2020.10.28
PLEASE email your AES CALC and Drawings to 08:37:39 +10'00'

[email protected].AU_

 

[email protected]

 

 

> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil
conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer.

> Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.

> AES pipes can be cut to length on site. They are supplied in 3 meter Iths only.

5/12

 

AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016

 

 

 

 
Log in to download the original file

64 Pheasant Lane, Doonan septic design.pdf · 2.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.