                                                                                                                                 G E N E R A L                                                      N O T E S
GENERAL             NOTES                                                                      SITE        NOTES                                                                         ROOFWATER                  DRAINAGE                                                       MANUFACTURES                            SPECIFICATIONS
DO NOT SCALE OFF DRAWINGS, ONLY USE FIGURED DIMENSION. BUILDER IS TO VERIFY ALL                BUILDER TO CONFIRM LOCATIONS OF ALL EXISTING SERVICES BELOW & ABOVE GROUND LEVEL          ALL ROOFWATER DRAINAGE SYSTEMS MUST BE CONNECTED TO A STORMWATER DRAINAGE                 ALL BUILDING PRODUCTS & MATERIALS THAT ARE USED ON SITE MUST BE STORED CORRECTLY
DIMENSIONS PRIOR TO COMMENCING AND WORK/CONSTRUCTION & ORDERING OF MATERIALS.                  ON & ADJACENT TO THE SITE, PRIOR TO ANY BUILDING WORKS.                                   SYSTEM COMPLYING WITH NCC 2019 BCA - VOL 2, PART 3.1.3 DRAINAGE & AUSTRALIAN              AS PER MANUFACTURERS SPECIFICATIONS. REFER TO MANUFACTURERS SPECIFICATIONS FOR
BUILDER TO CONFIRM RL'S ON SITE PRIOR TO COMMENCEMENT OF EARTHWORKS.                                                                                                                     STANDARD AS/NZ 3500.                                                                      MATERIAL AND PRODUCTS RECOMMENDED TO USE FOR ALL SITES THAT ARE LOCATED WITHIN
                                                                                               THE FINISHED SURFACE IMMEDIATELY SURROUNDING THE BUILDING FOR A MINIMUM WIDTH OF                                                                                                    PROXIMITY TO SALT ENVIRONMENTS.
ALL WORK PERFORMED SHALL ADHERE TO THE MINIMUM STANDARDS SETOUT & PRESCRIBED                   1000mm, SHALL BE PROVIDED WITH A MINIMUM SLOPE OF 1 in 20 AWAY FROM THE BUILDING          THE ROOF DRAINAGE SYSTEM MUST BE PROVIDED WITH AN OVERFLOW TO PREVENT THE
BY THE RELEVANT AUSTRALIAN STANDARDS, THE NATIONAL CONSTRUCTION CODE'S BUILDING                TO AN APPROVED DRAINAGE SYSTEM AS PER NCC 2019 BCA - VOL 2, PART 3.1.3.3 SURFACE          BACKFLOW OF WATER INTO THE BUILDING.
CODE OF AUSTRALIA, AND THE REQUIREMENTS & REGULATIONS SETOUT BY ANY FEDERAL,                   WATER DRAINAGE.
STATE & REGIONAL GOVERMENT.                                                                                                                                                              THE AREA SPECIFIC RAINFALL INTENSITY MUST BE SELECTED FROM NCC 2019 BCA - VOL 2,          DRIVEWAY                      &     PATH      NOTES
                                                                                               SURFACE DRAINAGE IS TO DISCHARGE EVENLY WITHIN THE SITE & WITHOUT NUISANCE TO             PART 3.5.3.1, FROM AUSTRALIAN STANDARD AS/NZ3500.3 OR FROM THE BUREAU OF
ALL BUILDING WORKS TO COMPLY WITH LOCAL AUTHORITIES EROSION AND SEDIMENT CONTROL               ADJOINING PROPERTIES.                                                                     METEOROLOGY 2016 RAINFALL DATA.                                                           ALL SITE PAVING TO BE CONSTRUCTED IN ACCORDANCE WITH THE PUBLICATIONS
STANDARDS. ALL SEDIMENT FENCING TO BE ERECTED ON SITE PRIOR TO COMMENCEMENT OF                                                                                                                                                                                                     CEMENT, CONCRETE & AGGREGATE AUSTRALIA - GUIDE TO CONCRETE HOUSING 2007, PATHS
WORK.                                                                                          ALL SUBFLOOR AREAS MUST BE GRADED TO AVOID THE PONDING OF WATER BENEATH THE               GUTTERS & DOWNPIPES MUST BE SELECTED FROM NCC 2019 BCA - VOL 2, PART 3.5.3.5              & DRIVEWAYS & RESIDENTIAL CONCRETE DRIVEWAYS & PATHS - JULY 2005.
