Original source · versioned page text
Effluent Disposal Report
\ ADVANCED
ENVIRO-SEPTIC dvanced Enviro-septic Design Calculator v8.8 ©
“Always The First Option”
Leader in Passive Solutions
Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary >> This design is for an ADVANCED SECONDARY system
Is this a new installation YorN >> single vent size is 80mm or 2 x 50min house vents
Namber of person a septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day
‘Number of rows required to suit site constrants >>The maximum length of a single AES pipe run is 30 meters
Infiltration surface Soll Cat as est by site/soll evaluation. CATEGORY >> Catagory may require design considerations. Ref AS1547
Design Loading Rate based on site & soll evaluation DLR (mmv/day) >> Soll con may be necessary. Ref AS1547 & Ci
Bore log depth below system Basel area >>Min depth below basel area 600mm check water table/restrictive laye
AES FOOTPRINT MUST BE LEVEL WITH TRENCH EXTENSION >>Consideration reqd for Sloping sites. Ref AS1547. refer comment.
Is this design a gravity system with no outlet filter? Y or N : _]>> A House Vent & LOW VENT required on this system
PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES
COMMENTS :-* The outcome must be important to everyone. "
- Ripping of receiving surface required in clay soll structures in Cat 4,5,6. In addition refer fo AS 1547. Always excavate & rip paralld to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for day dominated soll having dispersive or shrink/swell behaviour. Refer AS1547
- All Sloping sites special consideration and design of slope surface water and construction methods as per AS1547.
- Pambers are reminded that good construction techniques as per AS1547 are especilly important in these soll types. Refer AS1547 & AES installation Instructions
Total System load - litres / day (Q), 60 oud AES System |_E: Area
Min Length of AES pipe rows to treat loading 100 im HLth m : (L)
Number of FULL AES Pipe lengths per row 4 Iths ‘Width mW]
‘Sand 0.75 0.15
Total Capacity of AES System pipe in Litres 1696 It. | Denth « . .
Area m2 17.0 58.0
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER yy | >>Slope percentage must be 0% & infiltration footprint must be level 1
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre |
A trench design has a max of 2 rows of AKS pipes located 300mm from up slope side and centered lenght wise in the trench is better.
AES-PIPE AES 3 mtr Lihs required 8 Iths Digitally signed by
Steve Dennis
AESC AESC Couplings required 6 a DN: cn=Steve
‘AESO AESO Offset adaptors 4 a Dennis,
AESODV AES Oxgen demand vent 1 ea o=Chandar
. smvaneentf nviromental,
AES-IPB AES 100mm Inspection point base 2 ca CPANEES sen i =Resign Review,
‘AES Equ AES Speed Flow Equaliser ea ail=designrevie
W@EnVirg==2a0,|
Double Offset Adaptors ee
AES DESC le a a,
TOTAL SYSTEM SAND REQUIRED (Guide Only) 2% a3 c=AU g
PLEASE email your AES CALC and Drawings to Date: 2020.09.07
08:41:34 +10'00'
DESIGNRE [email protected] [email protected] au
> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only, Site and soit
conditions referencing the AS 1547 standard are calculated and designed by a Quallified Designer.
> Chankar Envir has no ibility for the soit evaluatic ing calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter Iths only.
AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.