                                                                                  Compliancewith PSP24will be considered
                                                                                  as part of Council'sassessment of the
                                                                                  plumbing and drainage application.
               017 Essential public utilities are available and
               maintain their function during flood events up to a            517.1 Components of the infrastructure that
               1% AEP(l:100 year ARt) flood event.
                                                                              are likely to fail or may result in contamination
                                                                              are-
                                                                             a)     located above the level of a 1% AEP
                                                                                    (1:100 year ARt) flood event; or
                                                                             b)    designed and constructed to exclude
                                                                                   water inundation or infiltration and resist
                                                                                   hydrostatic and hydrodynamic forces as
            Electricity supply infrastructure                                      a result of inundation.
            018 Uses and works maintain a safe distance from
           electrical infrastructure including substations,                  518.1 Building footprints are situated clear
           overhead power lines, power poles and                             of any power easements on-site;
           transformers.                                                 AND
                                                                         518.2 Building footprints are not less than
                                                                         SOmfrom an existing fenced electricity
                                                                         substation.
          14.190 Earthworks and stormwater mana ement
          019 Stormwater run-off is managed so as not to                 No solution provided
          cause any adverse impacts on the buin or natural
          environment including changes in quality. quantity
          or location of stormwater dischar es.
          020 Filling or excavation only Occurs where it does           No prescribed solution.
          not adversely impact on-
          a)      watercourses. drainage lines and wetlands; or
          b)      vegetation on land identified on Biodiversity
                  Overlay Maps OM1.1-0M9.1; or
       c)         water levels on properties elsewhere.

       14.191 Landsca in and visual ameni
        021 Land development responds to the distinctive
       landscape character of the site by utilising the                521.1 The natural landform and landscape
       natural features of the site. which include-                    are not modified to accommodate the
      a) watercourses and drainage lines;                              development.
      b) significant trees;
      c) understorey vegetation;
      d) rock outcrops; and
      e    views.
     022 Native vegetation. including individual mature
     trees are retained, protected, maintained and                     522.1 Buffers of existing native vegetation
     Supplemented, with particular consideration given                around site boundaries and environmentally
     to--                                                             sensitive areas are retained and reinforced
     a)        roadsides;                                             through additional planting;
     b)        the amen~y of adjoining land uses; and                AND
     c)        the protection of environmentally sensitive           522.2 For reconfiguring in the Rural Zone
               areas.                                                and Rural Settlement Zone-
                                                                     a) a 10m landscaped buffer area is
                                                                         provided along road frontages;
                                                                     b) clearing and disturbance to vegetation
                                                                         is minimised around road works, laying
                                                                        of services and utilities and construction
    " PSP1Plans.
    Master identifies information that may be requested by Council including Stormwater Management Plans and Stormwater




                                                           14-177
                                                  Reconfiguring a lot Code

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Response to code requirements REC17_0013.pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.