Effluent Disposal Report
5.3. Separation Distance Requirements.
One of the most important parameters to consider in the location of Land Application
Areas is the separation distances, both vertical and horizontal. Poorly or
inappropriately selected ground may contribute to the pollution of surface water and
groundwater, ponding and eutrification.
Surface Horizontal Separation distance requirements
oa
Permanent watercourses (lake/stream/river) 50m 30m 10m
Intermittent watercourses (dams/channels/weirs) 50m 30m 10m
Bore (human and or domestic consumption) 50m 30m 10m
EMT boundary unlined/open stormwater drainage 50m 30m 10m
Property boundaries/paths/walkways 4mdownslope 2 m upslope boundary
Dwellings/play areas 15m 10m spray 10m spray
4m sub/evrd | 4 m sub/evrd
Swimming pool (water edge) 6m 6m 6m
Inground watertank 15m 6m 6m
Vertical Separation distance requirements
Permanent watertable 1.2m 0.6 m 0.3m
Bedrock/hardpan 1.2m 0.6m 0.3 m
5.4 Effluent Quality
Effluent quality requirements must be confirmed with the relevant local council
before proceeding and when tested shall comply with the following;
: po Be os ne : 2 ga
Biochemical Oxygen Demand (mg/litre) 120-240 <20 <10 ~
Total Suspended Solids (mg/litre) 65-180 <30 <10
Total Nitrogen (mg/litre) 36-45 <30
Total Phosphorous (mg/litre) 6-10 <10
Thermotolerant Coliforms (organisms/100mL) <200 <10
Unearthed Geotechnical P/L. 11 Design Report 020-212