Log in to see the plans as drawn ELECTRICAL LEGEND:
SYMBOL DESCRIPTION
NOTES:
SWITCHBOARD/METER BOX
80 PERCENT ENERGY EFFICIENT GLOBES TO ALL FIXED INTERNAL LIGHTING.
DISTRIBUTION BOARD
MINIMUM 4 STAR 'MEPS' RATED AIR CONDITIONERS WHERE FITTED. SINGLE POWER POINT - 300 above FFL
DOUBLE POWER POINT - 300 above FFL
SYMBOLS ARE INDICATIVE ONLY.
EXACT MODEL TO BUILDER'S SPECS. SINGLE POWER POINT - 1200 above FFL (UNO)
DOUBLE POWER POINT - 1200 above FFL UNO)
MECHANICAL VENTILATION TO BE IN ACCORD.
WITH THE NCC VOL 2, 3.8.5 & AS 1668.2 EX WEATHERPROOF POWER POINT
(DISCHARGE TO EXTERNAL AIR) FLUORESCENT CEILING BATTEN
LED LIGHT FITTING (ROUND)
PHOTOELECTRIC SMOKE ALARM TO NCC VOL 2, 3.7.5 & AS 3786
(MAINS POWERED & INTERCONNECTED) LED LIGHT FITTING (SQUARE)
FEATURE PENDANT
WALL MOUNTED LIGHT FITTING
RECESSED DOWN LIGHT
LEGEND:
LIGHT FITTING - FEATURE RAIL
DW DISHWASHER LIGHT SWITCH - 1000 above FFL (UNO)
PH PHONE
TV TELEVISION LIGHT SWITCH WITH DIMMER CONTROL
FR FRIDGE 2-WAY LIGHT SWITCH
RH RANGEHOOD ISOLATION SW. FOR HARD WIRED FIXTURE
EX EXTERNAL
A/C AIR CONDITIONER PH TELEPHONE POINT
HW HOTWATER TV TELEVISION POINT
MH MANHOLE
dp A/C dp
CEILING FAN - ∅1200mm - MINIMUM
PLD PANEL LIFT DOOR dp
ANT ANTENNA
CEILING FAN - ∅1200mm - MINIMUM
A/C
WITH FLUORESCENT LIGHT
S SMOKE ALARM - HARD WIRED
A/C AIR CONDITIONER UNIT
HW HOT WATER UNIT (storage)
HW HOT WATER UNIT (gas)
WIRING
FAN, LIGHT COMBINATION
FR FAN, HEAT, LIGHT COMBINATION
MW
LIGHT SENSOR
TWIN SPOT LIGHT
A/C
A/C
RH
TV
NO. ITEM
PH DW 7 DOWNLIGHT - EXTERNAL - LED
PLD dp 19 DOWNLIGHT - INTERNAL - LED
1 FAN HEAT LIGHT
2 FLURO BATTENS - INTERNAL
13 POWER POINT - DOUBLE - INTERNAL
5 POWER POINT - SINGLE - INTERNAL
1 TELEPHONE POINT
1 TELEVISION POINT
7 CEILING FAN
dp 2 SMOKE ALARM
dp
ELECTRICAL PLAN
1 : 100
© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
PAGE: SHEET SIZE: REV DRN CHK DETAILS DATE: I/WE HAVE CHECKED THE PLANS AND AGREE THAT
CLIENT: PROJECT: PROPOSED REL. RESIDENCE Supp-1 A3 THEY ACCURATELY DEPICT THE HOUSE FOR
CUSTOM PLAN ASPECT HOUSE MICHAELA VAN DER STOEP
* DS RW PRELIMINARY DRAWINGS 16/02/21
CONSTRUCTION.
JOB NUMBER: A DS RW MINOR AMENDMENTS 04/03/21
PLANS LOT 9 ON RP908915 GJGSCN190273 B AK RW SURVEY & CONTOURS ADDED 11/03/21
JOB SPECIFICATION BY BUILDER TAKES
PRECEDENCE OVER THESE PLANS.
GJ NOOSA PTY LTD BEACH FACADE 8 DANDALOO LANE SALESPERSON: C RW RW CONSTRUCTION DRAWINGS 13/03/21
DRAWING TITLE:
QLD QLD COOTHARABA, QLD CHRIS MCNEIL D RW RW JOB NUMBER CORRECTION 17/04/21 OWNER SIGNED: ............................... DATE: ..........
© COPYRIGHT EXCLUSIVE DATE: OWNER SIGNED: ............................... DATE: ..........
QBCC 1303975 TO G.J.GARDNER HOMES QBCC 1257937 ELECTRICAL PLAN 17/04/2021 BUILDER SIGNED: ............................. DATE: ..........