Noise and Air Quality Impact Assessment W D Milligan 31 July 2014

Attached to the e-mail MCU12/0184 - Covering email for Noise & Air Quality Impact Assessment & Traffic Engineering Report (Separately registered). A Link to the Traffic Survey video is in email..

of 78

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

 

Ridgewood

- SoundPLAN Emission Library

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Element name Unit 31.5 | 63 | 125 | 250 | 500 1 2 4 8 16 Sum

Hz Hz Hz Hz Hz_| kHz | kHz | kHz | kHz | kHz
1| Fan - North Facing dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
2| Fan - South Facing dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
3| Fan - Shed 3 dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
4| Fan - Shed 1 dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
5| Fan - Shed 2 dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
6| Fan - Shed 4 dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
7| Fan - Shed 5 dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
8| Fan - Shed 6 dB(A)/unit 61.7| 74.1] 76.8] 79.6| 86.8| 87.4| 84.0] 76.7| 68.3 91.8
9| Fan - Shed 7 dB(A)/unit 61.7| 74.1| 76.8| 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
10| Fan - Shed 8 dB(A)/unit 61.7| 74.1] 76.8] 79.6| 86.8| 87.4| 84.0| 76.7| 68.3 91.8
11| Car Lmax dB(A)/unit 57.5|_70.2| 80.4| 87.1| 90.3| 87.0] 84.0] 78.4| 69.0 94.0
12| Forklift gas average work dB(A)/unit 81.6| 85.6| 89.6/ 92.6| 95.6| 93.6] 88.6| 83.6 100.0
13| Feed delivery blower dB(A)/unit 61.2| 79.3] 99.3] 94.2| 94.4] 95.1] 93.4| 87.3 103.0
14] Truck Lmax dB(A)/unit 60.9] 77.9] 79.1] 81.9] 87.6] 90.6) 86.4] 81.4} 69.9 99.0

63.9] 79.6] 81.4] 84.9] 89.1] 87.9) 82.9] 76.9] 66.9

67.9| 78.9] 80.9] 87.9} 91.1] 88.9] 82.6] 72.6] 62.9

 

 

 

 

 

Max Winders & Associates Pty Ltd GPO Box 3137 Brisbane QLD 4000 AUSTRALIA

 

 

SoundPLAN 7.3

 
Log in to download the original file

Noise and Air Quality Impact Assessment W D Milligan 31 July 2014.pdf · 7.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.