Log in to see the plans as drawn SELECTED INSULATION IN ACCORD.
WITH ENERGY EFFICIENCY REPORT
(WALLS, ROOF &/or CEILING)
ROOF BATTENS SIZED, SPACED &
FIXED TO ENG. DETAILS.
GANGNAIL TRUSSES TIED
DOWN TO TRUSS MANUF. WB1 WB2
ENGINEERS DETAILS PLY BRACE PANEL (900mm MIN) METAL STRAPS (1800-2700mm)
(6.0kN/m) (1.5kN/m)
COLORBOND ROOF SHEETING FIXED PITCH INDICATED ON ELEVATIONS
TO MANUF. SPECS.
TOP PLATE
CEILING BATTENS @ 450mm CTRS.
COLORBOND FASCIA &
GUTTER TOP PLATES TO ENG. DETAILS
LINTELS TO ENG. DETAILS
F.C SOFFITING. TIMBER FRAMES TO ENG. DETAILS
INDICATED ON ELEVATIONS
POWDERCOATED ALUM. WINDOW & DOOR FRAMES
NOGGINS
10mm PLASTERBOARD CEILING
STUDS
M12 BOLT THREADED ROD
BRICK SILL & WALL LINING.
CYCLONE RODS AS PER ENG. SPECS.
SELECTED FACE & SILL BRICKS.
BOTTOM PLATES TO ENG. DETAILS
M12 BOLT
SISILATION TO BUILDER'S SPECS. 100mm CONC. SLAB
°
-60
SLAB FABRIC TO ENG. SPECS.
BOTTOM PLATE
30
D.P.C. & WEEP HOLES (900 CENTRES) FLOOR
THE FINISHED SURFACE IMMEDIATELY SURROUNDING THE
BUILDINGS TO COMPLY WITH NCC VOL2, 3.1.3. FORMED VOIDS WB1 NOTES: WB2 NOTES:
A 13kN CAPACITY CONNECTION EACH END 1. TENSIONED GAL METAL STRAP (0.8mm MIN THICK, 15.2mm2 SECTIONAL AREA)
& INTERMEDIATELY @1200 CTRS - FIXED TO STUDS WITH 1, 30x2.8∅ GAL FLATHEAD NAIL &
1. M12 BOLT or - FIXED TO PLATESS WITH 3, 30x2.8∅ GAL FLATHEAD NAILS (or equiv)
2. M12 THREADED ROD BETWEEN TOP AND BOTTOM PLATE 2. FIX BOTTOM PLATE TO FLOOR FRAME OR SLAB WITH NOMINAL FIXING ONLY
3. PLYWOOD TO BE NAILED WITH 30x∅2.8 GAL FLATHEAD NAILS (AS PER AS 1684.2 TABLE 9.4)
WAFFLE POD FOOTINGS (150mm CTRS ON STUDS AND 50mm CTRS ON T/B PLATES)
(DEPTH TO ENG. SPECS)
TYPICAL SECTION - WAFFLE SLAB
1 : 25
© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
PAGE: SHEET SIZE: REV DRN CHK DETAILS DATE: I/WE HAVE CHECKED THE PLANS AND AGREE THAT
CLIENT: PROJECT: PROPOSED REL. RESIDENCE 9 A3 THEY ACCURATELY DEPICT THE HOUSE FOR
CUSTOM PLAN ASPECT HOUSE MICHAELA VAN DER STOEP
* DS RW PRELIMINARY DRAWINGS 16/02/21
CONSTRUCTION.
JOB NUMBER: A DS RW MINOR AMENDMENTS 04/03/21
PLANS LOT 9 ON RP908915 GJGSCN190273 B AK RW SURVEY & CONTOURS ADDED 11/03/21
JOB SPECIFICATION BY BUILDER TAKES
PRECEDENCE OVER THESE PLANS.
GJ NOOSA PTY LTD BEACH FACADE 8 DANDALOO LANE SALESPERSON: C RW RW CONSTRUCTION DRAWINGS 13/03/21
DRAWING TITLE:
QLD QLD COOTHARABA, QLD CHRIS MCNEIL D RW RW JOB NUMBER CORRECTION 17/04/21 OWNER SIGNED: ............................... DATE: ..........
© COPYRIGHT EXCLUSIVE DATE: OWNER SIGNED: ............................... DATE: ..........
QBCC 1303975 TO G.J.GARDNER HOMES QBCC 1257937 TYPICAL SECTION & DETAILS 17/04/2021 BUILDER SIGNED: ............................. DATE: ..........