                                                                                               BUILDING.                                                                                 TABLE 3.5.3.2 OR FROM AUSTRALIAN STANDARD AS/NZ3500.3.
ALL PLUMBING & DRAINAGE TO COMPLY WITH STANDARD SEWERAGE BY-LAWS &                                                                                                                                                                                                                 THE AREA BENEATH & ADJACENT TO DRIVEWAYS & PATHS TO BE CLEARED OF ALL TOPSOIL &
REQUIREMENTS OF LOCAL AUTHORITY.                                                               CUT & FILL BATTERS ARE NOT TO EXCEED A MAXIMUM SLOPE AS PER NCC 2019 BCA - VOL            EAVES GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 in 500 WITH SUPPORT             ORGANIC MATTER.
                                                                                               2, PART 3.1.1 EARTHWORKS TABLE 3.1.1.1 FOR THE SITE SPECIFIC SOIL TYPE. REFER TO NCC      BRACKETS AT 1200mm MAXIMUM CENTRES.
BUILDER TO CONFIRM EXACT SITING AND ORIENTATION PRIOR TO CONSTRUCTION SETOUT. ALL              2019 BCA - VOL 2, PART 3.2.2.4 FOR SLAB EDGE SUPPORT ON SLOPING SITES.                                                                                                              PROVIDE A COMPACTED & LEVELLED LAYER OF 20mm MINIMUM SAND: & AN OPTIONAL 0.2UM
BUILDING SETOUT AND CONFIRMATION OF SETBACKS AND HEIGHT TO BE CARRIED OUT BY A                                                                                                           BOX GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 in 100, IN ACCORDANCE             POLYETHYLENE MOISTURE BARRIER MAY BE PROVIDED UNDER THE SLAB IN SALINE AREAS,
LICENSED SURVEYOR. NO FOOTING, OR WALL TO ENCROACH THE TITLE BOUNDARY.                         TIMBER RETAINING WALLS TO HAVE 1000mm MAXIMUM HEIGHT. PROVIDE 65mm DIA. AGG.              WITH AUSTRALIAN STANDARD AS/NZ3500.3.                                                     LAPPED & TAPED 200mm AT JOINTS.
                                                                                               DRAINS WITH GRANULAR BACKFILL. RETAINING WALLS & DRAINAGE SYSTEMS TO BE
ALL WET AREAS TO BE CONSTRUCTED IN ACCORDANCE WITH NCC 2019 BCA - VOL 2, PART 3.8.1            WHOLLY CONTAINED ON THE SUBJECT SITE. RETAINING WALLS GREATER THAN 1000mm IN              THE WIDTH OF VALLEY GUTTERS SHALL BE IN ACCORDANCE WITH AUSTRALIAN STANDARD               ALL PATHS & DRIVEWAYS SHALL HAVE A MINIMUM FALL OF 1 in 100 (1%).
