Effluent Disposal Report
5.0 DESIGN RECOMMENDATIONS We recommend the installation of an Advanced Enviro-septic™ domestic wastewater system to treat the domestic wastewater to a secondary or advanced secondary quality. We recommend the installation of a 3000 litre (min capacity) all-waste septic tank to treat the domestic wastewater to primary quality (it should be noted that the local regulatory authority may have larger minimum size requirements than those recommended). The final location of the septic tank will be determined on-site by variable consequences (e.g. finished floor levels, distances, allotment configuration and topographical constraints) over which we have little control. This final placement may necessitate the use of a pump and pump well to enable the Land Application Area to be located above the septic tank. Notwithstanding the final location of the septic tank and the Land Application Area particular attention should be paid to protecting any, or all pipework below driveways, access tracks, or such trafficable areas. The treated effluent is to be dosed into and along the Advanced Enviro-septic™ pipes. Thus receiving treated effluent and residuals in a manner and at a rate that enables their further treatment by natural in-soil stabilisation processes so that the resulting clarified carriage water is environmentally and hygienically acceptable for groundwater infiltration or evaporation and plant transpiration into the atmosphere. Pump systems (if required) shall e have a storage capacity equal to 50% of the daily flow allowance, and sufficient to match the electrical starting requirements of the irrigation pump motor e have performance characteristics that match the hydraulic characteristics of the irrigation system * have a discharge of at least 50% greater than the maximum 30-minute flow rate have a visual and audible alarm system (with muting ability) for breakdown notification e not be located adjacent to bedrooms, living rooms or recreational areas of neighbouring properties e be contained in an acoustic chamber to reduce noise emission of all equipment to a level not exceeding 40 dB (measured as fast response at a distance of 1.0m), e have incorporated into the facility pressure and/or velocity reduction fittings installed sufficiently distant above the Advanced Enviro-septic™ piping. The installed system will need capped 100mm diameter sampling ports accessible above ground to enable analysis or the performance of the system according to requirements in effect. The installed system will need Oxygen Demand Vents, as per the Advanced Enviro- septic™ requirements. Oxygen Demand Vents ensure air is drawn completely through the Advanced Enviro-septic™ piping. Unearthed Geotechnical P/L. 6 Design Report 020-212
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.