Council archive · source document
Response to code requirements REC17/0013
r
Compliancewith PSP24will be considered
as part of Council'sassessment of the
plumbing and drainage application.
017 Essential public utilities are available and
maintain their function during flood events up to a 517.1 Components of the infrastructure that
1% AEP(l:100 year ARt) flood event.
are likely to fail or may result in contamination
are-
a) located above the level of a 1% AEP
(1:100 year ARt) flood event; or
b) designed and constructed to exclude
water inundation or infiltration and resist
hydrostatic and hydrodynamic forces as
Electricity supply infrastructure a result of inundation.
018 Uses and works maintain a safe distance from
electrical infrastructure including substations, 518.1 Building footprints are situated clear
overhead power lines, power poles and of any power easements on-site;
transformers. AND
518.2 Building footprints are not less than
SOmfrom an existing fenced electricity
substation.
14.190 Earthworks and stormwater mana ement
019 Stormwater run-off is managed so as not to No solution provided
cause any adverse impacts on the buin or natural
environment including changes in quality. quantity
or location of stormwater dischar es.
020 Filling or excavation only Occurs where it does No prescribed solution.
not adversely impact on-
a) watercourses. drainage lines and wetlands; or
b) vegetation on land identified on Biodiversity
Overlay Maps OM1.1-0M9.1; or
c) water levels on properties elsewhere.
14.191 Landsca in and visual ameni
021 Land development responds to the distinctive
landscape character of the site by utilising the 521.1 The natural landform and landscape
natural features of the site. which include- are not modified to accommodate the
a) watercourses and drainage lines; development.
b) significant trees;
c) understorey vegetation;
d) rock outcrops; and
e views.
022 Native vegetation. including individual mature
trees are retained, protected, maintained and 522.1 Buffers of existing native vegetation
Supplemented, with particular consideration given around site boundaries and environmentally
to-- sensitive areas are retained and reinforced
a) roadsides; through additional planting;
b) the amen~y of adjoining land uses; and AND
c) the protection of environmentally sensitive 522.2 For reconfiguring in the Rural Zone
areas. and Rural Settlement Zone-
a) a 10m landscaped buffer area is
provided along road frontages;
b) clearing and disturbance to vegetation
is minimised around road works, laying
of services and utilities and construction
" PSP1Plans.
Master identifies information that may be requested by Council including Stormwater Management Plans and Stormwater
14-177
Reconfiguring a lot Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.