WET AREAS AND EXTERNAL WATERPROOFING.                                                          HEIGHT SHALL BE DESIGNED BY THE STRUCTURAL ENGINEER.                                      AS/NZ3500.3 & BUILDING CODE OF AUSTRALIA PART 3.5.2. REFER TO ROOF SHEETING
                                                                                                                                                                                         MANUFACTURERS SPECIFICATIONS FOR LIMITATIONS ON SHEET OVERHANGS INTO VALLEY               THE MAXIMUM GRADE OF PAVEMENTS SHALL NOT EXCEED 1 in 5 (20%). WHERE GRADES ARE
WATER CLOSETS WITH DOOR CIRCULATION SPACES LESS THAN 1.2m FROM THE HINGE OF THE                BOUNDARY FENCES, INCLUDING HEIGHT OF ANY RETAINING WALLS UNDER, MUST NOT EXCEED           GUTTERS. THE MAXIMUM ROOF CATCHMENT AREA FOR VALLEY GUTTERS IS 20sq.m.                    NEAR THE MAXIMUM, A TRANSITION ZONE AT EITHER END MAY BE REQUIRED. REFER TO
DOOR MUST BE PROVIDED WITH LIFT-OFF HINGES THAT ALLOW THE DOOR TO BE REMOVED                   2000mm IN HEIGHT ABOVE EXISTING GROUND LEVEL. REFER TO LOCAL AUTHORITY                    VALLEY GUTTERS ON ROOF PITCHED LOWER THAN 12.5 DEGREES MUST BE DESIGNED AS BOX            BUILDING CODE OF AUSTRALIA - VOLUME 1 PART D2.10 FOR GRADES TO REQUIRED EXIT RAMPS.
WHEN IN THE CLOSED POSITION IN ACCORDANCE WITH NCC 2019 BCA - VOL 2, PART 3.8.3.3              REGULATIONS PRIOR TO COMMENCING ANY WORKS & SEEK ANY REQUIRED APPROVALS.                  GUTTERS.
CONSTRUCTION OF SANITARY COMPARTMENTS . WATER CLOSETS TO HAVE A MINIMUM CLEAR                                                                                                                                                                                                      ALL DRIVEWAYS, PATHS & CROSSOVERS BETWEEN THE PROPERTY BOUNDARY & THE KERBLINE
WIDTH OF 900mm.                                                                                                                                                                          DOWNPIPES MUST SERVE NOT MORE THAN 12 METRES OF GUTTER LENGTH FOR EACH                    ARE DESIGNED TO BE CONSTRUCTED AS PER THE ALOCAL AUTHORITY REQUIREMENTS.
                                                                                               TERMITE              PROTECTION                                                           DOWNPIPE WHICH MUST BE LOCATED AS CLOSE AS POSSIBLE TO VALLEY GUTTERS.
PROVIDE APPROVED SMOKE ALARMS INSTALLED IN ACCORDANCE WITH NCC 2019, BCA - VOL 2,
PART 3.7.5 SMOKE ALARMS AND EVACUATION LIGHTING , BE INTERCONNECTED & TO COMPLY                ALL NEW BUILDING WORK AND/OR ALTERATIONS OF EXISTING BUILDING WORK IS TO BE               EAVES GUTTERS MUST BE PROVIDED WITH AN OVERFLOW SYSTEM WHERE DOWNPIPES ARE
AUSTRALIAN STANDARD AS 3786.                                                                   TERMITE PROTECTED VIA PHYSICAL &/ CHEMICAL BARRIERS AS PER NCC 2019 BCA - VOL 2,          LOCATED MORE THAN 1200mm FROM A VALLEY GUTTER.
                                                                                               PART 3.1.4.3 TERMITE MANAGEMENT SYSTEMS, TABLE 3.1.4.1 ACCEPTABLE TERMITE
ALL GLAZING TO COMPLY WITH NCC 2019 BCA - VOL 2, PART 3.6 GLAZING & MUST BE                    MANAGEMENT SYSTEMS AND COMPONENTS , AS 3660.1 TERMITE MANAGEMENT NEW
DESIGNED FOR THE WIND LOADS SPECIFIC TO THE BUILDING.                                          BUILDING WORK & AS 3660.2 TERMITE MANAGEMENT IN AND AROUND EXISTING BUILDINGS
                                                                                               AND STRUCTURES. A 75mm INSPECTION ZONE ON ALL NEW SLABS AS REQUIRED BY AS                 BRANDING               OF      STRUCTURAL                   PLYWOOD
ALL STAIRS & STEPS ARE DESIGNED & ARE TO BE CONSTRUCTED IN ACCORDANCE WITH NCC                 3660.1.
