                                                    3.    the community infrastructure will not be
                                                          adversely affected by landslide activity
                                                          originating from other land, including land
                                                          above the site; and
                                                    4.    development of the site will not increase the
                                                          risk of landslide activity on other land.
 PO3                                                AO3.1                                               Complies.
 Development, including associated access, is       Buildings present no more than two storeys at any The proposed development is for a swimming pool.
 designed and constructed to:                       one point when viewed from the road or other public
                                                    space.
             1. be responsive to the natural        AO3.2                                                           Complies.
                topography and constraints          Buildings and associated accesses are not                       Existing building and accesses are retained.
                imposed by the slope;               constructed on land with a slope greater than 25%.
            2. retain the natural landforms,
                landscape                           AO3.3                                                           Complies.
                character, vegetation, including    No additional lots intended to provide house sites              No additional lots intended to provide house sites
                the visual amenity of hill slopes   are created on land with a slope of 25% or greater.             are created.
                and ridgelines;
            3. visually integrate into the          AO3.4                                                           Complies.
                streetscape and the natural         Buildings are designed to follow the natural                    Existing buildings will be retained and no
                surrounds; and                      landform rather than modify it.                                 modification of landform.
            4. ensure buildings and structures      Editor's note- Designs that step down the slope using
                are not visually obtrusive,         split level construction or elevated construction on
                particularly from ridgelines,       suspended floors are a preferred alternative to standard
                                                    slab on ground construction reliant on cut and fill of sites.
                public open spaces, scenic
                routes and other critical           AO3.5                                                           Complies.
                vantage points, outside the site.   The extent of filling or excavation is revegetated              There is no filling and excavating related to the
  2524a0f8-a214-4048-aa0a-299604ce8d31              immediately following completion of the works.                  proposal

                                                    AO3.6                                                           Complies.
                                                    Any building, including any associated car parking              The existing dwelling unit will be retained.
                                                    structure:-
                                                    1. has a maximum undercroft height at the
                                                          perimeter of the building of 3 metres
                                                          above ground level; or
                                                    2. incorporates landscape screening for the full
                                                          height of any undercroft higher than 3 metres
                                                          above ground level at the perimeter of
                                                          the building.
                                                    Editor's note- Vertical battens are also useful to
                                                    enclose the undercroft area.
                                                    AO3.7                                                   Complies.
                                                    On sloping sites roof lines are generally parallel with The existing roof pitch will not be altered.
                                                    contours of the land and roof pitch does not exceed
                                                    15 degrees.
 PO4                                                AO4.1                                                           Not Applicable.
 Development on sloping sites provides safe and     Driveways are not steeper than 20% for more than                The proposed development is for a pool.
 efficient access for vehicles and pedestrians      20 metres or one quarter of their length, whichever
                                                    is the lesser, and not steeper than 25% in any
                                                    location.
                                                    AO4.2                                                           Not Applicable
                                                    Vehicle turning areas are provided at the end of                The proposed development is for a pool.
                                                    driveways so that it is not necessary to reverse up
                                                    or down driveways.
                                                    AO4.3                                                Not Applicable.
                                                    Where a driveway is steeper than 20% in any part, it The proposed development is for a pool.
                                                    is provided with a slip-resistant surface.




Planning Partnerships                               www.pplan.net.au                                TEL 07 3707 6675           PO Box 340, Hamilton Central, QLD 4007

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment A - GIA Cover letter - 1.36 Ventura Street, Sunrise Beach.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.