Original source · versioned page text
64 Pheasant Lane, Doonan septic design
5/12 [OCR of page images] ADVANCED ENVIRO-SEPTIC" Advanced Enviro-septic Design Calculator V8.8 © ‘Always The First Option” Leader in Passive Solutions Site ‘Address. 64 Pheasant Lane, Doonan State Qid Post Code 4562 Client Scott Elliott Date of Site Visit Name Designer Designers Ph SSIENETS | i owater DesignsPty Ltd esigness 54 947 620 Number 1049265 Name Number a “ Plumber Ph Plumb / Drainer Plumber Number Lic Number Council Designers AES ‘Area NOOSA Cert Number AERBROO00001 Date 27.10.2020 This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer. IMPORTANT NOTES Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY s Is this a new installation Y or N y >> Minimun single vent size is 80mm or 2 x 50mm house vents Number of person 6 a septic tank outlet filter is NOT RECOMMENDED Daily Design Flow Allowance Litre/Person/Day 120 Number of rows required to suit site constrants 2 >>The maximum length of a single AES pipe run is 30 meters Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY 2 Design Loading Rate based on site & soil evaluation DLR (mm/day) 50 Bore log depth below system Basel area 600 >>Min depth below basel area 600mm check water table/restrictive laye Enter System footprint Slope in % for std AES systems to calc extension 6 >>Consideration reqd for Sloping sites. Ref AS1547. refer comment. Is this design a gravity system with no outlet filter? Y or N y >> A House Vent & LOW VENT required on this system PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES " The outcome must be important to everyone. - All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547. - Plumbers are reminded to practice good construction techniques as per AS 1547 & as provided on AES installation instructions supplied with components. AES System Calculator Outcomes POST Total System load - litres / day (Q). 720 vd AES System __| System Extension Min Length of AES pipe rows to treat loading 20 Im Lth m: ) 12.6 12.6 Number of FULL AES Pipe lengths per row 4 Iths Width m:(W 1.35 1.00 and 5 Total Capacity of AES System pipe in Litres 1696 Itr, |_Denth : 0.75 0.15 Area m2 17.0 12.6 USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y] | IF YOU WISH TO USE A TRENCH EX1 ‘SION DESIGN OPTION ENTER "Y" Enter Custom Width in metre AES INFILTRATION FOOT PRINT AREA- L=Q/(DLRxW) | Length Width Minimum AES foot print required . for this Basic Serial design is 12.6 x 2.35 = 29.6 m2 total PES CHE ROME ar Oe Cee UMC eke AES-PIPE AES 3 mtr Lths required 8 Ith oe 5 mina requ . Digitally signed by AESC AESC Couplings required 6 ea Steve Dennis AESO AESO Offset adaptors 4 ea DN: cn=Steve Dennis, o=Chanda AESODV AES Oxgen demand vent 1 ea Enviromental, AES-IPB AES 100mm Inspection point base 2 ea @ ADVANCED ___ ou=Resign Review, ‘nawestarenoe sowtin” email=designrevie AES E AES Speed Fl: Equalis e: . qu peed Flow Equaliser ca weet ‘AES DESC Double Offset Adaptors ea septic.com.au, TOTAL SYSTEM SAND REQUIRED (Guide Only) 18 m3 c=AU Date: 2020.10.28 PLEASE email your AES CALC and Drawings to 08:37:39 +10'00' [email protected].AU_ [email protected] > The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer. > Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator. > AES pipes can be cut to length on site. They are supplied in 3 meter Iths only. 5/12 AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.