                                                                                                                                                                                         EACH SHEET OF STRUCTURAL GRADE PLYWOOD SHALL HAVE THE FOLLOWING INFORMATION
2019 BCA - VOL 2, PART 3.9.1 STAIRWAY AND RAMP CONSTRUCTION .
                                                                                               A DURABLE NOTICE IS REQUIRED AND MUST BE INSTALLED IN A PROMINENT LOCATION SUCH           LEGIBLY AFFIXED THEREON BY THE MANUFACTURER AT THE POINT OF MANUFACTURE, AT
                                                                                               AS THE METER BOX & IS TO BE PERMANENTLY FIXED. THE INFORMATION TO BE DISPLAYED            LEAST ONCE:
ALL BALUSTRADES & HANDRAILS REQUIRED SHALL BE 1000 MINIMUM ABOVE FINISHED FLOOR
LEVEL (ie TOP OF TILES, CARPET ETC) & HAVE NO OPENINGS GREATER THAN 125mm, IN                  ON THE NOTICE IS AS PER NCC 2019 BCA - VOL 2, PART 3.1.4.4 DURABLE NOTICE.
                                                                                                                                                                                         1.       THE MANUFACTURERS NAME OR REGISTERED MARK,
ACCORDANCE WITH NCC 2019 BCA - VOL 2, PART 3.9.2 BARRIERS AND HANDRAILS .                                                                                                                2.       THE WORD 'STRUCTURAL' OR PRODUCT DESCRIPTION
                                                                                               THEREAFTER THE OWNER TAKES ONTHE RESPONSIBILITY TO ORGANISE REGULAR INSPECTIONS
                                                                                               WHICH MUST BE CARRIED OUT BY A QBCC-LICENSED CONTRACTOR WITH THE APPROPRIATE              3.       REFERENCE TO THE STANDARD ie AS/NZ2269
REFER TO STRUCTURAL ENGINEERS DRAWINGS & SPECIFICATIONS FOR SOILS REPORTS, FOOTING                                                                                                       4.       THE GRADE OF OUTER PLIES (FACE FIRST,BACK LAST) eg CC CD or DD
& SLAB DOCUMENTATION & OTHER REQUIRED STRUCTURAL DOCUMENTATION.                                TERMITE MANAGEMENT LICENCE TO ENSURE TERMITES HAVE NOT BRIDGED THE BARRIER. IT IS
                                                                                               RECOMMENDED THAT INSPECTIONS BE AT LEAST EVERY 12 MONTHS, OR MORE OFTEN IN HIGH
                                                                                               RISK AREAS. IT SHALL ALSO BE ADVISED THAT CAUTION BE TAKEN TO ENSURE THAT ALL             WHERE NON-STANDARD VENEER GRADES ARE USED, AS PERMITTED IN BUILDING CODE OF
                                                                                               PHYSICAL TERMITE BARRIERS BE CLEAR OF GARDEN BED &/OR SOIL BUILD UP & THAT ANY            AUSTRALIA PART 3.4 CLAUSE3.4.1(c), BRANDING SHALL INCLUDE A DESCRIPTOR THAT NON-
SUBFLOOR               VENTILATION                                                                                                                                                       STANDARD VENEER QUALITY HAS BEEN USED IN THE PLYWOOD ASSEMBLY;
                                                                                               CHEMICAL BARRIERS INSTALLED REMAIN UNDISTURBED.
