ENVIRO-SEPTIC dvanced Enviro-septic Design Calculator v8.8 ©
“Always The First Option”

Leader in Passive Solutions

 

 

 

 

 

 

      

 

 

Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary >> This design is for an ADVANCED SECONDARY system
Is this a new installation YorN >> single vent size is 80mm or 2 x 50min house vents
Namber of person a septic tank outlet filter is NOT RECOMMENDED

 

Daily Design Flow Allowance Litre/Person/Day

 

 

 

 

 

 

 

 

‘Number of rows required to suit site constrants >>The maximum length of a single AES pipe run is 30 meters
Infiltration surface Soll Cat as est by site/soll evaluation. CATEGORY >> Catagory may require design considerations. Ref AS1547
Design Loading Rate based on site & soll evaluation DLR (mmv/day) >> Soll con may be necessary. Ref AS1547 & Ci
Bore log depth below system Basel area >>Min depth below basel area 600mm check water table/restrictive laye
AES FOOTPRINT MUST BE LEVEL WITH TRENCH EXTENSION >>Consideration reqd for Sloping sites. Ref AS1547. refer comment.
Is this design a gravity system with no outlet filter? Y or N : _]>> A House Vent & LOW VENT required on this system

 

PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES

 

 

COMMENTS :-* The outcome must be important to everyone. "
- Ripping of receiving surface required in clay soll structures in Cat 4,5,6. In addition refer fo AS 1547. Always excavate & rip paralld to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for day dominated soll having dispersive or shrink/swell behaviour. Refer AS1547

- All Sloping sites special consideration and design of slope surface water and construction methods as per AS1547.
- Pambers are reminded that good construction techniques as per AS1547 are especilly important in these soll types. Refer AS1547 & AES installation Instructions

 

 

 

 

 

 

 

 

 

 

   
   
  
   
 
  
   

Total System load - litres / day (Q), 60 oud AES System |_E: Area
Min Length of AES pipe rows to treat loading 100 im HLth m : (L)
Number of FULL AES Pipe lengths per row 4 Iths ‘Width mW]
‘Sand 0.75 0.15
Total Capacity of AES System pipe in Litres 1696 It. | Denth « . .
Area m2 17.0 58.0
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER yy | >>Slope percentage must be 0% & infiltration footprint must be level 1
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre |

 

 

 

 

 

 

 

 

A trench design has a max of 2 rows of AKS pipes located 300mm from up slope side and centered lenght wise in the trench is better.

   
  

   

 

 

 

AES-PIPE AES 3 mtr Lihs required 8 Iths Digitally signed by
Steve Dennis
AESC AESC Couplings required 6 a DN: cn=Steve
‘AESO AESO Offset adaptors 4 a Dennis,
AESODV AES Oxgen demand vent 1 ea o=Chandar
. smvaneentf nviromental,
AES-IPB AES 100mm Inspection point base 2 ca CPANEES sen i =Resign Review,
‘AES Equ AES Speed Flow Equaliser ea ail=designrevie
W@EnVirg==2a0,|
Double Offset Adaptors ee
AES DESC le a a,
TOTAL SYSTEM SAND REQUIRED (Guide Only) 2% a3 c=AU g
PLEASE email your AES CALC and Drawings to Date: 2020.09.07
08:41:34 +10'00'
DESIGNRE [email protected] [email protected] au

 

> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only, Site and soit
conditions referencing the AS 1547 standard are calculated and designed by a Quallified Designer.

> Chankar Envir has no ibility for the soit evaluatic ing calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter Iths only.

 

AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016

 

 
Log in to download the original file

Effluent Disposal Report.PDF · 1.1 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.