Figure 2-4: DRAINS model for existing catchment This assumption is considered appropriate as the existing site is currently developed with a single dwelling and associated impervious area consistent with low density residential conditions. The relevant DRAINS catchment inputs are detailed in Figure 2-5. Figure 2-5: DRAINS catchment inputs The pre-development flow rates for various AEP were calculated using DRAINS. The results are summarized in Table 2-3. Table 2-3: DRAINS results for existing catchment AEP % 63.2% 50% 20% 10% 5% 2% 1% Pre-Development Flow (m³/s) 0.011 0.013 0.020 0.024 0.028 0.034 0.038 A comparative assessment was conducted to evaluate the variance between DRAINS results and the Rational Method calculations. The differences between the two methodologies are presented in Table 2-4. 17 BOTTLEBRUSH AVENUE, NOOSA HEADS 7 January 2026 P a g e |9 Stormwater Management Plan Client Reference: P0433-25-001 Prepared for Made Capital PTY LTD