PROVIDE SUBFLOOR VENTILATION TO THE MINUMUM STANDARD AS PER NCC 2019 BCA - VOL 2,
                                                                                                                                                                                         THIS REQUIREMENT MAY BE MET BY REFERENCE TO A PRODUCT NAME OR DESCRIPTION THAT
PART 3.4.1 SUBFLOOR VENTILATION. IN ADDITION TO THE MINIMUM SUBFLOOR SPACE, THE
SUBFLOOR SPACE MUST;
                                                                                               BRICK/BLOCKWORK                            ARTICULATION                                   REFERENCES THE NON-STANDARD VENEER QUALITY IN THAT PRODUCTS SPECIFIC
                                                                                               JOINTS                                                                                    MANUFACTURING SPECIFICATION,
- BE CLEARED OF ALL BUILDING DEBRIS AND VEGETATION
- HAVE THE GROUND BENEATH THE SUSPENDED FLOOR GRADED IN ACCORDANCE WITH 3.1.3.3                                                                                                          1.        THE BOND TYPE OF THE GLUE LINE ie TYPE A BOND
- CONTAIN NO DEAD AIR SPACES                                                                   BRICKWORK ARTICULATION JOINTS ARE TO BE INSTALLED AT LOCATIONS OUTLINED IN NCC            2.        AN INDICATION OF THE STRESS GRADE OF THE SHEET eg F7
- HAVE OPENINGS AS PER NCC 2019 BCA - VOL 2, FIGURE 3.4.2                                      2019 BCA - VOL 2, PARK 3.3.5.13 VERTICAL ARTICULATION JOINTS. BOTH BRICK &                3.        THE PANEL CONSTRUCTION CODE eg 17-24-7 (I.D. CODE)
- BE GRADED AS PER NCC 2019 BCA - VOL 2, PART 3.1.3.3 SURFACE WATER DRAINAGE .                 BLOCKWORK ARTICULATION JOINTS ARE TO BE IN AS PER AS 4773.2 MASONRY IN SMALL              4.        IF IMMUNISED OR PRESERVATIVE TREATED, BRANDING IN ACCORDANCE WITH
THE CLEARANCE BETWEEN THE GROUND SURFACE & THE UNDERSIDE OF THE FLOOR, MUST BE                 BUILDINGS CONSTRUCTION OR AS PER ENGINEER.                                                          AS/NZS1604.3
400mm, OR AS PER FIGURE 3.4.3a SUBFLOOR CLEARANCE REQUIREMENTS.                                                                                                                          PLYWOOD MUST BE BRANDED WITH THE APPROVED EWPAA PRODUCT CERTIFICATION STAMP
PROVIDE SUBFLOOR VENTILATION TO A MINIMUM AREA AS PER NCC 2019 BCA - VOL 2, PART                                                                                                         AS WELL AS THE JAS-ANZ (JOINT ACCREDITATION SCHEME OF AUSTRALIA & NEW ZEALAND)
3.4.1.1 SUBFLOOR OPENINGS.                                                                                                                                                               MARK.



AAA Design & Development Pty Ltd                                                                         No.                        Description                               Date            Mat Deighton                                                                    APPROVED                    General Notes

34/13 Norval Court, MAROOCHYDORE, QLD 4558                                                                                                                                                    14 Orealla Cres,                                                                                            Project number      D139-01                          Revision
Tel/Fax:       (07) 5479 6747                                                                                                                                                                 SUNRISE BEACH, QLD 4567                                                                                     Date             24/08/2022    3951- A118
Mob:           0422 039 247
                                                                    design                                                                                                                                                                                                                               Drawn by                R.S.                           A
email:         [email protected]                                      Development Pty Ltd                                                                                             PROPOSED DUAL OCCUPANCY                                                      For & on behalf of AAA
                                                                                                                                                                                                                                                                        Design & Development Consulting   Checked by            D.L.T. Scale @A3                1 : 100
                                                                                                           A    PRELIMINARY                                                 24/08/2022
Log in to download the original file

Attachment 1 - Amended Proposal Plans.pdf · 11.6 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.